We reserve the right to make technical alterations without prior notice.
Rear Mount
PCB Mount
M30F42
Bulkhead Feed-thruF47
PCB PinsF45
7/8” minifast® Connectivity Products
2 and 3-Wire Receptacles, Front Mount, 1/2-14 NPSM Threads
y
NEMA 1, 3, 4, 6P
y IEC IP67 Protection
Housing StyleFemale Part NumberMale Part NumberFeaturesPinout
RKF ..
Typical panel cutout 22.5 mm
RSF ..
RKF 20-*MRSF 20-*M
RKF 26-*MRSF 26-*M
RKF 28-*MRSF 28-*M
RKF 30-*MRSF 30-*M
RKF 31-*MRSF 31-*M
RKF 311-*MRSF 311-*M
RKF 35-*MRSF 35-*M
2x18 AWG 105 °C, 600 V,
9 A, standard duty
2x16 AWG Leads, 105 °C,
600 V, 10 A, heavy duty
2x18 AWG, 105 °C, 600 V,
9 A, heavy duty
3x18 AWG, 105 °C, 600 V,
9 A, standard duty
3x18 AWG, 105 °C, 600 V,
9 A, standard duty
3x18 AWG, 105 °C, 600 V,
9 A, automotive color
code
3x16 AWG, 105 °C, 600 V,
10 A, automotive color
code
1. BN
2. BU
1. WH
2. BK
1. WH
2. BK
1. GY/YE
2. BN
3. BU
1. BK
2. BN
3. BU
1. GN
2. RD/BK
3. RD/WH
Female/Male
Receptacles
Female
Male
We reserve the right to make technical alterations without prior notice.
**
Typical panel cutout 22.5 mm
Standard lead length is 0.3 meters. Consult factory for other lengths.
Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing.
For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
B2007 F25
RKF 36-*MRSF 36-*M
RKF 38-*MRSF 38-*M
3x16 AWG, 105 °C, 600 V,
10 A, heavy duty
3x18 AWG, 105 °C, 600 V,
9 A, heavy duty
1. GN
2. BK
3. WH
1. GN
2. BK
3. WH
7/8” minifast® Connectivity Products
4-Wire Receptacles, Front Mount, 1/2-14 NPSM Threads
y NEMA 1, 3, 4, 6Py IEC IP67 Protection
Housing StyleFemale Part NumberMale Part NumberFeaturesPinout
Female
RKF ..
Typical panel cutout 22.5 mm
RSF ..
RKF 40-*MRSF 40-*M
RKF 46-*MRSF 46-*M
4x18 AWG 105 °C, 600 V,
9 A, standard duty
4x16 AWG, 105 °C, 600 V,
10 A, heavy duty
1. BN
2. WH
3. BU
4. BK
1. BK
2. WH
3. RD
4. GN
Male
We reserve the right to make technical alterations without prior notice.
Female
Male
Female
Typical panel cutout 22.5 mm
RKF 48-*MRSF 48-*M
Standard lead length is 0.3 meters. Consult factory for other lengths.
**
Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing.
For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
5-Wire Receptacles, Front Mount, 1/2-14 NPSM Threads
y
NEMA 1, 3, 4, 6P
y IEC IP67 Protection
Housing StyleFemale Part NumberMale Part NumberFeaturesPinout
RKF 50-*MRSF 50-*M
RKF ..
5x18 AWG, 105 °C, 600 V,
9 A, standard duty
1. BK
2. BU
3. GN/YE
4. BN
5. WH
Female
5x18 AWG, 105 °C, 600 V,
Typical panel cutout 22.5 mm
RSF ..
Typical panel cutout 22.5 mm
Standard lead length is 0.3 meters. Consult factory for other lengths.
We reserve the right to make technical alterations without prior notice.
**
Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing.
For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
RKF 511-*MRSF 511-*M
RKF 55-*MRSF 55-*M
RKF 56-*MRSF 56-*M
RKF 58-*MRSF 58-*M
9 A, automotive color
code
5x16 AWG, 105 °C, 600 V,
10 A, automotive color
code
5x16 AWG, 105 °C, 600 V,
10 A, heavy duty
5x18 AWG, 105 °C, 300 V,
9 A, heavy duty
1. RD/WH
2. RD/BU
3. GN
4. RD/OG
5. RD/BK
1. RD/WH
2. RD/BU
3. GN
4. RD/OG
5. RD/BK
1. WH
2. RD
3. GN
4. OG
5. BK
Receptacles
Male
B2007 F27
7/8” minifast® Connectivity Products
6-Wire Receptacles, Front Mount, 1/2-14 NPSM Threads
y NEMA 1, 3, 4, 6Py IEC IP67 Protection
Housing StyleFemale Part NumberMale Part NumberFeaturesPinout
RKF ..
RKF 61-*MRSF 61-*M
Typical panel cutout 22.5 mm
RKF 66-*MRSF 66-*M
RSF ..
RKF 68-*MRSF 68-*M
Typical panel cutout 22.5 mm
Standard lead length is 0.3 meters. Consult factory for other lengths.
**
Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing.
For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
6x18 AWG, 105 °C, 600 V,
8 A, standard threads
6x16 AWG, 105 °C, 600 V,
8 A, heavy duty
6x18 AWG, 105 °C, 600 V,
8 A, heavy duty
1. GN
2. WH
3. BU
4. Gy
5. YE
6. BN
1. WH
2. RD
3. GN
4. OG
5. BK
6. BU
Female
Male
We reserve the right to make technical alterations without prior notice.
2 and 3-Wire Receptacles, Front Mount, 1/2-14 NPT Threads
y
NEMA 1, 3, 4, 6P
y IEC IP67 Protection
Housing StyleFemale Part NumberMale Part NumberFeaturesPinout
RKF ..NPT
Typical panel cutout 22.5 mm
RSF ..NPT
RKF 20-*M/NPTRSF 20-*M/NPT
RKF 26-*M/NPTRSF 26-*M/NPT
RKF 28-*M/NPTRSF 28-*M/NPT
RKF 30-*M/NPTRSF 30-*M/NPT
RKF 31-*M/NPTRSF 31-*M/NPT
RKF 311-*M/NPTRSF 311-*M/NPT
RKF 35-*M/NPTRSF 35-*M/NPT
2x18 AWG, 105 °C, 9 A,
standard duty
2x16 AWG Leads, 105 °C,
10 A, heavy duty
2x18 AWG, 105 °C, 600 V,
9 A, heavy duty
3x18 AWG, 105 °C, 9 A,
standard duty
3x18 AWG, 105 °C, 9 A,
standard duty
3x18 AWG, 105 °C, 9 A,
automotive color code
3x16 AWG, 105 °C, 10 A,
automotive color code
1. BN
2. BU
1. WH
2. BK
1. WH
2. BK
1. GY/YE
2. BN
3. BU
1. BK
2. BN
3. BU
1. GN
2. RD/BK
3. RD/WH
Female/Male
Receptacles
Female
Male
We reserve the right to make technical alterations without prior notice.
**
Typical panel cutout 22.5 mm
Standard lead length is 0.3 meters. Consult factory for other lengths.
Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing.
For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
B2007 F29
RKF 36-*M/NPTRSF 36-*M/NPT
RKF 38-*M/NPTRSF 38-*M/NPT
3x16 AWG, 105 °C, 10 A,
heavy duty
3x18 AWG, 105 °C, 600 V,
9 A, heavy duty
1. GN
2. BK
3. WH
1. GN
2. BK
3. WH
7/8” minifast® Connectivity Products
4-Wire Receptacles, Front Mount, 1/2-14 NPT Threads
y NEMA 1, 3, 4, 6Py IEC IP67 Protectiony 600 V
Housing StyleFemale Part NumberMale Part NumberFeaturesPinout
RKF ..NPT
Typical panel cutout 22.5 mm
RKF 40-*M/NPTRSF 40-*M/NPT
4x18 AWG, 105 °C, 9 A,
standard duty
1. BN
2. WH
3. BU
4. BK
Female
Male
Female
We reserve the right to make technical alterations without prior notice.
RKF 46-*M/NPTRSF 46-*M/NPT
RSF ..NPT
Typical panel cutout 22.5 mm
Standard lead length is 0.3 meters. Consult factory for other lengths.
**
Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing.
For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
5 and 6-Wire Receptacles, Front Mount, 1/2-14 NPT Threads
y
NEMA 1, 3, 4, 6P
y IEC IP67 Protectiony 600 V
Housing StyleFemale Part NumberMale Part NumberFeaturesPinout
RKF 50-*M/NPTRSF 50-*M/NPT
5x18 AWG, 105 °C, 9 A,
standard duty
1. BK
2. BU
3. GN/YE
4. BN
5. WH
Female
RKF ..NPT
Typical panel cutout 22.5 mm
RSF ..NPT
We reserve the right to make technical alterations without prior notice.
Typical panel cutout 22.5 mm
RKF 511-*M/NPTRSF 511-*M/NPT
RKF 55-*M/NPTRSF 55-*M/NPT
RKF 56-*M/NPTRSF 56-*M/NPT
RKF 58-*M/NPTRSF 58-*M/NPT
RKF 61-*M/NPTRSF 61-*M/NPT
RKF 66-*M/NPTRSF 66-*M/NPT
RKF 68-*M/NPTRSF 68-*M/NPT
5x18 AWG, 105 °C, 9 A,
automotive color code
5x16 AWG, 105 °C, 10 A,
automotive color code
5x16 AWG, 105 °C, 10 A,
heavy duty
5x18 AWG, 105 °C, 300 V,
9 A, heavy duty
6x18 AWG, 105 °C, 8 A,
standard duty
6x16 AWG, 105 °C, 8 A,
heavy duty
6x18 AWG, 105 °C, 600 V,
8 A, heavy duty
1. RD/WH
2. RD/BU
3. GN
4. RD/OG
5. RD/BK
1. WH
2. RD
3. GN
4. OG
5. BK
1. GN
2. WH
3. BU
4. GY
5. YE
6. BN
1. WH
2. RD
3. GN
4. OG
5. BK
6. BU
Receptacles
Male
Female
Male
Standard lead length is 0.3 meters. Consult factory for other lengths.
**
Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing.
For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
B2007 F31
Loading...