Turck M23 multifast, M27 multifast Catalog Page

M23 and M27 multifast® Connectivity
Receptacle Selection Guide
Mounting Style Image Panel Thread Types Page
M23 H20
Front Mount
M27 H30
Rear Mount
Cordsets
M23 H25
B2007 H19
M23 multifast® Connectivity
12-Pin Receptacles, Front Mount
y For use with Junction Box Home
Run Cables
y IEC IP67 Protection y 300 V, 6 A
Connector Style Female Part Number Male Part Number Features Pinout
CS(K)F..
Typical panel cutout is 20.4 x 19 x 20.4 mm
CKF 12-7-* CSF 12-7-*
CKF 12-9-* CKF 12-9-*
CKF 12-11-* CSF 12-11-*
Nickel plated brass, 7x18 AWG, 105 °C, 4-port, 1 signal per port
Nickel plated brass, 9x18 AWG, 105 °C, 6-port, 1 signal per port
Nickel plated brass, 11x18 AWG, 105 °C, 8-port, 1 signal per port
1. BN
3. BU
4. WH
6. GN
1. BN
3. BU
4. WH
6. GN
7. YE
1. BN
3. BU
4. WH
5. GN
6. YE
7. GY
7. YE
8. GY
12. GN/YE
8. GY
9. PK
10. RD
12. GN/YE
8. PK
9. RD
10. BK
11. VT
12. GN/YE
Female
CS(K)FL..
Typical panel cutout is 20.4 x 19 x 20.4 mm
* Length in meters. Standard lead length is 1 meter. Consult factory for other lengths.
“CSFL ..” indicates long mounting threads; “CSFLV ..” indicates stainless steel housing with long threads. To specify PVC jacketed cable, add “/S717” to the end of the part number.
CKF 12-12-* CSF 12-12-*
CKF 12-12-*/S817 CSF 12-12-*/S817
Nickel plated brass, 12x18 AWG, 105 °C, 8-port, 1 signal per port
Nickel plated brass, 12x18 AWG, 105 °C, 8-port, 1 signal per port
1. BN
2. OG
3. BU
4. WH
5. GN
6. YE
1. BN
2. BU
3. WH
4. GN/YE
5. OG
6. YE
7. GY
8. PK
9. RD
10. BK
11. VT
12. GN/YE
7. GY
8. PK
9. RD
10. BN/WH
11. BU/WH
12. GN/WH
Male
H20 B2007 www.turck.com 1-800-544-7769 Fax: (763) 553-0708 Turck Minneapolis, MN 55441 B2007 H21
M23 multifast® Connectivity
19-Pin Receptacles, Front Mount
y For use with Junction Box Home
Run Cables
y IEC IP67 Protection y 150 V, 9 A (pins 6, 12, 19), all
others 2 A
Connector Style Female Part Number Male Part Number Features Pinout
CKF 19-11-* CSF 19-11-*
CS(K)F..
Typical panel cutout is 20.4 x 19 x 20.4 mm
CKF 19-15-* CSF 19-15-*
Nickel plated brass, 3x18, 8x22 AWG, 105 °C, 4-port, 2 signals per port
Nickel plated brass, 3x18, 12x22 AWG, 105 °C, 6-port, 2 signals per port
3. GY
4. RD/BU
5. GN
6. BU
7. GY/PK
8. WH/GN
12. GN/YE
14. BN/GN
15. WH
16. YE
19. BN
2. RD
3. GY
4. RD/BU
5. GN
6. BU
7. GY/PK
8. WH/GN
9. WH/YE
12. GN/YE
13. YE/BN
14. BN/GN
15. WH
16. YE
17. PK
19. BN
Female
Receptacles
CS(K)FL..
CKF 19-19-* CSF 19-19-*
Typical panel cutout is 20.4 x 19 x 20.4 mm
* Length in meters. Standard lead length is 1 meter. Consult factory for other lengths.
“CSFL ..” indicates long mounting threads; “CSFLV ..” indicates stainless steel housing with long threads. To specify PVC jacketed cable, add “/S717” to the end of the part number.
Nickel plated brass, 3x18, 16x22 AWG, 105 °C, 8-port, 2 signals per port
1. VT
2. RD
3. GY
4. RD/BU
5. GN
6. BU
7. GY/PK
8. WH/GN
9. WH/YE
10. WH/GY
11. BK
12. GN/YE
13. YE/BN
14. BN/GN
15. WH
16. YE
17. PK
18. GY/BN
19. BN
Male
B2007 H21
M23 multifast® Connectivity
12 and 16-Pin Receptacles, Front Mount
y For use with Junction Box Home
Run Cables
y IEC IP67 Protection
Connector Style Female Part Number Male Part Number Features Pinout
CK(A)(B)F.. CS(A)(B)F..
Typical panel cutout is 20.4 x 19 x 20.4 mm
CKAF 16-10-* CSAF 16-10-*
CKAF 16-12-* CSAF 16-12-*
CKAF 16-14-* CSAF 16-14-*
Nickel plated brass, 10x18 AWG, 105 °C, 150 V, 6 A, 4-port, Isolated Power Supply
Nickel plated brass, 12x18 AWG, 105 °C, 150 V, 6 A, 6-port, Isolated Power Supply
Nickel plated brass, 14x18 AWG, 105 °C, 150 V, 6 A, 8-port, Isolated Power Supply
1. BN
3. BU
4. WH
5. GN/YE
6. OG
1. BN
3. BU
4. WH
5. GN/YE
6. OG
7. YE
1. BN
3. BU
4. WH
5. GN/YE
6. OG
7. YE
8. GY
7. YE
8. GY
11. BN/WH
13. BU/WH
15. GN/WH
8. GY
9. PK
10. RD
11. BN/WH
13. BU/WH
15. GN/WH
9. PK
10. RD
11. BN/WH
12. BK
13. BU/WH
14. VT
15. GN/WH
Female
Male
Female
CK(A)(B)FL.. CS(A)(B)FL..
Typical panel cutout is 20.4 x 19 x 20.4 mm
* Length in meters. Standard lead length is 1 meter. Consult factory for other lengths.
“CSA(B)FL ..” indicates long mounting threads; “CSA(B)FLV ..” indicates stainless steel housing with long threads. To specify PVC jacketed cable, add “/S717” to the end of the part number.
CKBF 12-7-* CSBF 12-7-*
CKBF 12-11-* CSBF 12-11-*
Nickel plated brass, 7x18 AWG, 105 °C, 300 V, 6 A, 4-port, with LEDs
Nickel plated brass, 11x18 AWG, 105 °C, 300 V, 6 A, 8-port, with LEDs
1. WH/BK
2. BK
3. WH
4. RD
1. OG
2. BU
3. WH/BK
4. RD/BK
5. GN/BK
6. OG/BK
5. OG
6. BU
7. GN
Male
7. BU/BK
9. GN
10. RD
11. WH
12. BK
H22 B2007 www.turck.com 1-800-544-7769 Fax: (763) 553-0708 Turck Minneapolis, MN 55441 B2007 H23
M23 multifast® Connectivity
12-Pin Receptacles, Front Mount
y For use with Junction Box Home
Run Cables
y IEC IP67 Protection y 300 V, 6 A
Connector Style Female Part Number Male Part Number Features Pinout
CK(C)(N)F.. CS(C)(N)F..
Typical panel cutout is 20.4 x 19 x 20.4 mm
CK(C)(N)FL.. CS(C)(N)FL..
CKCF 12-7-* CSCF 12-7-*
CKCF 12-11-* CSCF 12-11-*
Nickel plated brass, 7x18 AWG, 105 °C, 4-port, 1 signal per port, 4MB12Z-4-*
Nickel plated brass, 11x18 AWG, 105 °C, 8-port, 1 signal per port, 8MB12Z-4-*
1. WH
2. GN
3. YE
4. GY
10. BU
11. BN
12. GN/YE
1. WH
2. GN
3. YE
4. GY
5. PK
6. RD
7. BK
8. VT
10. BU
11. BN
12. GN/YE
Female
Receptacles
Male
Typical panel cutout is 20.4 x 19 x 20.4 mm
* Length in meters. Standard lead length is 1 meter. Consult factory for other lengths.
“CSC(N or R)FL ..” indicates long mounting threads; “CSC(N or R)FLV ..” indicates stainless steel housing with long threads. To specify PVC jacketed cable, add “/S717” to the end of the part number.
CKNF 12-9-* CSNF 12-9-*
Nickel plated brass, 9x18 AWG, 105 °C, 4-port, 1 isolated circuit per port or 2 circuits per port with common positive
1. BN
2. WH
3. BK
4. GN
5. RD
6. OG
7. BU
8. YE
9. VT
B2007 H23
M23 multifast® Connectivity
12 and 16-Pin Receptacles, Front Mount
y For use with Junction Box Home
Run Cables
y IEC IP67 Protection
Connector Style Female Part Number Male Part Number Features Pinout
CK(C)(N)(R)F.. CS(C)(N)(R)F..
Typical panel cutout is 20.4 x 19 x 20.4 mm
CKNF 16-16-* CSNF 16-16-*
CKRF 12-6-* CSRF 12-6-*
Nickel plated brass, 16x22 AWG, 105 °C, 300 V, 3 A, 4-port, 2 isolated circuits per port
Nickel plated brass, 6x18 AWG, 105 °C, 300 V, 6 A, 4-port, No LEDs
1. WH
2. BK
3. GN
4. RD
5. OG
6. BU
7. BN
8. YE
9. VT
10. GY
11. PK
12. Tn
13. WH/BK
14. WH/GN
15. WH/RD
16. WH/BU
1. OG
2. BU
4. BK
5. WH
6. RD
7. GN
Female
Male
Female
Nickel plated brass, 8x18
CK(C)(N)(R)FL..
CKRF 12-8-* CSRF 12-8-*
CS(C)(N)(R)FL..
Typical panel cutout is 20.4 x 19 x 20.4 mm
CKRF 12-10-* CSRF 12-10-*
* Length in meters. Standard lead length is 1 meter. Consult factory for other lengths.
“CSC(N or R)FL ..” indicates long mounting threads; “CSC(N or R)FLV ..” indicates stainless steel housing with long threads. To specify PVC jacketed cable, add “/S717” to the end of the part number.
AWG, 105 °C, 300 V, 6 A, 6-port, No LEDs
Nickel plated brass, 10x18 AWG, 105 °C, 300 V, 6 A, 8-port, No LEDs
1. OG
2. BU
3. YE
4. BK
5. WH
6. RD
7. GN
8. BN
1. VT
2. BU
3. GY
4. BK
5. WH
6. RD
7. GN
8. YE
9. OG
10. BN
Male
H24 B2007 www.turck.com 1-800-544-7769 Fax: (763) 553-0708 Turck Minneapolis, MN 55441 B2007 H25
M23 multifast® Connectivity
12-Pin Receptacles, Rear Mount
y For use with Junction Box Home
Run Cables
y IEC IP67 Protection y 300 V, 6 A
Connector Style Female Part Number Male Part Number Features Pinout
CKFD 12-7-* CSFD 12-7-*
CKFD 12-9-* CSFD 12-9-*
CKFD 12-11-* CSFD 12-11-*
CS(K)FD..
Typical panel cutout is 25.4 x 24.3 x 25.4 mm
CKFD 12-12-* CSFD 12-12-*
CKFD 12-12-*/S817 CSFD 12-12-*/S817
* Length in meters. Standard lead length is 1 meter. Consult factory for other lengths.
To specify PVC jacketed cable, add “/S717” to the end of the part number.
Nickel plated brass, 7x18 AWG, 105 °C, 4-port, 1 signal per port
Nickel plated brass, 9x18 AWG, 105 °C, 6-port, 1 signal per port
Nickel plated brass, 11x18 AWG, 105 °C, 8-port, 1 signal per port
Nickel plated brass, 12x18 AWG, 105 °C, 8-port, 1 signal per port
Nickel plated brass, 12x18 AWG, 105 °C, 8-port, 1 signal per port
1. BN
3. BU
4. WH
6. GN
7. YE
8. GY
12. GN/YE
1. BN
3. BU
4. WH
6. GN
7. YE
8. GY
9. PK
10. RD
12. GN/YE
1. BN
3. BU
4. WH
5. GN
6. YE
7. GY
8. PK
9. RD
10. BK
11. VT
12. GN/YE
1. BN
2. OG
3. BU
4. WH
5. GN
6. YE
7. GY
8. PK
9. RD
10. BK
11. VT
12. GN/YE
1. BN
2. BU
3. WH
4. GN/YE
5. OG
6. YE
7. GY
8. PK
9. RD
10. BN/WH
11. BU/WH
12. GN/WH
Female
Receptacles
Male
B2007 H25
M23 multifast® Connectivity
19-Pin Receptacles, Rear Mount
y For use with Junction Box Home
Run Cables
y IEC IP67 Protection y 150 V, 9 A (pins 6, 12, 19), All
others 2 A
Connector Style Female Part Number Male Part Number Features Pinout
CKFD 19-11-* CSFD 19-11-*
CKFD 19-15-* CSFD 19-15-*
CS(K)FD..
Typical panel cutout is 25.4 x 24.3 x 25.4 mm
CKFD 19-19-* CSFD 19-19-*
* Length in meters. Standard lead length is 1 meter. Consult factory for other lengths.
To specify PVC jacketed cable, add “/S717” to the end of the part number.
Nickel plated brass, 3x18, 8x22 AWG, 105 °C, 4-port, 2 signals per port
Nickel plated brass, 3x18, 12x22 AWG, 105 °C, 6-port, 2 signals per port
Nickel plated brass, 3x18, 16x22 AWG, 105 °C, 8-port, 2 signals per port
3. GY
4. RD/BU
5. GN
6. BU
7. GY/PK
8. WH/GN
12. GN/YE
14. BN/GN
15. WH
16. YE
19. BN
2. RD
3. GY
4. RD/BU
5. GN
6. BU
7. GY/PK
8. WH/GN
9. WH/YE
12. GN/YE
13. YE/BN
14. BN/GN
15. WH
16. YE
17. PK
19. BN
1. VT
2. RD
3. GY
4. RD/BU
5. GN
6. BU
7. GY/PK
8. WH/GN
9. WH/YE
10. WH/GY
11. BK
12. GN/YE
13. YE/BN
14. BN/GN
15. WH
16. YE
17. PK
18. GY/BN
19. BN
Female
Male
H26 B2007 www.turck.com 1-800-544-7769 Fax: (763) 553-0708 Turck Minneapolis, MN 55441 B2007 H27
M23 multifast® Connectivity
16-Pin Receptacles, Rear Mount
y For use with Junction Box Home
Run Cables
y IEC IP67 Protection y 150 V, 6 A
Connector Style Female Part Number Male Part Number Features Pinout
CKAFD 16-10-* CSAFD 16-10-*
CS(K)FD..
CKAFD 16-12-* CSAFD 16-12-*
Typical panel cutout is 25.4 x 24.3 x 25.4 mm
* Length in meters. Standard lead length is 1 meter. Consult factory for other lengths.
To specify PVC jacketed cable, add “/S717” to the end of the part number.
CKAFD 16-14-* CSAFD 16-14-*
Nickel plated brass, 10x18 AWG, 105 °C, 4-port, Isolated Power Supply
Nickel plated brass 12x18 AWG, 105 °C, 6-port, Isolated Power Supply
Nickel plated brass, 14x18 AWG, 105 °C, 8-port, Isolated Power Supply
1. BN
3. BU
4. WH
5. GN/YE
6. OG
7. YE
8. GY
11. BN/WH
13. BU/WH
15. GN/WH
1. BN
3. BU
4. WH
5. GN/YE
6. OG
7. YE
8. GY
9. PK
10. RD
11. BN/WH
13. BU/WH
15. GN/WH
1. BN
3. BU
4. WH
5. GN/YE
6. OG
7. YE
8. GY
9. PK
10. RD
11. BN/WH
12. BK
13. BU/WH
14. VT
15. GN/WH
Female
Receptacles
Male
B2007 H27
M23 multifast® Connectivity
12-Pin Receptacles, Rear Mount
y For use with Junction Box Home
Run Cables
y IEC IP67 Protection y 300 V, 6 A
Connector Style Female Part Number Male Part Number Features Pinout
CKBFD 12-7-* CSBFD 12-7-*
CKBFD 12-11-* CSBFD 12-11-*
Nickel plated brass, 7x18 AWG, 105 °C, 4-port, with LEDs
Nickel plated brass, 11x18 AWG, 105 °C, 8-port, with LEDs
1. WH/BK
2. BK
3. WH
4. RD
5. OG
6. BU
7. GN
1. OG
2. BU
3. WH/BK
4. RD/BK
5. GN/BK
6. OG/BK
7. BU/BK
9. GN
10. RD
11. WH
12. BK
Female
CS(K)FD..
Typical panel cutout is 25.4 x 24.3 x 25.4 mm
CKCFD 12-7-* CSCFD 12-7-*
CKCFD 12-9-* CSCFD 12-9-*
CKCFD 12-11-* CSCFD 12-11-*
Nickel plated brass, 7x18 AWG, 105 °C, 4-port, 1 signal per port, 4MB12Z-4-*
Nickel plated brass, 9x18 AWG, 105 °C, 4-port, 1 signal per port, 6MB12Z-4-*
Nickel plated brass, 11x18 AWG, 105 °C, 8-port, 1 signal per port, 8MB12Z-4-*
1. WH
2. GN
3. YE
4. GY
10. BU
11. BN
12. GN/YE
1. WH
2. GN
3. YE
4. GY
5. PK
6. RD
10. BU
11. BN
12. GN/YE
1. WH
2. GN
3. YE
4. GY
5. PK
6. RD
7. BK
8. VT
10. BU
11. BN
12. GN/YE
Male
* Length in meters. Standard lead length is 1 meter. Consult factory for other lengths.
To specify PVC jacketed cable, add “/S717” to the end of the part number.
H28 B2007 www.turck.com 1-800-544-7769 Fax: (763) 553-0708 Turck Minneapolis, MN 55441 B2007 H29
M23 multifast® Connectivity
12 and 16-Pin Receptacles, Rear Mount
y For use with Junction Box Home
Run Cables
y IEC IP67 Protection
Connector Style Female Part Number Male Part Number Features Pinout
CKNFD 12-9-* CSNFD 12-9-*
Nickel plated brass, 9x22 AWG, 105 °C, 300 V, 6 A, 4-port, 1 Isolated Circuits Per Port, 2 Circuits Per Port, with Common Positive
1. BN
2. WH
3. BK
4. GN
5. RD
6. OG
7. BU
8. YE
9. VT
Female
Male
CS(K)FD..
Typical panel cutout is 25.4 x 24.3 x 25.4 mm
CKNFD 16-16-* CSNFD 16-16-*
CKRFD 12-6-* CSRFD 12-6-*
CKRFD 12-8-* CSRFD 12-8-*
Nickel plated brass, 16x22 AWG, 105 °C, 300 V, 3 A, 4-port, 2 Isolated Circuits Per Port
Nickel plated brass, 6x18 AWG, 105 °C, 300 V, 6 A, 4-port, No LEDs
Nickel plated brass, 8x18 AWG, 105 °C, 300 V, 6 A, 6-port, No LEDs
1. WH
2. BK
3. GN
4. RD
5. OG
6. BU
7. BN
8. YE
9. VT
10. GY
11. PK
12. Tn
13. WH/BK
14. WH/GN
15. WH/RD
16. WH/BU
1. OG
2. BU
4. BK
5. WH
6. RD
7. GN
1. OG
5. WH
2. BU
6. RD
3. YE
7. GN
4. BK
8. BN
Female
Receptacles
Male
Female
1. VT
2. BU
3. GY
Nickel plated brass,
CKRFD 12-10-* CSRFD 12-10-*
B2007 H29
10x18 AWG, 105 °C, 300 V, 6 A, 8-port, No LEDs
4. BK
5. WH
6. RD
7. GN
8. YE
9. OG
10. BN
Male
M27 multifast® Connectivity
26 and 28-Pin Receptacles, Front Mount
y For use with Junction Box Home
Run Cables
y IEC IP67 Protection y 150 V, 3 A
Connector Style Female Part Number Male Part Number Features Pinout
DKF 26-25-* DSF 26-25-*
DS(K)F..
Typical panel cutout is 28.3 mm
DKF 28-27-* DSF 28-27-*
* Length in meters. Standard lead length is 1 meter. Consult factory for other lengths.
To specify PVC jacketed cable, add “/S717” to the end of the part number.
Nickel-plated brass, 25x22 AWG, 105 °C, 25-wire applications
Nickel-plated brass, 27x22 AWG, 105 °C, 27-wire applications
1. BN
2. WH/GY
3. BU/GY
4. BN/GY
5. BK/YE
6. WH/YE
7. BU/YE
8. BN/YE
9. BK/RD
10. WH/RD
11. BU/RD
12. BN/RD
13. BK
14. WH
15. BU
16. BK/GY
17. BN/OG
18. WH/OG
19. BK/OG
20. BK/GN
21. WH/GN
22. BU/GN
23. BN/GN
24. BU/OG
25. GN/YE
26. N/C
1. BN
2. WH/GY
3. BU/GY
4. BN/GY
5. BK/YE
6. WH/YE
7. BU/YE
8. BN/YE
9. BK/RD
10. WH/RD
11. BU/RD
12. BN/RD
13. BK
14. WH
15. BU
16. BK/GY
17. BN/OG
18. WH/OG
19. BK/OG
20. BK/GN
21. WH/GN
22. BU/GN
23. BN/GN
24. BU/OG
25. GN/YE
26. GY
27. OG
28. N/C
Female
Male
Female
Male
Loading...