Turck minifast Catalog Page

minifast® Connectivity Products
Mounting Style Image Panel Thread Types Page
1/2-14 NPSM F25
1/2-14 NPT F29, F36, F38, F40
Front Mount
M20 F32-F35, F41
3/4-14 NPT F37, F39, F40
PG16 F41
We reserve the right to make technical alterations without prior notice.
Rear Mount
PCB Mount
M30 F42
Bulkhead Feed-thru F47
PCB Pins F45
7/8” minifast® Connectivity Products
2 and 3-Wire Receptacles, Front Mount, 1/2-14 NPSM Threads
y
NEMA 1, 3, 4, 6P
y IEC IP67 Protection
Housing Style Female Part Number Male Part Number Features Pinout
RKF ..
Typical panel cutout 22.5 mm
RSF ..
RKF 20-*M RSF 20-*M
RKF 26-*M RSF 26-*M
RKF 28-*M RSF 28-*M
RKF 30-*M RSF 30-*M
RKF 31-*M RSF 31-*M
RKF 311-*M RSF 311-*M
RKF 35-*M RSF 35-*M
2x18 AWG 105 °C, 600 V, 9 A, standard duty
2x16 AWG Leads, 105 °C, 600 V, 10 A, heavy duty
2x18 AWG, 105 °C, 600 V, 9 A, heavy duty
3x18 AWG, 105 °C, 600 V, 9 A, standard duty
3x18 AWG, 105 °C, 600 V, 9 A, standard duty
3x18 AWG, 105 °C, 600 V, 9 A, automotive color code
3x16 AWG, 105 °C, 600 V, 10 A, automotive color code
1. BN
2. BU
1. WH
2. BK
1. WH
2. BK
1. GY/YE
2. BN
3. BU
1. BK
2. BN
3. BU
1. GN
2. RD/BK
3. RD/WH
Female/Male
Receptacles
Female
Male
We reserve the right to make technical alterations without prior notice.
**
Typical panel cutout 22.5 mm
Standard lead length is 0.3 meters. Consult factory for other lengths. Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing. For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
B2007 F25
RKF 36-*M RSF 36-*M
RKF 38-*M RSF 38-*M
3x16 AWG, 105 °C, 600 V, 10 A, heavy duty
3x18 AWG, 105 °C, 600 V, 9 A, heavy duty
1. GN
2. BK
3. WH
1. GN
2. BK
3. WH
7/8” minifast® Connectivity Products
4-Wire Receptacles, Front Mount, 1/2-14 NPSM Threads
y NEMA 1, 3, 4, 6P y IEC IP67 Protection
Housing Style Female Part Number Male Part Number Features Pinout
Female
RKF ..
Typical panel cutout 22.5 mm
RSF ..
RKF 40-*M RSF 40-*M
RKF 46-*M RSF 46-*M
4x18 AWG 105 °C, 600 V, 9 A, standard duty
4x16 AWG, 105 °C, 600 V, 10 A, heavy duty
1. BN
2. WH
3. BU
4. BK
1. BK
2. WH
3. RD
4. GN
Male
We reserve the right to make technical alterations without prior notice.
Female
Male
Female
Typical panel cutout 22.5 mm
RKF 48-*M RSF 48-*M
Standard lead length is 0.3 meters. Consult factory for other lengths.
**
Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing. For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
3x18 AWG, 105 °C, 600 V, 9 A, standard duty
1. BN
2. N/C
3. BU
4. N/C
Male
F26 B2007 www.turck.com 1-800-544-7769 Fax: (763) 553-0708 Turck Minneapolis, MN 55441 B2007 F27
7/8” minifast® Connectivity Products
5-Wire Receptacles, Front Mount, 1/2-14 NPSM Threads
y
NEMA 1, 3, 4, 6P
y IEC IP67 Protection
Housing Style Female Part Number Male Part Number Features Pinout
RKF 50-*M RSF 50-*M
RKF ..
5x18 AWG, 105 °C, 600 V, 9 A, standard duty
1. BK
2. BU
3. GN/YE
4. BN
5. WH
Female
5x18 AWG, 105 °C, 600 V,
Typical panel cutout 22.5 mm
RSF ..
Typical panel cutout 22.5 mm
Standard lead length is 0.3 meters. Consult factory for other lengths.
We reserve the right to make technical alterations without prior notice.
**
Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing. For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
RKF 511-*M RSF 511-*M
RKF 55-*M RSF 55-*M
RKF 56-*M RSF 56-*M
RKF 58-*M RSF 58-*M
9 A, automotive color code
5x16 AWG, 105 °C, 600 V, 10 A, automotive color code
5x16 AWG, 105 °C, 600 V, 10 A, heavy duty
5x18 AWG, 105 °C, 300 V, 9 A, heavy duty
1. RD/WH
2. RD/BU
3. GN
4. RD/OG
5. RD/BK
1. RD/WH
2. RD/BU
3. GN
4. RD/OG
5. RD/BK
1. WH
2. RD
3. GN
4. OG
5. BK
Receptacles
Male
B2007 F27
7/8” minifast® Connectivity Products
6-Wire Receptacles, Front Mount, 1/2-14 NPSM Threads
y NEMA 1, 3, 4, 6P y IEC IP67 Protection
Housing Style Female Part Number Male Part Number Features Pinout
RKF ..
RKF 61-*M RSF 61-*M
Typical panel cutout 22.5 mm
RKF 66-*M RSF 66-*M
RSF ..
RKF 68-*M RSF 68-*M
Typical panel cutout 22.5 mm
Standard lead length is 0.3 meters. Consult factory for other lengths.
**
Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing. For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
6x18 AWG, 105 °C, 600 V, 8 A, standard threads
6x16 AWG, 105 °C, 600 V, 8 A, heavy duty
6x18 AWG, 105 °C, 600 V, 8 A, heavy duty
1. GN
2. WH
3. BU
4. Gy
5. YE
6. BN
1. WH
2. RD
3. GN
4. OG
5. BK
6. BU
Female
Male
We reserve the right to make technical alterations without prior notice.
F28 B2007 www.turck.com 1-800-544-7769 Fax: (763) 553-0708 Turck Minneapolis, MN 55441 B2007 F29
7/8” minifast® Connectivity Products
2 and 3-Wire Receptacles, Front Mount, 1/2-14 NPT Threads
y
NEMA 1, 3, 4, 6P
y IEC IP67 Protection
Housing Style Female Part Number Male Part Number Features Pinout
RKF ..NPT
Typical panel cutout 22.5 mm
RSF ..NPT
RKF 20-*M/NPT RSF 20-*M/NPT
RKF 26-*M/NPT RSF 26-*M/NPT
RKF 28-*M/NPT RSF 28-*M/NPT
RKF 30-*M/NPT RSF 30-*M/NPT
RKF 31-*M/NPT RSF 31-*M/NPT
RKF 311-*M/NPT RSF 311-*M/NPT
RKF 35-*M/NPT RSF 35-*M/NPT
2x18 AWG, 105 °C, 9 A, standard duty
2x16 AWG Leads, 105 °C, 10 A, heavy duty
2x18 AWG, 105 °C, 600 V, 9 A, heavy duty
3x18 AWG, 105 °C, 9 A, standard duty
3x18 AWG, 105 °C, 9 A, standard duty
3x18 AWG, 105 °C, 9 A, automotive color code
3x16 AWG, 105 °C, 10 A, automotive color code
1. BN
2. BU
1. WH
2. BK
1. WH
2. BK
1. GY/YE
2. BN
3. BU
1. BK
2. BN
3. BU
1. GN
2. RD/BK
3. RD/WH
Female/Male
Receptacles
Female
Male
We reserve the right to make technical alterations without prior notice.
**
Typical panel cutout 22.5 mm
Standard lead length is 0.3 meters. Consult factory for other lengths. Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing. For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
B2007 F29
RKF 36-*M/NPT RSF 36-*M/NPT
RKF 38-*M/NPT RSF 38-*M/NPT
3x16 AWG, 105 °C, 10 A, heavy duty
3x18 AWG, 105 °C, 600 V, 9 A, heavy duty
1. GN
2. BK
3. WH
1. GN
2. BK
3. WH
7/8” minifast® Connectivity Products
4-Wire Receptacles, Front Mount, 1/2-14 NPT Threads
y NEMA 1, 3, 4, 6P y IEC IP67 Protection y 600 V
Housing Style Female Part Number Male Part Number Features Pinout
RKF ..NPT
Typical panel cutout 22.5 mm
RKF 40-*M/NPT RSF 40-*M/NPT
4x18 AWG, 105 °C, 9 A, standard duty
1. BN
2. WH
3. BU
4. BK
Female
Male
Female
We reserve the right to make technical alterations without prior notice.
RKF 46-*M/NPT RSF 46-*M/NPT
RSF ..NPT
Typical panel cutout 22.5 mm
Standard lead length is 0.3 meters. Consult factory for other lengths.
**
Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing. For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
RKF 48A-*M/NPT RSF 48A-*M/NPT
4x16 AWG, 105 °C, 10 A, heavy duty
1. BK
2. WH
3. RD
4. GN
4x18 AWG, 105 °C, 9 A, heavy duty
Male
Female
Male
F30 B2007 www.turck.com 1-800-544-7769 Fax: (763) 553-0708 Turck Minneapolis, MN 55441 B2007 F31
7/8” minifast® Connectivity Products
5 and 6-Wire Receptacles, Front Mount, 1/2-14 NPT Threads
y
NEMA 1, 3, 4, 6P
y IEC IP67 Protection y 600 V
Housing Style Female Part Number Male Part Number Features Pinout
RKF 50-*M/NPT RSF 50-*M/NPT
5x18 AWG, 105 °C, 9 A, standard duty
1. BK
2. BU
3. GN/YE
4. BN
5. WH
Female
RKF ..NPT
Typical panel cutout 22.5 mm
RSF ..NPT
We reserve the right to make technical alterations without prior notice.
Typical panel cutout 22.5 mm
RKF 511-*M/NPT RSF 511-*M/NPT
RKF 55-*M/NPT RSF 55-*M/NPT
RKF 56-*M/NPT RSF 56-*M/NPT
RKF 58-*M/NPT RSF 58-*M/NPT
RKF 61-*M/NPT RSF 61-*M/NPT
RKF 66-*M/NPT RSF 66-*M/NPT
RKF 68-*M/NPT RSF 68-*M/NPT
5x18 AWG, 105 °C, 9 A, automotive color code
5x16 AWG, 105 °C, 10 A, automotive color code
5x16 AWG, 105 °C, 10 A, heavy duty
5x18 AWG, 105 °C, 300 V, 9 A, heavy duty
6x18 AWG, 105 °C, 8 A, standard duty
6x16 AWG, 105 °C, 8 A, heavy duty
6x18 AWG, 105 °C, 600 V, 8 A, heavy duty
1. RD/WH
2. RD/BU
3. GN
4. RD/OG
5. RD/BK
1. WH
2. RD
3. GN
4. OG
5. BK
1. GN
2. WH
3. BU
4. GY
5. YE
6. BN
1. WH
2. RD
3. GN
4. OG
5. BK
6. BU
Receptacles
Male
Female
Male
Standard lead length is 0.3 meters. Consult factory for other lengths.
**
Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing. For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
B2007 F31
7/8” minifast® Connectivity Products
2, 3 and 4-Wire Receptacles, Front Mount, M20 Threads
y NEMA 1, 3, 4, 6P y IEC IP67 Protection y 600 V
Housing Style Female Part Number Male Part Number Features Pinout
RKF 20-*M/M20 RSF 20-*M/M20
2x18 AWG, 105 °C, 9 A, standard duty
1. BN
2. BU
Female/Male
RKF ..M20
Typical panel cutout 22.5 mm
RKF 26-*M/M20 RSF 26-*M/M20
RKF 30-*M/M20 RSF 30-*M/M20
RKF 31-*M/M20 RSF 31-*M/M20
RKF 311-*M/M20 RSF 311-*M/M20
RKF 35-*M/M20 RSF 35-*M/M20
RKF 36-*M/M20 RSF 36-*M/M20
RKF 40-*M/M20 RSF 40-*M/M20
2x16 AWG Leads, 105 °C, 10 A, heavy duty
3x18 AWG, 105 °C, 9 A standard duty
3x18 AWG, 105 °C, 9 A standard duty
3x18 AWG, 105 °C, 9 A automotive color code
3x16 AWG, 105 °C, 10 A, automotive color code
3x16 AWG, 105 °C, 10 A, heavy duty
4x18 AWG, 105 °C, 9 A standard duty
1. WH
2. BK
1. GY/YE
2. BN
3. BU
1. BK
2. BN
3. BU
1. GN
2. RD/BK
3. RD/WH
1. GN
2. BK
3. WH
1. BN
2. WH
3. BU
4. BK
Female
We reserve the right to make technical alterations without prior notice.
Male
Female
Male
RSF ..M20
Female
Typical panel cutout 22.5 mm
1. BK
RKF 46-*M/M20 RSF 46-*M/M20
Standard lead length is 0.3 meters. Consult factory for other lengths.
**
Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing. For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
4x16 AWG, 105 °C, 10 A heavy duty
2. WH
3. RD
4. GN
Male
F32 B2007 www.turck.com 1-800-544-7769 Fax: (763) 553-0708 Turck Minneapolis, MN 55441 B2007 F33
7/8” minifast® Connectivity Products
5 and 6-Wire Receptacles, Front Mount, M20 Threads
y
NEMA 1, 3, 4, 6P
y IEC IP67 Protection y 600 V
Housing Style Female Part Number Male Part Number Features Pinout
RKF 50-*M/M20 RSF 50-*M/M20
RKF ..M20
5x18 AWG, 105 °C, 9 A standard duty
1. BK
2. BU
3. GN/YE
4. BN
5. WH
Female
5x18 AWG, 105 °C,
RKF 511-*M/M20 RSF 511-*M/M20
Typical panel cutout 22.5 mm
RKF 55-*M/M20 RSF 55-*M/M20
RKF 56-*M/M20 RSF 56-*M/M20
RSF ..M20
RKF 61-*M/M20 RSF 61-*M/M20
Typical panel cutout 22.5 mm
We reserve the right to make technical alterations without prior notice.
Standard lead length is 0.3 meters. Consult factory for other lengths.
**
Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing. For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
RKF 66-*M/M20 RSF 66-*M/M20
9 A automotive color code
5x16 AWG, 105 °C, 10 A, automotive color code
5x16 AWG, 105 °C, 10 A, heavy duty
6x18 AWG, 105 °C, 8 A standard duty
6x16 AWG, 105 °C, 8 A heavy duty
1. RD/WH
2. RD/BU
3. GN
4. RD/OG
5. RD/BK
1. WH
2. RD
3. GN
4. OG
5. BK
1. GN
2. WH
3. BU
4. GY
5. YE
6. BN
1. WH
2. RD
3. GN
4. OG
5. BK
6. BU
Receptacles
Male
Female
Male
B2007 F33
1” minifast® Connectivity Products
6, 7 and 8-Wire Receptacles, Front Mount, M20 Threads
y NEMA 1, 3, 4, 6P y IEC IP68 Protection y 600 V, 8 A
Housing Style Female Part Number Male Part Number Features Pinout
RKF ..M20
RKF 6B6-*M/M20 RSF 6B6-*M/M20 6x16 AWG, 105 °C
1. OG
2. BU
3. BK
4. WH
5. RD
6. GN
Female
Male
Typical panel cutout 22.5 mm
RSF ..M20
Typical panel cutout 22.5 mm
RKF 76-*M/M20 RSF 76-*M/M20 7x16 AWG, 105 °C
RKF 86-*M/M20 RSF 86-*M/M20 8x16 AWG, 105 °C
1. WH/BK
2. BK
3. WH
4. RD
5. OG
6. BU
7. GN
1. OG
2. BU
3. WH/BK
4. BK
5. WH
6. RD
7. GN
8. RD/BK
We reserve the right to make technical alterations without prior notice.
Female
Male
Female
Male
Standard lead length is 0.3 meters. Consult factory for other lengths.
**
Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing. For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
F34 B2007 www.turck.com 1-800-544-7769 Fax: (763) 553-0708 Turck Minneapolis, MN 55441 B2007 F35
1 1/8” minifast® Connectivity Products
9, 10 and 12-Wire Receptacles, Front Mount, M20 Threads
y
NEMA 1, 3, 4, 6P
y IEC IP68 Protection y 600 V, 7 A
Housing Style Female Part Number Male Part Number Features Pinout
RKF 96-*M/M20 RSF 96-*M/M20 9x16 AWG, 105 °C
RKF ..M20
Typical panel cutout 22.5 mm
1. OG
2. BU
3. RD/BK
4. GN/BK
5. WH
6. RD
7. GN
8. WH/BK
9. BK
Female
Receptacles
Male
Female
1. OG
2. BU
3. WH/BK
4. RD/BK
RKF 106-*M/M20 RSF 106-*M/M20 10x16 AWG, 105 °C
We reserve the right to make technical alterations without prior notice.
RSF ..M20
Typical panel cutout 22.5 mm
RKF 126-*M/M20 RSF 126-*M/M20 12x16 AWG, 105 °C
5. GN/BK
6. OG/BK
7. RD
8. GN
9. BK
10. WH
1. OG
2. BU
3. WH/BK
4. RD/BK
5. GN/BK
6. OG/BK
7. BU/BK
8. BK/WH
9. GN
10. RD/BK
11. WH
12. BK
Male
Female
Male
Standard lead length is 0.3 meters. Consult factory for other lengths.
**
Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing. For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
B2007 F35
1” minifast® Connectivity Products
6, 7 and 8-Wire Receptacles, Front Mount
y NEMA 1, 3, 4, 6P y IEC IP68 Protection y 600 V, 8 A
Housing Style Female Part Number Male Part Number Features Pinout
RKF 6B6-*M/14.5/NPT RSF 6B6-*M/14.5/NPT
RKF ..1/2-14NPT
Typical panel cutout 22.5 mm
6x16 AWG, 105 °C, 1/2-14 NPT threads
1. OG
2. BU
3. BK
4. WH
5. RD
6. GN
Female
Male
We reserve the right to make technical alterations without prior notice.
RSF ..1/2-14NPT
Typical panel cutout 22.5 mm
RKF 76-*M/14.5/NPT RSF 76-*M/14.5/NPT
RKF 86-*M/14.5/NPT RSF 86-*M/14.5/NPT
7x16 AWG, 105 °C, 1/2-14 NPT threads
8x16 AWG, 105 °C, 1/2-14 NPT threads
1. WH/BK
2. BK
3. WH
4. RD
5. OG
6. BU
7. GN
1. OG
2. BU
3. WH/BK
4. BK
5. WH
6. RD
7. GN
8. RD/BK
Female
Male
Female
Male
Standard lead length is 0.3 meters. Consult factory for other lengths.
**
Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing. For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
F36 B2007 www.turck.com 1-800-544-7769 Fax: (763) 553-0708 Turck Minneapolis, MN 55441 B2007 F37
1” minifast® Connectivity Products
6, 7 and 8-Wire Receptacles, Front Mount
y
NEMA 1, 3, 4, 6P
y IEC IP68 Protection y 600 V, 8 A
Housing Style Female Part Number Male Part Number Features Pinout
RKF ..3/4-14NPT
RKF 6B6-*M/14.75/NPT RSF 6B6-*M/14.75/NPT
6x16 AWG, 105 °C, 3/4-14 NPT threads
1. OG
2. BU
3. BK
4. WH
5. RD
6. GN
Female
Receptacles
Male
Typical panel cutout 22.5 mm
Female
1. WH/BK
2. BK
RKF 76-*M/14.75/NPT RSF 76-*M/14.75/NPT
We reserve the right to make technical alterations without prior notice.
RSF ..3/4-14NPT
Typical panel cutout 22.5 mm
RKF 86-*M/14.75/NPT RSF 86-*M/14.75/NPT
7x16 AWG, 105 °C, 3/4-14 NPT threads
8x16 AWG, 105 °C, 3/4-14 NPT threads
3. WH
4. RD
5. OG
6. BU
7. GN
1. OG
2. BU
3. WH/BK
4. BK
5. WH
6. RD
7. GN
8. RD/BK
Male
Female
Male
Standard lead length is 0.3 meters. Consult factory for other lengths.
**
Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing. For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
B2007 F37
1 1/8” minifast® Connectivity Products
9, 10 and 12-Wire Receptacles, Front Mount
y NEMA 1, 3, 4, 6P y IEC IP68 Protection y 600 V, 7 A
Housing Style Female Part Number Male Part Number Features Pinout
RKF 96-*M/14.5/NPT RSF 96-*M/14.5/NPT
RKF ...1/2-14NPT
9x16 AWG, 105 °C, 1/2-14 NPT threads
1. OG
2. BU
3. RD/BK
4. GN/BK
5. WH
6. RD
7. GN
8. WH/BK
9. BK
Female
Male
Typical panel cutout 22.5 mm
RSF ..1/2-14NPT
Typical panel cutout 22.5 mm
RKF 106-*M/14.5/NPT RSF 106-*M/14.5/NPT
RKF 126-*M/14.5/NPT RSF 126-*M/14.5/NPT
10x16 AWG, 105 °C, 1/2-14 NPT threads
12x16 AWG, 105 °C, 1/2-14 NPT threads
1. OG
2. BU
3. WH/BK
4. RD/BK
5. GN/BK
6. OG/BK
7. RD
8. GN
9. BK
10. WH
1. OG
2. BU
3. WH/BK
4. RD/BK
5. GN/BK
6. OG/BK
7. BU/BK
8. BK/WH
9. GN
10. RD
11. WH
12. BK
We reserve the right to make technical alterations without prior notice.
Female
Male
Female
Male
Standard lead length is 0.3 meters. Consult factory for other lengths.
**
Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing. For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
F38 B2007 www.turck.com 1-800-544-7769 Fax: (763) 553-0708 Turck Minneapolis, MN 55441 B2007 F39
1 1/8” minifast® Connectivity Products
9, 10 and 12-Wire Receptacles, Front Mount
y
NEMA 1, 3, 4, 6P
y IEC IP68 Protection y 600 V, 7 A
Housing Style Female Part Number Male Part Number Features Pinout
RKF 96-*M/14.75/NPT RSF 96-*M/14.75/NPT
RKF ..3/4-14NPT
Typical panel cutout 22.5 mm
9x16 AWG, 105 °C, 3/4-14 NPT threads
1. OG
2. BU
3. RD/BK
4. GN/BK
5. WH
6. RD
7. GN
8. WH/BK
9. BK
Female
Receptacles
Male
Female
1. OG
2. BU
3. WH/BK
4. RD/BK
RKF 106-*M/14.75/NPT RSF 106-*M/14.75/NPT
We reserve the right to make technical alterations without prior notice.
RSF ..3/4-14NPT
Typical panel cutout 22.5 mm
RKF 126-*M/14.75/NPT RSF 126-*M/14.75/NPT
10x16 AWG, 105 °C, 3/4-14 NPT threads
12x16 AWG, 105 °C, 3/4-14 NPT threads
5. GN/BK
6. OG/BK
7. RD
8. GN
9. BK
10. WH
1. OG
2. BU
3. WH/BK
4. RD/BK
5. GN/BK
6. OG/BK
7. BU/BK
8. BK/WH
9. GN
10. RD
11. WH
12. BK
Male
Female
Male
Standard lead length is 0.3 meters. Consult factory for other lengths.
**
Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing. For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
B2007 F39
1 1/8” minifast® Connectivity Products
19-Wire Receptacles, Front Mount
y NEMA 1, 3, 4, 6P y IEC IP68 Protection y 300 V, 4 A (pins 5, 7, 12), 2 A (all
others)
Housing Style Female Part Number Male Part Number Features Pinout
RSF ..1/2-14NPT
Typical panel cutout 22.5 mm
RKF ...1/2-14NPT
Typical panel cutout 22.5 mm
RSF ..3/4-14NPT
Typical panel cutout 22.5 mm
RKF ..3/4-14NPT
RKF 190-*M/14.5/NPT RSF 190-*M/14.5/NPT
RKF 190-*M/14.75/NPT RSF 190-*M/14.75/NPT
3x18, 16x22 AWG, 105 °C, 1/2-14 NPT threads
3x18, 16x22 AWG 105 °C, 3/4-14 NPT threads
1. VT
2. RD
3. GY
4. RD/BU
5. BU
6. GN
7. BN
8. WH/GN
9. WH/YE
10. WH/GY
11. BK
12. GN/YE
13. YE/BN
14. BN/GN
15. WH
16. YE
17. PK
18. GY/BN
19. GY/PK
Female
We reserve the right to make technical alterations without prior notice.
Male
Typical panel cutout 22.5 mm
Standard lead length is 0.3 meters. Consult factory for other lengths.
**
Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing. For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
F40 B2007 www.turck.com 1-800-544-7769 Fax: (763) 553-0708 Turck Minneapolis, MN 55441 B2007 F41
1 1/8” minifast® Connectivity Products
19-Wire Receptacles, Front Mount
y
NEMA 1, 3, 4, 6P
y IEC IP68 Protection y 300 V, 4 A (pins 5, 7, 12), 2 A (all
others)
Housing Style Female Part Number Male Part Number Features Pinout
RKF ..PG16
Typical panel cutout 22.5 mm
3x18, 16x22 AWG,
RKF 190-*M/PG 16 RSF 190-*M/PG 16
RSF ..PG16
Typical panel cutout 22.5 mm
RKF ...M20
We reserve the right to make technical alterations without prior notice.
Typical panel cutout 22.5 mm
RKF 190-*M/M20 RSF 190-*M/M20
RSF ..M20
105 °C, PG 16 threads
3x18, 16x22 AWG, 105 °C, M20 threads
1. VT
2. RD
3. GY
4. RD/BU
5. BU
6. GN
7. BN
8. WH/GN
9. WH/YE
10. WH/GY
11. BK
12. GN/YE
13. YE/BN
14. BN/GN
15. WH
16. YE
17. PK
18. GY/BN
19. GY/PK
Female
Male
Receptacles
Typical panel cutout 22.5 mm
Standard lead length is 0.3 meters. Consult factory for other lengths.
**
Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing. For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
B2007 F41
7/8” minifast® Connectivity Products
2 and 3-Wire Receptacles, Back Panel Mount
y NEMA 1, 3, 4, 6P y IEC IP68 Protection y 600 V
Housing Style Female Part Number Male Part Number Features Pinout
RKFP ..
RKFP Cutout
Recommended maximum panel thickness is 6.4 mm
RSFP ..
RKFP 20-*M RSFP 20-*M
RKFP 26-*M RSFP 26-*M
RKFP 30-*M RSFP 30-*M
RKFP 31-*M RSFP 31-*M
RKFP 311-*M RSFP 311-*M
RKFP 35-*M RSFP 35-*M
2x18 AWG, 105 °C, 9 A, M30x1.5 threads, standard duty
2x16 AWG, 105 °C, 10 A, M30x1.5 threads, heavy duty
3x18 AWG, 105 °C, 9 A, M30x1.5 threads, standard duty
3x18 AWG, 105 °C, 9 A, M30x1.5 threads, standard duty
3x18 AWG, 105 °C, 9 A, M30x1.5 threads, automotive color code
3x16 AWG, 105 °C, 10 A, automotive color code, M30x1.5 Threads
1. BN
2. BU
1. WH
2. BK
1. GN/YE
2. BN
3. BU
1. BK
2. BN
3. BU
1. GN
2. RD/BK
3. RD/WH
Female/Male
We reserve the right to make technical alterations without prior notice.
Female
Male
RSFP Cutout
Recommended maximum panel thickness is 6.4 mm
RKFP 36-*M RSFP 36-*M
Standard lead length is 0.3 meters. Consult factory for other lengths.
**
Standard housing material is nickel plated brass.. “RSFP ..”; “RSFPV ..” indicates stainless steel housing. To specify PVC jacketed cable, add “/S717” to the end of the part number.
3x16 AWG, 105 °C, 10 A, M30x1.5 threads, heavy duty
1. GN
2. BK
3. WH
F42 B2007 www.turck.com 1-800-544-7769 Fax: (763) 553-0708 Turck Minneapolis, MN 55441 B2007 F43
7/8” minifast® Connectivity Products
4-Wire Receptacles, Back Panel Mount
y
NEMA 1, 3, 4, 6P
y IEC IP68 Protection y 600 V
Housing Style Female Part Number Male Part Number Features Pinout
RKFP ..
RKFP Cutout
Recommended maximum panel thickness is 6.4 mm
RSFP ..
We reserve the right to make technical alterations without prior notice.
RKFP 40-*M RSFP 40-*M
RKFP 46-*M RSFP 46-*M
4x18 AWG, 105 °C, 9 A, M30x1.5 Threads, Standard Duty
4x16 AWG, 105 °C, 10 A, M30x1.5 Threads, Heavy Duty
1. BN
2. WH
3. BU
4. BK
1. BK
2. WH
3. RD
4. GN
Female
Receptacles
Male
Female
Male
RSFP Cutout
Recommended maximum panel thickness is 6.4 mm
Standard lead length is 0.3 meters. Consult factory for other lengths.
**
Standard housing material is nickel plated brass.. “RSFP ..”; “RSFPV ..” indicates stainless steel housing. To specify PVC jacketed cable, add “/S717” to the end of the part number.
B2007 F43
7/8” minifast® Connectivity Products
5 and 6-Wire Receptacles, Back Panel Mount
y NEMA 1, 3, 4, 6P y IEC IP68 Protection y 600 V
Housing Style Female Part Number Male Part Number Features Pinout
RKFP 50-*M RSFP 50-*M
RKFP ..
RKFP 511-*M RSFP 511-*M
RKFP Cutout
Recommended maximum panel thickness is 6.4 mm
RKFP 55-*M RSFP 55-*M
5x18 AWG, 105 °C, 9 A, M30x1.5 Threads, Standard Duty
5x18 AWG, 105 °C, 9 A, Automotive Color Code, M30x1.5 Threads
5x16 AWG, 105 °C, 10 A, Automotive Color Code, M30x1.5 Threads
1. BK
2. BU
3. GN/YE
4. BN
5. WH
1. RD/WH
2. RD/BU
3. GN
4. RD/OG
5. RD/BK
Female
We reserve the right to make technical alterations without prior notice.
Male
RKFP 56-*M RSFP 56-*M
RSFP ..
RKFP 61-*M RSFP 61-*M
RKFP 66-*M RSFP 66-*M
RSFP Cutout
Recommended maximum panel thickness is 6.4 mm
RKFP 68-*M RSFP 68-*M
Standard lead length is 0.3 meters. Consult factory for other lengths.
**
Standard housing material is nickel plated brass.. “RSFP ..”; “RSFPV ..” indicates stainless steel housing. To specify PVC jacketed cable, add “/S717” to the end of the part number.
5x16 AWG, 105 °C, 10 A, M30x1.5 Threads, Heavy Duty
6x18 AWG, 105 °C, 8 A, M30x1.5 Threads, Standard Duty
6x16 AWG 105 °C, 8 A, M30x1.5 Threads, Heavy Duty
6x18 AWG 105 °C, 8 A, M30x1.5 Threads, Heavy Duty
1. WH
2. RD
3. GN
4. OG
5. BK
1. GN
2. WH
3. BU
4. GY
5. YE
6. BN
1. WH
2. RD
3. GN
4. OG
5. BK
6. BU
Female
Male
F44 B2007 www.turck.com 1-800-544-7769 Fax: (763) 553-0708 Turck Minneapolis, MN 55441 B2007 F45
7/8” minifast® Connectivity Products
PCB Pins Receptacles
y
NEMA 1, 3, 4, 6P
y IEC IP67 Protection y 600 V, 9 A
Housing Style Female Part Number Male Part Number Features Pinout
RKF ..PCB
Female
RKF 40-PCB RSF 40-PCB
RSF ..PCB
RKF 50-PCB RSF 50-PCB
** Standard housing material is nickel plated brass.. “RSFL ..”; “RSFVL ..” indicates stainless steel housing. No stainless option for “PCB”.
For locknuts to be included, add “W/LN” to the end of the part number.
We reserve the right to make technical alterations without prior notice.
4-pin PCB Pins, 105 °C, PG 11 Threads
5-pin PCB Pins, 105 °C, PG 11 Threads
Male
Female
Male
Receptacles
4-pin PCB Board Layout 5-pin PCB Board Layout
B2007 F45
7/8” minifast® Connectivity Products
Solder Cup Receptacles
y NEMA 1, 3, 4, 6P y IEC IP67 Protection y 600 V, 9 A
Housing Style Female Part Number Male Part Number Features Pinout
RKFL 26 RSFL 26
Female/Male
2-pin solder cups, 105 °C,1/2-14 NPSM Threads
RKFL ..
RSFL ..
RKFL 36 RSFL 36
RKFL 46 RSFL 46
RKFL 56 RSFL 56
RKFL 66 RSFL 66
3-pin solder cups, 105 °C,1/2-14 NPSM Threads
4-pin solder cups 105 °C, 1/2-14 NPSM Threads
5-pin solder cups 105 °C, 1/2-14 NPSM Threads
6-pin solder cups 105 °C, 1/2-14 NPSM Threads
Female
Female
Female Male
Female
Male
Male
Male
We reserve the right to make technical alterations without prior notice.
** Standard housing material is nickel plated brass.. “RSFL ..”; “RSFVL ..” indicates stainless steel housing. No stainless option for “PCB”.
For locknuts to be included, add “W/LN” to the end of the part number.
4-pin PCB Board Layout 5-pin PCB Board Layout
F46 B2007 www.turck.com 1-800-544-7769 Fax: (763) 553-0708 Turck Minneapolis, MN 55441 B2007 F47
7/8” minifast® Connectivity Products
Bulkhead Feed-Thru Receptacles
y
NEMA 1, 3, 4, 6P
y IEC IP67 Protection y 600 V, 9 A
Housing Style Part Number Features Pinout
RSF RKF ..**
Note: Recommended maximum panel thickness is 22.2 mm
We reserve the right to make technical alterations without prior notice.
RSF RKF 20/22
RSF RKF 30/22
RSF RKF 40/22
RSF RKF 50/22
RSF RKF 60/22
Nickel plated brass 2-pin, 105 °C, thrust washer and panel keyway prevent rotation
Nickel plated brass 3-pin, 105 °C, thrust washer and panel keyway prevent rotation
Nickel plated brass 4-pin, 105 °C, thrust washer and panel keyway prevent rotation
Nickel plated brass 5-pin, 105 °C, thrust washer and panel keyway prevent rotation
Nickel plated brass 6-pin, 105 °C, thrust washer and panel keyway prevent rotation
Female
Female
Female
Female Male
Female
Male
Male
Male
Male
Receptacles
** Standard housing material is nickel plated brass .. “RSF RKF..”; “RSFV RKFV..” indicates stainless steel housing.
B2007 F47