Magnetic Field Sensor
for pneumatic cylinders
BIM-QST-Y1X
Type designation BIM-QST-Y1X
Ident-No. 1058000
■ ATEX category II 2 G, Ex zone 1
■ ATEX category II 1 D, Ex zone 20
■ SIL2 (Low Demand Mode) acc. to IEC
61508, PL c acc. to ISO 13849-1 at HFT0
■ SIL3 (All Demand Mode) acc. to IEC
61508, PL e acc. to ISO 13849-1 with redundant configuration HFT1
■ Rectangular, height 12 mm
■ Front active face
■ Plastic, PA12-GF30
■ Magnetic-inductive sensor
■ DC 2-wire, nom. 8.2 VDC
■ Output acc. to DIN EN 60947-5-6 (NA-
MUR)
■ Cable connection
Pass speed
Repeatability
Temperature drift
Hysteresis
Ambient temperature -25…+70 °C
Output function 2-wire, NAMUR
Switching frequency 1 kHz
Voltage Nom. 8.2 VDC
Current consumption non-actuated
Actuated current consumption
Approval acc. to KEMA 02 ATEX 1090X
Design Rectangular,QST
Dimensions 20 x 12 x 12 mm
Housing material Plastic, PA12-GF30
Active area material Plastic, PA12-GF30
Electrical connection Cable
Cable quality 4mm, Blue, Lif9YYW, PVC, 2
Cable cross section
Vibration resistance 55 Hz (1 mm)
Shock resistance 30 g (11 ms)
Protection class IP67
MTTF 6198 years acc. to SN 29500 (Ed. 99) 40 °C
Packaging unit 1
Mounting on the following profiles .
Cylindrical design
ð 10 m/s
ð ± 0.1 mm
ð 0.1 mm
ð 1 mm
ð 1.2 mA
ï 2.1 mA
2 x 0.25 mm
G F
2
Wiring Diagram
Functional principle
Magnetic field sensors are activated by magnetic fields and are especially suited for piston position detection in pneumatic cylinders.
Based on the fact that magnetic fields can
permeate non-magnetizable metals, it is possible to detect a permanent magnet attached
to the piston through the aluminium wall of the
cylinder.
Switching state LED,Yellow
Edition • 2018-03-28T21:02:35+02:00
1 / 4 TURCK Inc.

Magnetic Field Sensor
for pneumatic cylinders
BIM-QST-Y1X
Edition • 2018-03-28T21:02:35+02:00
2 / 4 TURCK Inc.

Magnetic Field Sensor
for pneumatic cylinders
BIM-QST-Y1X
Accessories
Type code Ident-No. Description
KLQ-1 Z 6971911
Mounting on G tie-rod cylindes; diameter 32…63 mm, mate-
rial: Anodized aluminium; please order fixing clamp separate-
ly
KLQ-2 Z 6971912
KLQ-1 6971901
KLQ-2 6971902
Mounting on G tie-rod cylindes; diameter 50…125 mm, ma-
terial: Anodized aluminium; please order fixing clamp sepa-
rately
Mounting on G profile cylinders; cylinder diameter 32…50
mm, material: Anodized aluminium; please order fixing clamp
separately
Mounting on G profile cylinders; cylinder diameter 50…100
mm, material: Anodized aluminium; please order fixing clamp
separately
IMX12-DI01-2S-2T-0/
24VDC
Edition • 2018-03-28T21:02:35+02:00
3 / 4 TURCK Inc.
7580020 Isolating switching amplifier, 2-channel; SIL2 acc. to IEC
61508; Ex-proof version; 2 transistor outputs; input Namur
signal; ON/OFF switchable monitoring of wire-break and
short-circuit; toggle between NO/NC mode; signal doubling;
removable screw terminals; 12.5 mm wide; 24 VDC power
supply

Magnetic Field Sensor
for pneumatic cylinders
BIM-QST-Y1X
Operating manual
Intended use
This device fulfills the directive 2014/34/EC and is suited for use in explosion hazardous areas according to EN 60079-0:2012 + A11 and EN
60079-11:2012.
Further it is suited for use in safety-related systems, including SIL2 as per IEC 61508.
In order to ensure correct operation to the intended purpose it is required to observe the national regulations and directives.
For use in explosion hazardous areas conform to classification
II 2 G and II 1 D (Group II, Category 2 G, electrical equipment for gaseous atmospheres and category 1 D, electrical equipment for dust atmospheres).
Marking (see device or technical data sheet)
É II 2 G and Ex ia IIC T6 Gb and É II 1 D Ex ia IIIC T95 °C Da acc. to EN 60079-0, -11
Local admissible ambient temperature
-25…+70 °C
Installation/Commissioning
These devices may only be installed, connected and operated by trained and qualified staff. Qualified staff must have knowledge of protection
classes, directives and regulations concerning electrical equipment designed for use in explosion hazardous areas.
Please verify that the classification and the marking on the device comply with the actual application conditions.
This device is only suited for connection to approved Exi circuits according to EN 60079-0 and EN 60079-11. Please observe the maximum admissible electrical values.
After connection to other circuits the sensor may no longer be used in Exi installations. When interconnected to (associated) electrical equipment, it is required to perform the "Proof of intrinsic safety" (EN60079-14).
Attention! When used in safety systems, all content of the security manual must be observed.
Installation and mounting instructions
Avoid static charging of cables and plastic devices. Please only clean the device with a damp cloth. Do not install the device in a dust flow and
avoid build-up of dust deposits on the device.
If the devices and the cable could be subject to mechanical damage, they must be protected accordingly. They must also be shielded against
strong electro-magnetic fields.
The pin configuration and the electrical specifications can be taken from the device marking or the technical data sheet.
Service/Maintenance
Repairs are not possible. The approval expires if the device is repaired or modified by a person other than the manufacturer. The most important
data from the approval are listed.
Edition • 2018-03-28T21:02:35+02:00