Pressure Transmitter
with current output (2-wire)
PT510-7500PSIG-13-LI3-H1131
Type designation PT510-7500PSIG-13-LI3-H1131
Ident-No. 6831580
Pressure range
Relative pressure 0…517 bar rel.
0…7500 psi
0…51.7 MPa
Admissible overpressure
Burst pressure
Response time < 2 ms, typ. 1 ms
ð 1500 bar
ï 2500 bar
■ Compact and robust design
■ Pressure connection with integrated
peak pressure aperture
■ Accuracy hardly affected by tempera-
ture within entire range -40…+125°C
■ Excellent EMC properties
■ Pressure range 0…7500 psi rel.
Wiring Diagram
Functional principle
The pressure transmitters of the PT …-3 series operate with a stainless steel measuring
cell. Depending on the output type, the processed signal is available either as 4…20mA
(2-wire) or 0…10V (3-wire) analog output.
Power supply
Operating voltage 8…33 VDC
Current consumption
Short-circuit/reverse polarity protection yes / yes
Protection type and class IP67 / III
Outputs
Output 1 Analog output
Analog output
Current output 4…20 mA
Operating range 4…20 mA (2-wire)
Load
Accuracy LHR analog output ± 0.5 % FS BSL
Calibration accuracy 0-point 0.5 % FS
Calibration accuracy full scale 0.5 % FS
Temperature behaviour
Medium temperature -40…+150 °C
Ambient conditions
Ambient temperature -40…+85 °C
Storage temperature -40…+85 °C
Vibration resistance 20 g, 2…2000 Hz, with amplitude +/-15 mm acc. to
Shock resistance 100 g (11 ms) , acc. to IEC 68-2-27
Housing
Housing material Stainless steel, V2A (1.4305)
Pressure connection material Stainless steel A2 1.4305 (AISI 303)
Pressure transducer material 1.4305 (AISI 303)
Sealing material FPM
Process connection NPT ¼”-18 male thread
Wrench size pressure connection / coupling nut SW 21
Electrical connection Connector, M12 × 1
Max. tightening torque housing nut 20 Nm
ð 4 mA
ð 1 kò
IEC 60068-2-6
Edition • 2018-10-09T23:02:16+02:00
1 / 2 TURCK Inc.
Pressure Transmitter
with current output (2-wire)
PT510-7500PSIG-13-LI3-H1131
Reference conditions acc. to IEC 61298-1
Temperature 15…+25 °C
Atmospheric pressure 860…1060 hPa abs.
Humidity 45…75 % rel.
Auxiliary power 24 VDC
Edition • 2018-10-09T23:02:16+02:00
2 / 2 TURCK Inc.