Magnetic Field Sensor
for pneumatic cylinders
BIM-UNT-AN6X2-V1131
■ For T-groove cylinders without mount-
ing accessories
■ Optional accessories for mounting on
other cylindrical housings.
■ One-hand mounting possible
■ Fine adjustment tool and stopper direct-
ly mountable on the sensor
■ Stable mounting
■ Magneto-resistive sensor
■ DC 3-wire, 10…30 VDC
■ NO contact, NPN output
■ Male M8 x 1
Type designation BIM-UNT-AN6X2-V1131
Ident-No. 4685753
Ident. no. 4685753
Pass speed
Repeatability
Temperature drift
Hysteresis
Ambient temperature -25…+70 °C
Operating voltage 10…30 VDC
Residual ripple
DC rated operational current
No-load current I
Residual current
Isolation test voltage
Short-circuit protection yes/ Cyclic
Voltage drop at I
Wire breakage/Reverse polarity protection yes/ Complete
Output function 3-wire, NO contact, NPN
Switching frequency 1 kHz
Design Rectangular,UNT
Dimensions 30 x 5 x 22 mm
Housing material Plastic, PP
Active area material Plastic, PP
Tightening torque fixing screw 0.4 Nm
Electrical connection Connectors, M8 × 1
Vibration resistance 55 Hz (1 mm)
Shock resistance 30 g (11 ms)
Protection class IP67
MTTF 2283 years acc. to SN 29500 (Ed. 99) 40 °C
Packaging unit 1
Mounting on the following profiles .
Cylindrical design
0
e
ð 10 m/s
ð ± 0.1 mm
ð 0.1 mm
ð 1 mm
ð 10 % U
ss
ð 150 mA
ð 15 mA
ð 0.1 mA
ð 0.5 kV
ð 1.8 V
E N K F
Wiring Diagram
Functional principle
Magnetic field sensors are activated by magnetic fields and are used, in particular, for the
detection of the piston position in pneumatic
cylinders. As magnetic fields can permeate
non-magnetizable metals, they detect a permanent magnet attached to the piston through
the aluminium cylinder wall.
Power-on indication LED,Green
Switching state LED,Yellow
Edition • 2018-07-11T22:30:11+02:00
1 / 5 TURCK Inc.

Magnetic Field Sensor
for pneumatic cylinders
BIM-UNT-AN6X2-V1131
Mounting instructions/Description Mounting instructions
Insert the sensor laterally in the groove with the tip first.
Once the correct postion is attained click the sensor in
the groove. Finally, screw the sensor tight. Mount the
sensors as follows using the patented wing screw: The
wing screw features a left-hand female thread. Two
small plastic lips keep the screw in position, ready-to-
install. Turn the screw clockwise. The screw moves out
of the thread and hits the upper grooves with the wings.
The sensor is thus pressed down and locked. Use a
standard screw driver or a 1.5 mm Allen key to fasten
the screw with a quarter turn. A fixing torque of 0.4 Nm
is sufficient for safe mounting without damaging the
cylinder. Mounting accessories for other cylinder sizes
have to be ordered separately.
Edition • 2018-07-11T22:30:11+02:00