Turck Rectangular Inductive Sensor Part Numbering Designation

Rectangular Inductive Sensor Part Number Key
B i 15 - Q 20 - A P 6 X2 Wiring Option* Special Option Code**
Mounting
Principle of Operation
i = inductive
Rated Operating Distance (mm)
Sensing Characteristics
S = side sensing on Q10S sensor U = Uprox® Sensor
Housing Style Rectangular
K = smooth Q = metal or plastic, various rectangular styles
Limit Switch
CA = Stubby®, short aluminum housing, connector CK = Stubby, short plastic housing, connector CP = Combiprox®, plastic housing, terminal chamber base with removable sensor
Housing Height (mm)
NOTE:
Part number keys are to assist in identication only. Verify new part numbers with factory; some congurations are not possible.
Secondary Housing Modier
SR = straight terminal chamber
Output Function
A = normally open (N.O.) F = connection programmable (N.O. or N.C.) V = complementary outputs: one N.O., one N.C. Y0 = NAMUR output, requires switching amplier Y1 = NAMUR output, requires switching amplier/ATEX approved
Number of LEDs
(blank) = no LEDs X = 1 LED X2 = 2 LEDs
Voltage Range AC/DC: (No SCP**)
3 = 20-250 VAC, 10-300 VDC 31 = 20-250 VAC, 10-300 VDC, plastic barrel
AC/DC: (Latched SCP)
30 = 20-250 VAC, 10-300 VDC 400 mA 32 = 20-250 VAC, 10-300 VDC 400 mA
DC:
4 = 10-65 VDC, polarity protected, pulsed SCP** 6 = 10-30 VDC, polarity protected, pulsed SCP **SCP = short-circuit and overload protection
Output
D = 2-wire DC (transistor output) DZ = 2-wire AC/DC, (power MOSFET output) N = NPN transistor (current sinking) P = PNP transistor (current sourcing) Z = 2-wire AC or 2-wire AC/DC
Rectangular Inductive Sensors
Wiring Options*
A. Connectorized Sensor
We reserve the right to make technical alterations without prior notice.
Connector Family
B1 = Minifast®, Metal, Male B2 = Minifast, Plastic, Male B3 = Microfast®, Metal, Male H1 = Eurofast®, Metal or Plastic, Male V1 = Picofast®, Metal, Male V2 = Picofast, Snap and M8x1, Male (Q08 Only)
Connector/Sensor Transition
1 = straight
B. Potted Cable
Special Option Codes**
Option Code Example:
/S34 = Weld Field Immune /S97 = -40 °C (-40 °F) Operating Temperature /S100 = +100 °C (+212 °F) Operating Temperature
Bi15 - Q20 - AN6X2 - H1 1 4 1
Wiring Conguration Example:
1 = Standard 3 = N.C. DC Output on Pin 4 (for US)
Number of Pins
Bi15 - Q20 - AN6X2 - 7M
Cable Length
Blank = 2 meter cable 7M = 7 meter cable
Bi - 5 - Q08 - AN6XS /S34
/S1590 = CK/CA40 sensors with Weldguard laminate /S1591 = CA40 sensors with Weldguard and Armorguard
Turck Inc.
A2