Pressure Transmitter
Ratiometric Output (3-wire)
PT3000PSIG-2005-U6-H1141
Type designation PT3000PSIG-2005-U6-H1141
Ident no. 100002923
Pressure range
Relative pressure 0…206.84 bar rel.
0…3000 psi
0…20.68 MPa
Admissible overpressure
Burst pressure
Response time < 2 ms, typ. 1 ms
Long-term stability 0.25% FS, according to IEC EN 60770-1
Power supply
Operating voltage 4.5…5.5 VDC
Current consumption
Short-circuit/reverse polarity protection yes / yes
Protection type and class IP67 / III
Insulation voltage 750 VDC
ð 620.53 bar
ï 1241.06 bar
ð 7 mA
■ Completely welded measuring cell
■ Compact and robust design
■ Excellent EMC properties
■ Pressure range 0…3000 psi rel.
Wiring Diagram
Functional principle
The pressure sensors of the PT …-2000 series operate with a fully welded metal measuring cell. Depending on the sensor variant, the
signal is converted into an analog output signal of either (4…20 mA (2-wire) or 0…10 V
(3-wire).
Outputs
Output 1 Analog output
Analog output
Voltage output 0.5…4.5V
Operating range ratiom. 10…90 % (3-wire)
Load
Accuracy LHR analog output ± 0.3 % FS BSL
Temperature behaviour
Medium temperature -40…+135 °C
Temperature coefficient ± 0.2 % of full scale/10 K
Ambient conditions
Ambient temperature -30…+85 °C
Storage temperature -50…+100 °C
Vibration resistance 20 g, 15…2000 Hz, 15…25 Hz with amplitude +/-15
Shock resistance 100 g, 11 ms, half sinusoidal curve, all 6 directions,
Housing
Housing material Stainless-steel/Plastic, Stainless steel V4A (1.4404)/
Pressure connection material Stainless steel V4A (1.4404)/AISI 316L
Pressure transducer material Stainless steel 1.4435 / AISI 316L
Process connection 7/16-20 UNF
Electrical connection Connectors, M12 × 1
Max. tightening torque housing nut 20 Nm
Edition • 2018-06-18T16:01:14+02:00
1 / 2 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com
ï 10 kò
mm acc. to IEC 68-2-6
free fall from 1 m onto concrete (6x) , according to
IEC 61508
Polyacrylamide 50% GF UL 94 V-0

Pressure Transmitter
Ratiometric Output (3-wire)
PT3000PSIG-2005-U6-H1141
Reference conditions acc. to IEC 61298-1
Temperature 15…+25 °C
Atmospheric pressure 860…1060 hPa abs.
Humidity 45…75 % rel.
Auxiliary power 24 VDC
MTTF 1564 years acc. to SN 29500 (Ed. 99) 40 °C
Edition • 2018-06-18T16:01:14+02:00
2 / 2 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com