Ultrasonic sensor
diffuse mode sensor
RU200-CK40-LIU2N8X2T-H1151
■ Separate transducers for transmitter
and receiver
■ Rectangular housing 40 x 40 mm
■ Connection via M12 x 1 male
■ Teach range adjustable via button
■ Blind zone: 5 cm
■ Range: 200 cm
■ Resolution: 1 mm
■ Sonic cone angle: 60°
■ 1 x switching output, NPN
■ NO/NC programmable
■ 1 x analog output, 4..20mA/ 0..10 V
Type designation RU200-CK40-LIU2N8X2T-H1151
Ident-No. 1610058
Repeat accuracy
Ambient temperature 0…+70 °C
Operating voltage 15…30 VDC
Residual ripple
DC rated operational current
No-load current I
Residual current
Output function 5-wire, NO/NC contact, NPN
Short-circuit protection yes/ Cyclic
Voltage drop at I
Wire breakage/Reverse polarity protection yes/ yes
Design Rectangular, CK40
Dimensions 67 x 40 x 40 mm
Housing material Plastic, PBT-GF30-V0
Electrical connection Connector, M12 × 1
Protection class IP40
Switching state LED yellow
0
e
ð 0.25 % of full scale
ð 10 % U
ss
ð 150 mA
ð 50 mA
ð 0.1 mA
ð 2.5 V
Wiring Diagram
Functional principle
Ultrasonic sensors capture a multitude of objects contactless and wear-free with ultrasonic waves. It does not matter whether the object is transparent or opaque, metallic or nonmetallic, firm, liquid or powdery. Even environmental conditions such as spray, dust or rain
hardly affect their function.
Sonic Cone
Edition • 2017-01-06T17:55:29+01:00
1 / 3 TURCK Inc.
Ultrasonic sensor
diffuse mode sensor
RU200-CK40-LIU2N8X2T-H1151
Setting the limits
The ultrasonic sensor has an analog and a switching
output with teachable measuring and switching range.
Teaching is possible via Easy-Teach adapter or with the
buttons at the sensor. The green and yellow LED indi-
cate whether the sensor has detected an object.
Various functions such as single switchpoint, window
mode or reflection mode to a fixed target can be taught.
Further information is described in the operating in-
structions. How to set the window mode is described
below. The limits of the window may be selected freely
within the detection range.
Easy-Teach
ñConnect teach adapter TX1-Q20L60 between sensor
and connection cable
ñFor the first limit value, place object accordingly
ñ Press and hold the select button for output 1 or 2 for
2 or 8 s against Gnd
ñ Press and hold the select button for 8 s against Gnd
to teach the first limit value.
ñFor the second limit value, place object accordingly
ñPress and hold button for at least 2 s against Gnd
Teach-Button
ñFor the first limit value, place object accordingly
ñ Press and hold button 1 to select output 1 or 2 for 2
or 8 s against Gnd
ñ Press and hold button 1 for at least 8 s
ñFor the second limit value, place object accordingly
ñ Press and hold button 1 for at least 2 s
LED response
Successful teaching is indicated by a fast flashing
green LED. Thereafter, the sensor automatically runs in
normal operating mode. Unsuccessful teaching is indi-
cated by the LED flashing alternately green and yellow.
In normal operating mode both LEDs signal the switch-
ing state of output 1.
ñgreen: object is in the detection range but not in the
switching range
ñ yellow: object is in the switching range
ñoff: object is outside the detection range or signal loss
Edition • 2017-01-06T17:55:29+01:00
2 / 3 TURCK Inc.