![](/html/ff/ff39/ff39abfa2bd907bd3db113656a9bab18784409a804fd54c3e4d69b2330d5814b/bg1.png)
Pressure Transmitter
With Current Output (2-wire)
PT100R-2005-I2-H1143/X
Type designation PT100R-2005-I2-H1143/X
Ident-No. 100001186
Pressure range
Relative pressure 0…100 bar rel.
0…1450 psi
0…10 MPa
Admissible overpressure
Burst pressure
Response time < 2 ms, typ. 1 ms
Long-term stability 0.25% FS, according to IEC EN 60770-1
Power supply
Operating voltage 7…33 VDC
Current consumption
Short-circuit/reverse polarity protection yes / yes
Protection type and class IP67 / III
Insulation voltage 750 VDC
Outputs
Output 1 Analog output
ð 300 bar
ï 600 bar
ð 23 mA
■ Fully welded metal measuring cell
■ Pressure range 0…100 bar rel.
■ Pressure tip orifice
■ 7…33 VDC
■ Analog output 4…20 mA
■ Process connection 7/16" UNF (SAE)
male thread
■ Plug-in device, M12 × 1
Wiring Diagram
Functional principle
The pressure sensors of the PT…-2000 series
operate with a fully welded metal measuring
cell. Depending on the sensor variant, the processed signal is available as an analog output
signal of either (4…20 mA (2-wire) or 0…10 V,
0…5 V, 1…6 V (3-wire).
Analog output
Current output 4…20 mA
Operating range 4…20 mA (2-wire)
Load
Accuracy LHR analog output ± 0.3 % FS BSL
Temperature behaviour
Medium temperature -40…+135 °C
Temperature coefficient ± 0.2 % of full scale/10 K
Ambient conditions
Ambient temperature -30…+85 °C
Storage temperature -50…+100 °C
Vibration resistance 20 g, 15…2000 Hz, 15…25 Hz with amplitude +/-15
Shock resistance 100 g, 11 ms, half sinusoidal curve, all 6 directions,
Housing
Housing material Stainless-steel/Plastic, 1.4404 (316L)/ Polyary-
Pressure connection material Stainless steel 1.4404 (AISI 316L)
Pressure transducer material Stainless steel 1.4435/AISI 316L
Process connection 7/16”-20 UNF
Wrench size pressure connection / coupling nut 24
Electrical connection Connector, M12 × 1
Max. tightening torque housing nut 20 Nm
Edition • 2018-10-10T21:49:17+02:00
1 / 2 TURCK Inc.
ð (Supply voltage -7)/20 kò
mm acc. to IEC 68-2-6
free fall from 1 m onto concrete (6x) , acc. to IEC
68-2-27
lamide 50 % GF UL 94 V-0
![](/html/ff/ff39/ff39abfa2bd907bd3db113656a9bab18784409a804fd54c3e4d69b2330d5814b/bg2.png)
Pressure Transmitter
With Current Output (2-wire)
PT100R-2005-I2-H1143/X
Reference conditions acc. to IEC 61298-1
Temperature 15…+25 °C
Atmospheric pressure 860…1060 hPa abs.
Humidity 45…75 % rel.
Auxiliary power 24 VDC
MTTF 1189 years acc. to SN 29500 (Ed. 99) 40 °C
Edition • 2018-10-10T21:49:17+02:00
2 / 2 TURCK Inc.