![](/html/4b/4bbc/4bbc1a3c1ae334918fd7b46261bd5ee366edde1b6810092a95b926a4ed773f24/bg1.png)
Pressure Transmitter
With Current Output (2-Wire)
PT1VR-1001-I2-H1141
Type designation PT1VR-1001-I2-H1141
Ident-No. 6836030
Pressure range
Relative pressure -1…0 bar rel.
-14.5…0 psi
-0.1…0 MPa
Admissible overpressure
Burst pressure
Response time < 2 ms, typ. 1 ms
Long-term stability 0.25% FS, according to IEC EN 60770-1
ð 2 bar
ï 2 bar
■ Ceramic measuring cell
■ Compact and robust design
■ Excellent EMC properties
■ Pressure range -1…0 bar rel.
■ 7…33 VDC
■ Analog output 4…20 mA
■ Process connection G1/4" female
thread
■ Plug-in device, M12 × 1
Wiring Diagram
Power supply
Operating voltage 7…33 VDC
Current consumption
Short-circuit/reverse polarity protection yes / yes
Protection type and class IP67 / III
Insulation voltage 750 VDC
Outputs
Output 1 Analog output
Analog output
Current output 4…20 mA
Operating range 4…20 mA (2-wire)
Load
Accuracy LHR analog output ± 0.35 % FS BSL
Temperature behaviour
Medium temperature -40…+125 °C
Temperature coefficient ± 0.2 % of full scale/10 K
Ambient conditions
Ambient temperature -30…+85 °C
Storage temperature -50…+100 °C
Vibration resistance 20 g, 15…2000 Hz, 15…25 Hz with amplitude +/-15
Shock resistance 100 g, 11 ms, half sinusoidal curve, all 6 directions,
ð 23 mA
ð (Supply voltage -7)/20 kò
mm acc. to IEC 68-2-6
free fall from 1 m onto concrete (6x) , acc. to IEC
68-2-27
Functional principle
The pressure sensors of the PT …-1000 series operate with a ceramic measuring cell.
Depending on the sensor variant, the processed signal is available as an analog output
signal of either (4…20 mA (2-wire) or 0…10 V,
0…5 V, 1…6 V (3-wire).
Edition • 2018-10-12T15:41:52+02:00
1 / 2 TURCK Inc.
![](/html/4b/4bbc/4bbc1a3c1ae334918fd7b46261bd5ee366edde1b6810092a95b926a4ed773f24/bg2.png)
Pressure Transmitter
With Current Output (2-Wire)
PT1VR-1001-I2-H1141
Housing
Housing material Stainless-steel/Plastic, 1.4404 (316L)/ Polyary-
lamide 50 % GF UL 94 V-0
Pressure connection material Stainless steel 1.4404 (AISI 316L)
Pressure transducer material Ceramic Al2O
Sealing material FPM spez.
Process connection G¼” female thread
Wrench size pressure connection / coupling nut 24
Electrical connection Connector, M12 × 1
Max. tightening torque housing nut 20 Nm
Reference conditions acc. to IEC 61298-1
Temperature 15…+25 °C
Atmospheric pressure 860…1060 hPa abs.
Humidity 45…75 % rel.
Auxiliary power 24 VDC
MTTF 1189 years acc. to SN 29500 (Ed. 99) 40 °C
3
Edition • 2018-10-12T15:41:52+02:00