Operating voltage18…30 VDC
Current consumption
Voltage drop at I
Protective measureSELV; PELV according to EN 50178
Short-circuit/reverse polarity protectionyes/ yes
Protection type and classIP67/IP69K/ III
Outputs
Output 1Switching output or IO-Link mode
Output 2analog output
Switching output
Output functionNO/NC contact, PNP/NPN
Accuracy switching output± 0.5 % v. E. BSL
Rated operational current0.2 A
Switching frequency
Switching point distance
Switch point:(min + 0.005 x range) up to 100% f.s.
Release point(s)min up to (SP - 0.005 x range)
Switching cycles
e
ð 80 bar
ï 80 bar
ð 50 mA
ð 2 V
ð 180 Hz
ï 0.5 %
ï 100 mil.
Functional principle
The pressure sensors of the PS series operate with piezo-resistive ceramic measuring
cells. The ceramic diaphragm is unbalanced
in proportion to the pressure applied. Depending on the sensor type, the voltage produced
is made available either as switching or analog output signal. Non-rotatable and rotatable
sensors, numerous thread types, front-flush or
dead-zone free diaphragms and an accuracy
of 0.5% of full scale guarantee highest flexibility and safe process interfacing.
Analogue output
Voltage output0…10V
Operating range0…10 V, 0…5 V (3-wire)
Load
Accuracy LHR analog output± 0.5 % of final value BSL
IO-Link
IO-Link SpecificationSpecified acc. to version 1.0
ProgrammingFDT / DTM
Transmission physicscorresponds to 3-wire physics (PHY2)
Transmission rateCOM 2 / 38.4 kbps
Process data width16 bit
Measured value information14 bit
Switchpoint information2 bit
Frame type2.2
Genauigkeit± 0.5 % of final value BSL
Edition • 2017-02-10T17:29:36+01:00
1 / 4TURCK Inc.
ï 2 kò
Pressure sensor
with voltage output and PNP/NPN transistor switching output
PS016V-304-LUUPN8X-H1141
Temperature behaviour
Medium temperature-40…+85 °C
Temperature coefficient zero point Tk0± 0.15 % of full scale/10 K
Temperature coefficient span T
Ambient conditions
Ambient temperature-40…+80 °C
Storage temperature-40…+80°C
Vibration resistance20 g (9…2000 Hz), according to IEC 68-2-6
Shock resistance50 g (11 ms) , according to IEC 61508
EMCEN 61000-4-2 ESD:4 kV CD / 8 kV AD