Turck BIM-QST-Y1X Data Sheet

Magnetic Field Sensor for pneumatic cylinders BIM-QST-Y1X
Type designation BIM-QST-Y1X
Ident-No. 1058000
ATEX category II 2 G, Ex zone 1
ATEX category II 1 D, Ex zone 20
SIL2 (Low Demand Mode) acc. to IEC
61508, PL c acc. to ISO 13849-1 at HFT0
SIL3 (All Demand Mode) acc. to IEC
61508, PL e acc. to ISO 13849-1 with re­dundant configuration HFT1
Rectangular, height 12 mm
Front active face
Plastic, PA12-GF30
Magnetic-inductive sensor
DC 2-wire, nom. 8.2 VDC
Output acc. to DIN EN 60947-5-6 (NA-
MUR)
Cable connection
Pass speed
Repeatability Temperature drift Hysteresis Ambient temperature -25…+70 °C
Output function 2-wire, NAMUR Switching frequency 1 kHz Voltage Nom. 8.2 VDC Current consumption non-actuated Actuated current consumption
Approval acc. to KEMA 02 ATEX 1090X
Design Rectangular,QST
Dimensions 20 x 12 x 12 mm Housing material Plastic, PA12-GF30 Active area material Plastic, PA12-GF30 Electrical connection Cable Cable quality 4mm, Blue, Lif9YYW, PVC, 2 Cable cross section
Vibration resistance 55 Hz (1 mm) Shock resistance 30 g (11 ms) Protection class IP67 MTTF 6198 years acc. to SN 29500 (Ed. 99) 40 °C Packaging unit 1 Mounting on the following profiles . Cylindrical design
ð 1.2 mA ï 2.1 mA
2 x 0.25 mm
G F
2
Wiring Diagram
Functional principle
Magnetic field sensors are activated by mag­netic fields and are especially suited for pis­ton position detection in pneumatic cylinders. Based on the fact that magnetic fields can permeate non-magnetizable metals, it is pos­sible to detect a permanent magnet attached to the piston through the aluminium wall of the cylinder.
Switching state LED,Yellow
Edition • 2018-03-28T21:02:35+02:00
1 / 4 TURCK Inc.
Magnetic Field Sensor for pneumatic cylinders BIM-QST-Y1X
Edition • 2018-03-28T21:02:35+02:00
2 / 4 TURCK Inc.
Magnetic Field Sensor for pneumatic cylinders BIM-QST-Y1X
Accessories
Type code Ident-No. Description
KLQ-1 Z 6971911
Mounting on G tie-rod cylindes; diameter 32…63 mm, mate-
rial: Anodized aluminium; please order fixing clamp separate-
ly
KLQ-2 Z 6971912
KLQ-1 6971901
KLQ-2 6971902
Mounting on G tie-rod cylindes; diameter 50…125 mm, ma-
terial: Anodized aluminium; please order fixing clamp sepa-
rately
Mounting on G profile cylinders; cylinder diameter 32…50
mm, material: Anodized aluminium; please order fixing clamp
separately
Mounting on G profile cylinders; cylinder diameter 50…100
mm, material: Anodized aluminium; please order fixing clamp
separately
IMX12-DI01-2S-2T-0/
24VDC
Edition • 2018-03-28T21:02:35+02:00
3 / 4 TURCK Inc.
7580020 Isolating switching amplifier, 2-channel; SIL2 acc. to IEC
61508; Ex-proof version; 2 transistor outputs; input Namur
signal; ON/OFF switchable monitoring of wire-break and
short-circuit; toggle between NO/NC mode; signal doubling;
removable screw terminals; 12.5 mm wide; 24 VDC power
supply
Magnetic Field Sensor for pneumatic cylinders BIM-QST-Y1X
Operating manual
Intended use
This device fulfills the directive 2014/34/EC and is suited for use in explosion hazardous areas according to EN 60079-0:2012 + A11 and EN 60079-11:2012. Further it is suited for use in safety-related systems, including SIL2 as per IEC 61508. In order to ensure correct operation to the intended purpose it is required to observe the national regulations and directives.
For use in explosion hazardous areas conform to classification
II 2 G and II 1 D (Group II, Category 2 G, electrical equipment for gaseous atmospheres and category 1 D, electrical equipment for dust atmo­spheres).
Marking (see device or technical data sheet)
É II 2 G and Ex ia IIC T6 Gb and É II 1 D Ex ia IIIC T95 °C Da acc. to EN 60079-0, -11
Local admissible ambient temperature
-25…+70 °C
Installation/Commissioning
These devices may only be installed, connected and operated by trained and qualified staff. Qualified staff must have knowledge of protection classes, directives and regulations concerning electrical equipment designed for use in explosion hazardous areas. Please verify that the classification and the marking on the device comply with the actual application conditions.
This device is only suited for connection to approved Exi circuits according to EN 60079-0 and EN 60079-11. Please observe the maximum ad­missible electrical values. After connection to other circuits the sensor may no longer be used in Exi installations. When interconnected to (associated) electrical equip­ment, it is required to perform the "Proof of intrinsic safety" (EN60079-14). Attention! When used in safety systems, all content of the security manual must be observed.
Installation and mounting instructions
Avoid static charging of cables and plastic devices. Please only clean the device with a damp cloth. Do not install the device in a dust flow and avoid build-up of dust deposits on the device. If the devices and the cable could be subject to mechanical damage, they must be protected accordingly. They must also be shielded against strong electro-magnetic fields. The pin configuration and the electrical specifications can be taken from the device marking or the technical data sheet.
Service/Maintenance
Repairs are not possible. The approval expires if the device is repaired or modified by a person other than the manufacturer. The most important data from the approval are listed.
Edition • 2018-03-28T21:02:35+02:00
4 / 4 TURCK Inc.
Loading...