We reserve the right to make technical alterations without prior notice.
Rear Mount
PCB Mount
M30F42
Bulkhead Feed-thruF47
PCB PinsF45
7/8” minifast® Connectivity Products
2 and 3-Wire Receptacles, Front Mount, 1/2-14 NPSM Threads
y
NEMA 1, 3, 4, 6P
y IEC IP67 Protection
Housing StyleFemale Part NumberMale Part NumberFeaturesPinout
RKF ..
Typical panel cutout 22.5 mm
RSF ..
RKF 20-*MRSF 20-*M
RKF 26-*MRSF 26-*M
RKF 28-*MRSF 28-*M
RKF 30-*MRSF 30-*M
RKF 31-*MRSF 31-*M
RKF 311-*MRSF 311-*M
RKF 35-*MRSF 35-*M
2x18 AWG 105 °C, 600 V,
9 A, standard duty
2x16 AWG Leads, 105 °C,
600 V, 10 A, heavy duty
2x18 AWG, 105 °C, 600 V,
9 A, heavy duty
3x18 AWG, 105 °C, 600 V,
9 A, standard duty
3x18 AWG, 105 °C, 600 V,
9 A, standard duty
3x18 AWG, 105 °C, 600 V,
9 A, automotive color
code
3x16 AWG, 105 °C, 600 V,
10 A, automotive color
code
1. BN
2. BU
1. WH
2. BK
1. WH
2. BK
1. GY/YE
2. BN
3. BU
1. BK
2. BN
3. BU
1. GN
2. RD/BK
3. RD/WH
Female/Male
Receptacles
Female
Male
We reserve the right to make technical alterations without prior notice.
**
Typical panel cutout 22.5 mm
Standard lead length is 0.3 meters. Consult factory for other lengths.
Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing.
For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
B2007 F25
RKF 36-*MRSF 36-*M
RKF 38-*MRSF 38-*M
3x16 AWG, 105 °C, 600 V,
10 A, heavy duty
3x18 AWG, 105 °C, 600 V,
9 A, heavy duty
1. GN
2. BK
3. WH
1. GN
2. BK
3. WH
7/8” minifast® Connectivity Products
4-Wire Receptacles, Front Mount, 1/2-14 NPSM Threads
y NEMA 1, 3, 4, 6Py IEC IP67 Protection
Housing StyleFemale Part NumberMale Part NumberFeaturesPinout
Female
RKF ..
Typical panel cutout 22.5 mm
RSF ..
RKF 40-*MRSF 40-*M
RKF 46-*MRSF 46-*M
4x18 AWG 105 °C, 600 V,
9 A, standard duty
4x16 AWG, 105 °C, 600 V,
10 A, heavy duty
1. BN
2. WH
3. BU
4. BK
1. BK
2. WH
3. RD
4. GN
Male
We reserve the right to make technical alterations without prior notice.
Female
Male
Female
Typical panel cutout 22.5 mm
RKF 48-*MRSF 48-*M
Standard lead length is 0.3 meters. Consult factory for other lengths.
**
Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing.
For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
5-Wire Receptacles, Front Mount, 1/2-14 NPSM Threads
y
NEMA 1, 3, 4, 6P
y IEC IP67 Protection
Housing StyleFemale Part NumberMale Part NumberFeaturesPinout
RKF 50-*MRSF 50-*M
RKF ..
5x18 AWG, 105 °C, 600 V,
9 A, standard duty
1. BK
2. BU
3. GN/YE
4. BN
5. WH
Female
5x18 AWG, 105 °C, 600 V,
Typical panel cutout 22.5 mm
RSF ..
Typical panel cutout 22.5 mm
Standard lead length is 0.3 meters. Consult factory for other lengths.
We reserve the right to make technical alterations without prior notice.
**
Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing.
For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
RKF 511-*MRSF 511-*M
RKF 55-*MRSF 55-*M
RKF 56-*MRSF 56-*M
RKF 58-*MRSF 58-*M
9 A, automotive color
code
5x16 AWG, 105 °C, 600 V,
10 A, automotive color
code
5x16 AWG, 105 °C, 600 V,
10 A, heavy duty
5x18 AWG, 105 °C, 300 V,
9 A, heavy duty
1. RD/WH
2. RD/BU
3. GN
4. RD/OG
5. RD/BK
1. RD/WH
2. RD/BU
3. GN
4. RD/OG
5. RD/BK
1. WH
2. RD
3. GN
4. OG
5. BK
Receptacles
Male
B2007 F27
7/8” minifast® Connectivity Products
6-Wire Receptacles, Front Mount, 1/2-14 NPSM Threads
y NEMA 1, 3, 4, 6Py IEC IP67 Protection
Housing StyleFemale Part NumberMale Part NumberFeaturesPinout
RKF ..
RKF 61-*MRSF 61-*M
Typical panel cutout 22.5 mm
RKF 66-*MRSF 66-*M
RSF ..
RKF 68-*MRSF 68-*M
Typical panel cutout 22.5 mm
Standard lead length is 0.3 meters. Consult factory for other lengths.
**
Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing.
For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
6x18 AWG, 105 °C, 600 V,
8 A, standard threads
6x16 AWG, 105 °C, 600 V,
8 A, heavy duty
6x18 AWG, 105 °C, 600 V,
8 A, heavy duty
1. GN
2. WH
3. BU
4. Gy
5. YE
6. BN
1. WH
2. RD
3. GN
4. OG
5. BK
6. BU
Female
Male
We reserve the right to make technical alterations without prior notice.
2 and 3-Wire Receptacles, Front Mount, 1/2-14 NPT Threads
y
NEMA 1, 3, 4, 6P
y IEC IP67 Protection
Housing StyleFemale Part NumberMale Part NumberFeaturesPinout
RKF ..NPT
Typical panel cutout 22.5 mm
RSF ..NPT
RKF 20-*M/NPTRSF 20-*M/NPT
RKF 26-*M/NPTRSF 26-*M/NPT
RKF 28-*M/NPTRSF 28-*M/NPT
RKF 30-*M/NPTRSF 30-*M/NPT
RKF 31-*M/NPTRSF 31-*M/NPT
RKF 311-*M/NPTRSF 311-*M/NPT
RKF 35-*M/NPTRSF 35-*M/NPT
2x18 AWG, 105 °C, 9 A,
standard duty
2x16 AWG Leads, 105 °C,
10 A, heavy duty
2x18 AWG, 105 °C, 600 V,
9 A, heavy duty
3x18 AWG, 105 °C, 9 A,
standard duty
3x18 AWG, 105 °C, 9 A,
standard duty
3x18 AWG, 105 °C, 9 A,
automotive color code
3x16 AWG, 105 °C, 10 A,
automotive color code
1. BN
2. BU
1. WH
2. BK
1. WH
2. BK
1. GY/YE
2. BN
3. BU
1. BK
2. BN
3. BU
1. GN
2. RD/BK
3. RD/WH
Female/Male
Receptacles
Female
Male
We reserve the right to make technical alterations without prior notice.
**
Typical panel cutout 22.5 mm
Standard lead length is 0.3 meters. Consult factory for other lengths.
Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing.
For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
B2007 F29
RKF 36-*M/NPTRSF 36-*M/NPT
RKF 38-*M/NPTRSF 38-*M/NPT
3x16 AWG, 105 °C, 10 A,
heavy duty
3x18 AWG, 105 °C, 600 V,
9 A, heavy duty
1. GN
2. BK
3. WH
1. GN
2. BK
3. WH
7/8” minifast® Connectivity Products
4-Wire Receptacles, Front Mount, 1/2-14 NPT Threads
y NEMA 1, 3, 4, 6Py IEC IP67 Protectiony 600 V
Housing StyleFemale Part NumberMale Part NumberFeaturesPinout
RKF ..NPT
Typical panel cutout 22.5 mm
RKF 40-*M/NPTRSF 40-*M/NPT
4x18 AWG, 105 °C, 9 A,
standard duty
1. BN
2. WH
3. BU
4. BK
Female
Male
Female
We reserve the right to make technical alterations without prior notice.
RKF 46-*M/NPTRSF 46-*M/NPT
RSF ..NPT
Typical panel cutout 22.5 mm
Standard lead length is 0.3 meters. Consult factory for other lengths.
**
Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing.
For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
5 and 6-Wire Receptacles, Front Mount, 1/2-14 NPT Threads
y
NEMA 1, 3, 4, 6P
y IEC IP67 Protectiony 600 V
Housing StyleFemale Part NumberMale Part NumberFeaturesPinout
RKF 50-*M/NPTRSF 50-*M/NPT
5x18 AWG, 105 °C, 9 A,
standard duty
1. BK
2. BU
3. GN/YE
4. BN
5. WH
Female
RKF ..NPT
Typical panel cutout 22.5 mm
RSF ..NPT
We reserve the right to make technical alterations without prior notice.
Typical panel cutout 22.5 mm
RKF 511-*M/NPTRSF 511-*M/NPT
RKF 55-*M/NPTRSF 55-*M/NPT
RKF 56-*M/NPTRSF 56-*M/NPT
RKF 58-*M/NPTRSF 58-*M/NPT
RKF 61-*M/NPTRSF 61-*M/NPT
RKF 66-*M/NPTRSF 66-*M/NPT
RKF 68-*M/NPTRSF 68-*M/NPT
5x18 AWG, 105 °C, 9 A,
automotive color code
5x16 AWG, 105 °C, 10 A,
automotive color code
5x16 AWG, 105 °C, 10 A,
heavy duty
5x18 AWG, 105 °C, 300 V,
9 A, heavy duty
6x18 AWG, 105 °C, 8 A,
standard duty
6x16 AWG, 105 °C, 8 A,
heavy duty
6x18 AWG, 105 °C, 600 V,
8 A, heavy duty
1. RD/WH
2. RD/BU
3. GN
4. RD/OG
5. RD/BK
1. WH
2. RD
3. GN
4. OG
5. BK
1. GN
2. WH
3. BU
4. GY
5. YE
6. BN
1. WH
2. RD
3. GN
4. OG
5. BK
6. BU
Receptacles
Male
Female
Male
Standard lead length is 0.3 meters. Consult factory for other lengths.
**
Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing.
For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
B2007 F31
7/8” minifast® Connectivity Products
2, 3 and 4-Wire Receptacles, Front Mount, M20 Threads
y NEMA 1, 3, 4, 6Py IEC IP67 Protectiony 600 V
Housing StyleFemale Part NumberMale Part NumberFeaturesPinout
RKF 20-*M/M20RSF 20-*M/M20
2x18 AWG, 105 °C, 9 A,
standard duty
1. BN
2. BU
Female/Male
RKF ..M20
Typical panel cutout 22.5 mm
RKF 26-*M/M20RSF 26-*M/M20
RKF 30-*M/M20RSF 30-*M/M20
RKF 31-*M/M20RSF 31-*M/M20
RKF 311-*M/M20RSF 311-*M/M20
RKF 35-*M/M20RSF 35-*M/M20
RKF 36-*M/M20RSF 36-*M/M20
RKF 40-*M/M20RSF 40-*M/M20
2x16 AWG Leads, 105 °C,
10 A, heavy duty
3x18 AWG, 105 °C, 9 A
standard duty
3x18 AWG, 105 °C, 9 A
standard duty
3x18 AWG, 105 °C, 9 A
automotive color code
3x16 AWG, 105 °C, 10 A,
automotive color code
3x16 AWG, 105 °C, 10 A,
heavy duty
4x18 AWG, 105 °C, 9 A
standard duty
1. WH
2. BK
1. GY/YE
2. BN
3. BU
1. BK
2. BN
3. BU
1. GN
2. RD/BK
3. RD/WH
1. GN
2. BK
3. WH
1. BN
2. WH
3. BU
4. BK
Female
We reserve the right to make technical alterations without prior notice.
Male
Female
Male
RSF ..M20
Female
Typical panel cutout 22.5 mm
1. BK
RKF 46-*M/M20RSF 46-*M/M20
Standard lead length is 0.3 meters. Consult factory for other lengths.
**
Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing.
For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
5 and 6-Wire Receptacles, Front Mount, M20 Threads
y
NEMA 1, 3, 4, 6P
y IEC IP67 Protectiony 600 V
Housing StyleFemale Part NumberMale Part NumberFeaturesPinout
RKF 50-*M/M20RSF 50-*M/M20
RKF ..M20
5x18 AWG, 105 °C,
9 A standard duty
1. BK
2. BU
3. GN/YE
4. BN
5. WH
Female
5x18 AWG, 105 °C,
RKF 511-*M/M20RSF 511-*M/M20
Typical panel cutout 22.5 mm
RKF 55-*M/M20RSF 55-*M/M20
RKF 56-*M/M20RSF 56-*M/M20
RSF ..M20
RKF 61-*M/M20RSF 61-*M/M20
Typical panel cutout 22.5 mm
We reserve the right to make technical alterations without prior notice.
Standard lead length is 0.3 meters. Consult factory for other lengths.
**
Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing.
For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
RKF 66-*M/M20RSF 66-*M/M20
9 A automotive
color code
5x16 AWG, 105 °C,
10 A, automotive
color code
5x16 AWG, 105 °C,
10 A, heavy duty
6x18 AWG, 105 °C,
8 A standard duty
6x16 AWG, 105 °C,
8 A heavy duty
1. RD/WH
2. RD/BU
3. GN
4. RD/OG
5. RD/BK
1. WH
2. RD
3. GN
4. OG
5. BK
1. GN
2. WH
3. BU
4. GY
5. YE
6. BN
1. WH
2. RD
3. GN
4. OG
5. BK
6. BU
Receptacles
Male
Female
Male
B2007 F33
1” minifast® Connectivity Products
6, 7 and 8-Wire Receptacles, Front Mount, M20 Threads
y NEMA 1, 3, 4, 6Py IEC IP68 Protectiony 600 V, 8 A
Housing StyleFemale Part NumberMale Part NumberFeaturesPinout
RKF ..M20
RKF 6B6-*M/M20RSF 6B6-*M/M206x16 AWG, 105 °C
1. OG
2. BU
3. BK
4. WH
5. RD
6. GN
Female
Male
Typical panel cutout 22.5 mm
RSF ..M20
Typical panel cutout 22.5 mm
RKF 76-*M/M20RSF 76-*M/M207x16 AWG, 105 °C
RKF 86-*M/M20RSF 86-*M/M208x16 AWG, 105 °C
1. WH/BK
2. BK
3. WH
4. RD
5. OG
6. BU
7. GN
1. OG
2. BU
3. WH/BK
4. BK
5. WH
6. RD
7. GN
8. RD/BK
We reserve the right to make technical alterations without prior notice.
Female
Male
Female
Male
Standard lead length is 0.3 meters. Consult factory for other lengths.
**
Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing.
For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
9, 10 and 12-Wire Receptacles, Front Mount, M20 Threads
y
NEMA 1, 3, 4, 6P
y IEC IP68 Protectiony 600 V, 7 A
Housing StyleFemale Part NumberMale Part NumberFeaturesPinout
RKF 96-*M/M20RSF 96-*M/M209x16 AWG, 105 °C
RKF ..M20
Typical panel cutout 22.5 mm
1. OG
2. BU
3. RD/BK
4. GN/BK
5. WH
6. RD
7. GN
8. WH/BK
9. BK
Female
Receptacles
Male
Female
1. OG
2. BU
3. WH/BK
4. RD/BK
RKF 106-*M/M20RSF 106-*M/M2010x16 AWG, 105 °C
We reserve the right to make technical alterations without prior notice.
RSF ..M20
Typical panel cutout 22.5 mm
RKF 126-*M/M20RSF 126-*M/M2012x16 AWG, 105 °C
5. GN/BK
6. OG/BK
7. RD
8. GN
9. BK
10. WH
1. OG
2. BU
3. WH/BK
4. RD/BK
5. GN/BK
6. OG/BK
7. BU/BK
8. BK/WH
9. GN
10. RD/BK
11. WH
12. BK
Male
Female
Male
Standard lead length is 0.3 meters. Consult factory for other lengths.
**
Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing.
For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
B2007 F35
1” minifast® Connectivity Products
6, 7 and 8-Wire Receptacles, Front Mount
y NEMA 1, 3, 4, 6Py IEC IP68 Protectiony 600 V, 8 A
Housing StyleFemale Part NumberMale Part NumberFeaturesPinout
RKF 6B6-*M/14.5/NPTRSF 6B6-*M/14.5/NPT
RKF ..1/2-14NPT
Typical panel cutout 22.5 mm
6x16 AWG, 105 °C,
1/2-14 NPT threads
1. OG
2. BU
3. BK
4. WH
5. RD
6. GN
Female
Male
We reserve the right to make technical alterations without prior notice.
RSF ..1/2-14NPT
Typical panel cutout 22.5 mm
RKF 76-*M/14.5/NPTRSF 76-*M/14.5/NPT
RKF 86-*M/14.5/NPTRSF 86-*M/14.5/NPT
7x16 AWG, 105 °C,
1/2-14 NPT threads
8x16 AWG, 105 °C,
1/2-14 NPT threads
1. WH/BK
2. BK
3. WH
4. RD
5. OG
6. BU
7. GN
1. OG
2. BU
3. WH/BK
4. BK
5. WH
6. RD
7. GN
8. RD/BK
Female
Male
Female
Male
Standard lead length is 0.3 meters. Consult factory for other lengths.
**
Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing.
For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
Housing StyleFemale Part NumberMale Part NumberFeaturesPinout
RKF ..3/4-14NPT
RKF 6B6-*M/14.75/NPT RSF 6B6-*M/14.75/NPT
6x16 AWG, 105 °C,
3/4-14 NPT threads
1. OG
2. BU
3. BK
4. WH
5. RD
6. GN
Female
Receptacles
Male
Typical panel cutout 22.5 mm
Female
1. WH/BK
2. BK
RKF 76-*M/14.75/NPTRSF 76-*M/14.75/NPT
We reserve the right to make technical alterations without prior notice.
RSF ..3/4-14NPT
Typical panel cutout 22.5 mm
RKF 86-*M/14.75/NPTRSF 86-*M/14.75/NPT
7x16 AWG, 105 °C,
3/4-14 NPT threads
8x16 AWG, 105 °C,
3/4-14 NPT threads
3. WH
4. RD
5. OG
6. BU
7. GN
1. OG
2. BU
3. WH/BK
4. BK
5. WH
6. RD
7. GN
8. RD/BK
Male
Female
Male
Standard lead length is 0.3 meters. Consult factory for other lengths.
**
Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing.
For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
B2007 F37
1 1/8” minifast® Connectivity Products
9, 10 and 12-Wire Receptacles, Front Mount
y NEMA 1, 3, 4, 6Py IEC IP68 Protectiony 600 V, 7 A
Housing StyleFemale Part NumberMale Part NumberFeaturesPinout
RKF 96-*M/14.5/NPTRSF 96-*M/14.5/NPT
RKF ...1/2-14NPT
9x16 AWG, 105 °C,
1/2-14 NPT threads
1. OG
2. BU
3. RD/BK
4. GN/BK
5. WH
6. RD
7. GN
8. WH/BK
9. BK
Female
Male
Typical panel cutout 22.5 mm
RSF ..1/2-14NPT
Typical panel cutout 22.5 mm
RKF 106-*M/14.5/NPTRSF 106-*M/14.5/NPT
RKF 126-*M/14.5/NPTRSF 126-*M/14.5/NPT
10x16 AWG, 105 °C,
1/2-14 NPT threads
12x16 AWG, 105 °C,
1/2-14 NPT threads
1. OG
2. BU
3. WH/BK
4. RD/BK
5. GN/BK
6. OG/BK
7. RD
8. GN
9. BK
10. WH
1. OG
2. BU
3. WH/BK
4. RD/BK
5. GN/BK
6. OG/BK
7. BU/BK
8. BK/WH
9. GN
10. RD
11. WH
12. BK
We reserve the right to make technical alterations without prior notice.
Female
Male
Female
Male
Standard lead length is 0.3 meters. Consult factory for other lengths.
**
Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing.
For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
Housing StyleFemale Part NumberMale Part NumberFeaturesPinout
RKF 96-*M/14.75/NPTRSF 96-*M/14.75/NPT
RKF ..3/4-14NPT
Typical panel cutout 22.5 mm
9x16 AWG, 105 °C,
3/4-14 NPT threads
1. OG
2. BU
3. RD/BK
4. GN/BK
5. WH
6. RD
7. GN
8. WH/BK
9. BK
Female
Receptacles
Male
Female
1. OG
2. BU
3. WH/BK
4. RD/BK
RKF 106-*M/14.75/NPT RSF 106-*M/14.75/NPT
We reserve the right to make technical alterations without prior notice.
RSF ..3/4-14NPT
Typical panel cutout 22.5 mm
RKF 126-*M/14.75/NPT RSF 126-*M/14.75/NPT
10x16 AWG, 105 °C,
3/4-14 NPT threads
12x16 AWG, 105 °C,
3/4-14 NPT threads
5. GN/BK
6. OG/BK
7. RD
8. GN
9. BK
10. WH
1. OG
2. BU
3. WH/BK
4. RD/BK
5. GN/BK
6. OG/BK
7. BU/BK
8. BK/WH
9. GN
10. RD
11. WH
12. BK
Male
Female
Male
Standard lead length is 0.3 meters. Consult factory for other lengths.
**
Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing.
For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
B2007 F39
1 1/8” minifast® Connectivity Products
19-Wire Receptacles, Front Mount
y NEMA 1, 3, 4, 6Py IEC IP68 Protectiony 300 V, 4 A (pins 5, 7, 12), 2 A (all
others)
Housing StyleFemale Part NumberMale Part NumberFeaturesPinout
RSF ..1/2-14NPT
Typical panel cutout 22.5 mm
RKF ...1/2-14NPT
Typical panel cutout 22.5 mm
RSF ..3/4-14NPT
Typical panel cutout 22.5 mm
RKF ..3/4-14NPT
RKF 190-*M/14.5/NPTRSF 190-*M/14.5/NPT
RKF 190-*M/14.75/NPT RSF 190-*M/14.75/NPT
3x18, 16x22 AWG,
105 °C, 1/2-14 NPT
threads
3x18, 16x22 AWG
105 °C, 3/4-14 NPT
threads
1. VT
2. RD
3. GY
4. RD/BU
5. BU
6. GN
7. BN
8. WH/GN
9. WH/YE
10. WH/GY
11. BK
12. GN/YE
13. YE/BN
14. BN/GN
15. WH
16. YE
17. PK
18. GY/BN
19. GY/PK
Female
We reserve the right to make technical alterations without prior notice.
Male
Typical panel cutout 22.5 mm
Standard lead length is 0.3 meters. Consult factory for other lengths.
**
Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing.
For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
y IEC IP68 Protectiony 300 V, 4 A (pins 5, 7, 12), 2 A (all
others)
Housing StyleFemale Part NumberMale Part NumberFeaturesPinout
RKF ..PG16
Typical panel cutout 22.5 mm
3x18, 16x22 AWG,
RKF 190-*M/PG 16RSF 190-*M/PG 16
RSF ..PG16
Typical panel cutout 22.5 mm
RKF ...M20
We reserve the right to make technical alterations without prior notice.
Typical panel cutout 22.5 mm
RKF 190-*M/M20RSF 190-*M/M20
RSF ..M20
105 °C, PG 16
threads
3x18, 16x22 AWG,
105 °C, M20 threads
1. VT
2. RD
3. GY
4. RD/BU
5. BU
6. GN
7. BN
8. WH/GN
9. WH/YE
10. WH/GY
11. BK
12. GN/YE
13. YE/BN
14. BN/GN
15. WH
16. YE
17. PK
18. GY/BN
19. GY/PK
Female
Male
Receptacles
Typical panel cutout 22.5 mm
Standard lead length is 0.3 meters. Consult factory for other lengths.
**
Standard housing material is nickel plated brass.. “RSF ..”; “RSFV ..” indicates stainless steel housing, and “RSFK ..” indicates nylon housing.
For locknuts to be included, add “W/LN” to the end of the part number. To specify PVC jacketed cable, add “/S717” to the end of the part number.
B2007 F41
7/8” minifast® Connectivity Products
2 and 3-Wire Receptacles, Back Panel Mount
y NEMA 1, 3, 4, 6Py IEC IP68 Protectiony 600 V
Housing StyleFemale Part NumberMale Part NumberFeaturesPinout
RKFP ..
RKFP Cutout
Recommended maximum panel thickness is 6.4 mm
RSFP ..
RKFP 20-*MRSFP 20-*M
RKFP 26-*MRSFP 26-*M
RKFP 30-*MRSFP 30-*M
RKFP 31-*MRSFP 31-*M
RKFP 311-*MRSFP 311-*M
RKFP 35-*MRSFP 35-*M
2x18 AWG, 105 °C,
9 A, M30x1.5 threads,
standard duty
2x16 AWG, 105 °C,
10 A, M30x1.5
threads, heavy duty
3x18 AWG, 105 °C,
9 A, M30x1.5 threads,
standard duty
3x18 AWG, 105 °C,
9 A, M30x1.5 threads,
standard duty
3x18 AWG, 105 °C,
9 A, M30x1.5 threads,
automotive color
code
3x16 AWG, 105 °C,
10 A, automotive
color code, M30x1.5
Threads
1. BN
2. BU
1. WH
2. BK
1. GN/YE
2. BN
3. BU
1. BK
2. BN
3. BU
1. GN
2. RD/BK
3. RD/WH
Female/Male
We reserve the right to make technical alterations without prior notice.
Female
Male
RSFP Cutout
Recommended maximum panel thickness is 6.4 mm
RKFP 36-*MRSFP 36-*M
Standard lead length is 0.3 meters. Consult factory for other lengths.
**
Standard housing material is nickel plated brass.. “RSFP ..”; “RSFPV ..” indicates stainless steel housing.
To specify PVC jacketed cable, add “/S717” to the end of the part number.
3x16 AWG, 105 °C,
10 A, M30x1.5
threads, heavy duty
Housing StyleFemale Part NumberMale Part NumberFeaturesPinout
RKFP ..
RKFP Cutout
Recommended maximum panel thickness is 6.4 mm
RSFP ..
We reserve the right to make technical alterations without prior notice.
RKFP 40-*MRSFP 40-*M
RKFP 46-*MRSFP 46-*M
4x18 AWG, 105 °C,
9 A, M30x1.5 Threads,
Standard Duty
4x16 AWG, 105 °C,
10 A, M30x1.5
Threads, Heavy Duty
1. BN
2. WH
3. BU
4. BK
1. BK
2. WH
3. RD
4. GN
Female
Receptacles
Male
Female
Male
RSFP Cutout
Recommended maximum panel thickness is 6.4 mm
Standard lead length is 0.3 meters. Consult factory for other lengths.
**
Standard housing material is nickel plated brass.. “RSFP ..”; “RSFPV ..” indicates stainless steel housing.
To specify PVC jacketed cable, add “/S717” to the end of the part number.
B2007 F43
7/8” minifast® Connectivity Products
5 and 6-Wire Receptacles, Back Panel Mount
y NEMA 1, 3, 4, 6Py IEC IP68 Protectiony 600 V
Housing StyleFemale Part NumberMale Part NumberFeaturesPinout
RKFP 50-*MRSFP 50-*M
RKFP ..
RKFP 511-*MRSFP 511-*M
RKFP Cutout
Recommended maximum panel thickness is 6.4 mm
RKFP 55-*MRSFP 55-*M
5x18 AWG, 105 °C,
9 A, M30x1.5 Threads,
Standard Duty
5x18 AWG, 105 °C,
9 A, Automotive
Color Code, M30x1.5
Threads
5x16 AWG, 105 °C,
10 A, Automotive
Color Code, M30x1.5
Threads
1. BK
2. BU
3. GN/YE
4. BN
5. WH
1. RD/WH
2. RD/BU
3. GN
4. RD/OG
5. RD/BK
Female
We reserve the right to make technical alterations without prior notice.
Male
RKFP 56-*MRSFP 56-*M
RSFP ..
RKFP 61-*MRSFP 61-*M
RKFP 66-*MRSFP 66-*M
RSFP Cutout
Recommended maximum panel thickness is 6.4 mm
RKFP 68-*MRSFP 68-*M
Standard lead length is 0.3 meters. Consult factory for other lengths.
**
Standard housing material is nickel plated brass.. “RSFP ..”; “RSFPV ..” indicates stainless steel housing.
To specify PVC jacketed cable, add “/S717” to the end of the part number.
5x16 AWG, 105 °C,
10 A, M30x1.5
Threads, Heavy Duty
6x18 AWG, 105 °C,
8 A, M30x1.5 Threads,
Standard Duty