Turck BIM-UNR-AP6X1M Data Sheet

Magnetic Field Sensor for pneumatic cylinders BIM-UNR-AP6X 1M
Type designation BIM-UNR-AP6X 1M
Ident-No. 4685901
For C-groove cylinders without mount-
ing accessories
Optional accessories for mounting on
other cylindrical housings.
One-hand mounting possible
Stable mounting
Magneto-resistive sensor
DC 3-wire, 11…30 VDC
NO contact, PNP output
Cable connection
Wiring Diagram
Pass speed
Repeatability Temperature drift Hysteresis Ambient temperature -25…+70 °C
Operating voltage 11…30 VDC Residual ripple DC rated operational current No-load current I Residual current Isolation test voltage Short-circuit protection yes/ Cyclic Voltage drop at I Wire breakage/Reverse polarity protection yes/ Complete Output function 3-wire, NO contact, PNP Switching frequency 0.3 kHz
Design Rectangular,UNR Dimensions 18 x 2.9 x 4.6 mm Housing material Plastic, PP Active area material Plastic, PP Tightening torque fixing screw 0.2 Nm Electrical connection Cable Cable quality 2mm, Gray, Lif9Y-11Y, PUR, 2 Cable cross section
Litz wire 40x0.05mm Vibration resistance 55 Hz (1 mm) Shock resistance 30 g (11 ms) Protection class IP67 MTTF 2283 years acc. to SN 29500 (Ed. 99) 40 °C Packaging unit 1 Mounting on the following profiles . Cylindrical design
0
e
ð 10 % U
ss
ð 100 mA ð 15 mA ð 0.1 mA ð 0.5 kV
ð 1.8 V
3 x 0.08 mm
M
2
Functional principle
Magnetic field sensors are activated by mag­netic fields and are used, in particular, for the detection of the piston position in pneumatic cylinders. As magnetic fields can permeate non-magnetizable metals, they detect a per­manent magnet attached to the piston through the aluminium cylinder wall.
Derating Curve
Switching state LED,Yellow
Included in delivery cable clip
Edition • 2018-03-28T18:38:57+02:00
1 / 2 TURCK Inc.
Magnetic Field Sensor for pneumatic cylinders BIM-UNR-AP6X 1M
Mounting instructions/Description Mounting instructions
The sensor is mounted in the groove from above.
Mount the sensors as follows using the patented wing
screw: The wing screw features a left-hand female
thread. Two small plastic lips keep the screw in posi-
tion, ready-to-install. Turn the screw clockwise. The
screw moves out of the thread and hits the upper
grooves with the wings. The sensor is thus pressed
down and locked. Use a 1.5 mm Allen key to fasten
the screw with a quarter turn. A fixing torque of 0.2 Nm
is sufficient for safe mounting without damaging the
cylinder. Cable clips are included in the scope of deliv-
ery. They enable smooth cable routing in the groove.
Mounting accessories for other cylinder sizes have to
be ordered separately.
Edition • 2018-03-28T18:38:57+02:00
2 / 2 TURCK Inc.