Pressure Transmitter
With Current Output (3-Wire)
PT15PSIV-1013-IX-H1143
Type designation PT15PSIV-1013-IX-H1143
Ident-No. 100002705
Pressure range
-15…15 psi
Burst pressure
Response time < 2 ms, typ. 1 ms
Long-term stability 0.25% FS, according to IEC EN 60770-1
ï 7.5 bar
■ ATEX category II 1/2 GD, Ex zone 0
■ Ceramic measuring cell
■ Compact and robust design
■ Excellent EMC properties
■ ATEX Ex II 1/2 GD
■ FPM sealing material
■ 10…30 VDC
■ Analog output 4…20 mA
■ Process connection G1/8" male thread
■ Plug-in device, M12 × 1
Wiring Diagram
Power supply
Operating voltage 10…30 VDC
Current consumption
Short-circuit/reverse polarity protection yes / yes
Protection type and class IP67 / III
Insulation voltage 750 VDC
Outputs
Output 1 Analog output
Analog output
Current output 4…20 mA
Operating range 4…20 mA (2-wire)
Load
Temperature behaviour
Medium temperature -30…+120 °C
Temperature coefficient ± 0.2 % of full scale/10 K
Ambient conditions
Ambient temperature -35…+85 °C
Storage temperature -50…+100 °C
Vibration resistance 20 g, 15…2000 Hz, 15…25 Hz with amplitude +/-15
Shock resistance 100 g, 11 ms, half sinusoidal curve, all 6 directions,
Housing
Housing material Stainless-steel/Plastic, 1.4404 (316L)/ Polyary-
Pressure connection material Stainless steel 1.4404 (AISI 316L)
Pressure transducer material Ceramic Al2O
Sealing material FPM spez.
Process connection G⅛” male thread
Wrench size pressure connection / coupling nut 24
Electrical connection Connector, M12 × 1
Max. tightening torque housing nut 20 Nm
ð 23 mA
ð (Supply voltage -10)/20 kò
mm acc. to IEC 68-2-6
free fall from 1 m onto concrete (6x) , acc. to IEC
68-2-27
lamide 50 % GF UL 94 V-0
3
Functional principle
The pressure sensors of the PT …-1000 series operate with a ceramic measuring cell.
Depending on the sensor variant, the processed signal is available as an analog output
signal of either (4…20 mA (2-wire) or 0…10 V,
0…5 V, 1…6 V (3-wire).
Edition • 2018-09-24T16:50:47+02:00
1 / 3 TURCK Inc.
Pressure Transmitter
With Current Output (3-Wire)
PT15PSIV-1013-IX-H1143
Reference conditions acc. to IEC 61298-1
Temperature 15…+25 °C
Atmospheric pressure 860…1060 hPa abs.
Humidity 45…75 % rel.
Auxiliary power 24 VDC
Important note For intrinsically safe applications, the values
specified in the corresponding Ex certificates (ATEX, IECEX,
UL etc.) apply.
Ex approval acc. to conformity certificate SEV 10 ATEX 0145
Application area II 1/2 GD
Ignition protection category Gas Ex ia IIC; dust Ex ia IIIC
MTTF 1189 years acc. to SN 29500 (Ed. 99) 40 °C
Edition • 2018-09-24T16:50:47+02:00
2 / 3 TURCK Inc.