![](/html/8e/8e7c/8e7c6c11a286befeeac4f97d2cc4b65155c924e2a5054c86bdc795ae458c4340/bg1.png)
Pressure Transmitter
With Current Output (2-wire)
PT300PSIG-2003-IX-H1143
Type designation PT300PSIG-2003-IX-H1143
Ident-No. 100002236
Pressure range
Relative pressure 0…20.68 bar rel.
0…300 psi
0…2.07 MPa
Admissible overpressure
Burst pressure
Response time < 2 ms, typ. 1 ms
Long-term stability 0.25% FS, according to IEC EN 60770-1
Power supply
Operating voltage 10…30 VDC
Current consumption
Short-circuit/reverse polarity protection yes / yes
Protection type and class IP67 / III
Insulation voltage 750 VDC
Outputs
Output 1 Analog output
ð 62.05 bar
ï 124.11 bar
ð 23 mA
■ ATEX category II 1/2 GD, Ex zone 0
■ Fully welded metal measuring cell
■ Pressure range 0…300 psi rel.
■ 10…30 VDC
■ Analog output 4…20 mA
■ Process connection 1/4"-18 NPT male
thread
■ Plug-in device, M12 × 1
Wiring Diagram
Functional principle
The pressure sensors of the PT…-2000 series
operate with a fully welded metal measuring
cell. Depending on the sensor variant, the processed signal is available as an analog output
signal of either (4…20 mA (2-wire) or 0…10 V,
0…5 V, 1…6 V (3-wire).
Analog output
Current output 4…20 mA
Operating range 4…20 mA (2-wire)
Load
Accuracy LHR analog output ± 0.3 % FS BSL
Temperature behaviour
Medium temperature -40…+135 °C
Temperature coefficient ± 0.2 % of full scale/10 K
Ambient conditions
Ambient temperature -30…+85 °C
Storage temperature -50…+100 °C
Vibration resistance 20 g, 15…2000 Hz, 15…25 Hz with amplitude +/-15
Shock resistance 100 g, 11 ms, half sinusoidal curve, all 6 directions,
Housing
Housing material Stainless-steel/Plastic, 1.4404 (316L)/ Polyary-
Pressure connection material Stainless steel 1.4404 (AISI 316L)
Pressure transducer material Stainless steel 1.4016 / AISI 430
Process connection NPT ¼”-18 male thread
Wrench size pressure connection / coupling nut 24
Electrical connection Connector, M12 × 1
Max. tightening torque housing nut 20 Nm
Edition • 2018-10-11T21:53:01+02:00
1 / 3 TURCK Inc.
ð (Supply voltage -10)/20 kò
mm acc. to IEC 68-2-6
free fall from 1 m onto concrete (6x) , acc. to IEC
68-2-27
lamide 50 % GF UL 94 V-0
![](/html/8e/8e7c/8e7c6c11a286befeeac4f97d2cc4b65155c924e2a5054c86bdc795ae458c4340/bg2.png)
Pressure Transmitter
With Current Output (2-wire)
PT300PSIG-2003-IX-H1143
Reference conditions acc. to IEC 61298-1
Temperature 15…+25 °C
Atmospheric pressure 860…1060 hPa abs.
Humidity 45…75 % rel.
Auxiliary power 24 VDC
Important note For intrinsically safe applications, the values
specified in the corresponding Ex certificates (ATEX, IECEX,
UL etc.) apply.
Ex approval acc. to conformity certificate SEV 10 ATEX 0145
Application area II 1/2 GD
Ignition protection category Gas Ex ia IIC; dust Ex ia IIIC
MTTF 1189 years acc. to SN 29500 (Ed. 99) 40 °C
Edition • 2018-10-11T21:53:01+02:00
2 / 3 TURCK Inc.