Pressure Transmitter
With Voltage Output (3-wire)
PT10R-2001-U1-H1141
Type designation PT10R-2001-U1-H1141
Ident-No. 6836300
Pressure range
Relative pressure 0…10 bar rel.
0…145 psi
0…1 MPa
Admissible overpressure
Burst pressure
Response time < 2 ms, typ. 1 ms
Long-term stability 0.25% FS, according to IEC EN 60770-1
Power supply
Operating voltage 12…33 VDC
Current consumption
Short-circuit/reverse polarity protection yes / yes
Protection type and class IP67 / III
Insulation voltage 750 VDC
ð 30 bar
ï 60 bar
ð 7 mA
■ Fully welded metal measuring cell
■ Pressure range 0…10 bar rel.
■ 12…33 VDC
■ Analog output 0…10 V
■ Process connection G1/4" female
thread
■ Plug-in device, M12 × 1
Wiring Diagram
Functional principle
The pressure sensors of the PT…-2000 series
operate with a fully welded metal measuring
cell. Depending on the sensor variant, the processed signal is available as an analog output
signal of either (4…20 mA (2-wire) or 0…10 V,
0…5 V, 1…6 V (3-wire).
Outputs
Output 1 Analog output
Analog output
Voltage output 0…10V
Operating range 0…10 V (3-wire)
Load
Accuracy LHR analog output ± 0.3 % FS BSL
Temperature behaviour
Medium temperature -40…+135 °C
Temperature coefficient ± 0.2 % of full scale/10 K
Ambient conditions
Ambient temperature -30…+85 °C
Storage temperature -50…+100 °C
Vibration resistance 20 g, 15…2000 Hz, 15…25 Hz with amplitude +/-15
Shock resistance 100 g, 11 ms, half sinusoidal curve, all 6 directions,
Housing
Housing material Stainless-steel/Plastic, 1.4404 (316L)/ Polyary-
Pressure connection material Stainless steel 1.4404 (AISI 316L)
Pressure transducer material Stainless steel 1.4016 / AISI 430
Process connection G¼” female thread
Wrench size pressure connection / coupling nut 24
Electrical connection Connector, M12 × 1
Max. tightening torque housing nut 20 Nm
Edition • 2018-10-12T17:35:15+02:00
1 / 2 TURCK Inc.
ð 100 nF/>10 kò
mm acc. to IEC 68-2-6
free fall from 1 m onto concrete (6x) , acc. to IEC
68-2-27
lamide 50 % GF UL 94 V-0
Pressure Transmitter
With Voltage Output (3-wire)
PT10R-2001-U1-H1141
Reference conditions acc. to IEC 61298-1
Temperature 15…+25 °C
Atmospheric pressure 860…1060 hPa abs.
Humidity 45…75 % rel.
Auxiliary power 24 VDC
MTTF 1238 years acc. to SN 29500 (Ed. 99) 40 °C
Edition • 2018-10-12T17:35:15+02:00
2 / 2 TURCK Inc.