Pressure Instrumentation
High Accuracy Programmable Pressure Sensor Part Number Key
PS 010V - 5 03 - LI2UPN 8 X - H1141
Pressure Sensor
Nominal Pressure Range
01VR = -1 to 0 bar gauge (-14.5 to 0 psi)
001R = 0 to 1 bar gauge (0 to 14.5 psi)
001V = -1 to 1 bar gauge (-14.5 to 14.5 psi)
003V = -1 to 2.5 bar gauge (-14.5 to 36 psi)
010V = -1 to 10 bar gauge (-14.5 to 145 psi)
016V = -1 to 16 bar gauge (-14.5 to 232 psi)
025V = -1 to 25 bar gauge (-14.5 to 362 psi)
040V = -1 to 40 bar gauge (-14.5 to 580 psi)
100R = 0 to 100 bar gauge (0 to 1450 psi)
250R = 0 to 250 bar gauge (0 to 3625 psi)
400R = 0 to 400 bar gauge (0 to 5800 psi)
600R = 0 to 600 bar gauge (0 to 8700 psi)
001A = 0 to 1 bar absolute (0 to 14.5 psi)
003A = 0 to 2.5 bar absolute (0 to 36 psi)
010A = 0 to 10 bar absolute (0 to 145 psi)
016A = 0 to 16 bar absolute (0 to 232 psi)
025A = 0 to 25 bar absolute (0 to 362 psi)
Electrical Output Output 1 Output 2
2UPN switching output switching output
LUUPN switching output voltage output
LI2UPN switching output current/switching output
Pressure Connection
01 = G1/4" female thread
03 = 1/4"-18 NPT male thread
04 = G1/4" male thread
05 = 7/16"-20 UNF male thread
Housing
5 = Rotatable
3 = IP69k
Connection
H1141 = 4-pin male, M12x1 (eurofast®)
with LED
Operating Voltage
8 = 15(18)...30 VDC
PRESSURE
TURCK Inc. Minneapolis, MN 55441 B1052 B4

Pressure Instrumentation
PS500 Programmable Pressure Sensor Specifications
Electrical
Operating Voltage 15-30 VDC
Current Consumption ≤50 mA
Power-On Effect Per IEC 947-5-2
Reverse Polarity Protection Yes
Transient Protection EN 60947-5-2
Short-Circuit Protection Yes
EMC Information
EN 61000-4-2 ESD: 4 KD CK/ 8 KV AD
EN 61000-4-3 HF irradiated: 15 V/m
EN 61000-4-4 Burst: 2 KV
EN 61000-4-5 Surge: 500 V, 12 Ω
EN 61000-4-6 HF conducted: 10 V
Environmental
Ambient Temperature -40°to +80°C (-40°to +176°F)
Medium Temperature -25°to +85°C (-40°to +185°F)
Enclosure Rating Meets NEMA 4, 6, 12, 13 and IP67
Shock 50 g per IEC 68-2-27
Vibration 20 g (10-200 Hz) per IEC 68-2-6
Burst Protection patented media stop
Materials
Housing Stainless Steel 303
Wetted Parts Stainless Steel 303, Viton Al
Operational
Output Programmable Current:
. 0-20 mA, 4-20 mA,
. 20-0 mA, 20-4 mA and
. 1 PNP/NPN N.O./N.C. Or
. 2 PNP/NPN N.O./N.C.
Switching Frequency ≤180 Hz
Switching Current ≤200 mA
2O3
Ceramic
Operational continued
Accuracy
Set Point Accuracy ±0.5% Of Full Scale
Repeatability ≤0.5% of measuring range
Zero Shift/Span Shift ≤0.15% of measuring range/°C
Set Points
Set Point Range 1% - 100% Range
Reset Point Range .5% - 99.5% Range
Minimum Hysteresis ±0.5% Of Full Scale
Switching Delay Switch-on and switch-off
Measuring Value 4-digit 7-segment display
Programming
Status Display
Display Reaction Time Slow 600 ms update
. delay adjustable from 0 to 50
. seconds in steps of 0.1 second
LED Function/Display
Programming
LEDs indicate output status and
. selected measuring units
. Normal 200 ms update
. Fast 50 ms update
PRESSURE
Wiring Diagram
Mating Cordset:
RK 4.4T-*
Wiring Diagram
Drawings
1
TURCK Inc. Minneapolis, MN 55441 B1052 B10
2