BIM-PST-Y1X-0.2-RS4.21T W/KLP80
Magnetic Field Sensor – for pneumatic cylinders
Features
Rectangular, height 16 mm
■
Front active face
■
Plastic, PA12-GF30
■
Magnetic-inductive sensor
■
DC 2-wire, nom. 8.2 VDC
■
Output according DIN EN 60947-5-6
■
(NAMUR)
Pigtail with male end, M12 x 1
■
ATEX category II 2 G, Ex zone 1
■
ATEX category II 1 D, Ex zone 20
■
SIL2 (Low Demand Mode) acc. to IEC 61508,
■
PL c acc. to ISO 13849-1 at HFT0
SIL3 (All Demand Mode) acc. to IEC 61508,
■
PL e acc. to ISO 13849-1 with redundant
Technical data
configuration HFT1
Type
Ident. no. 1057095
Pass speed ≤10m/s
Repeatability ≤ ±0.1mm
Temperature drift ≤0.1mm
Hysteresis ≤1mm
Ambient temperature -25…+70°C
Output function 2-wire, NAMUR
Switching frequency 1kHz
Voltage Nom.8.2VDC
Current consumption non-actuated ≤1.2mA
Actuated current consumption ≥2.1mA
Approval acc. to KEMA 02 ATEX 1090X
Internal capacitance (Ci)/inductance (Li) 150 nF/150 µH
Device marking
Design
Dimensions 23x14x16mm
Housing material Plastic, PA12-GF30
Active area material Plastic, PA12-GF30
Electrical connection Cable with connector,M12 × 1
Cable quality Ø4mm, Blue, LifYY-11Y, PUR, 0.2m
Core cross-section
BIM-PST-Y1X-0.2-RS4.21T W/KLP80
É II 2 G Ex ia IIC T6 Gb / II 1 D Ex ia IIIC
T95 °C Da
(max. Ui = 20 V, Ii = 60 mA, Pi = 130 mW)
Rectangular,PST
2x0.25mm
2
Wiring diagram
Functional principle
Magnetic field sensors are activated by
magnetic fields and are especially suited
for piston position detection in pneumatic
cylinders. Based on the fact that magnetic
fields can permeate non-magnetizable metals,
it is possible to detect a permanent magnet
attached to the piston through the aluminium
wall of the cylinder.
BIM-PST-Y1X-0.2-RS4.21T W/KLP80 | 12/03/2020 06-34 | technical changes reserved
TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com
1|3

Technical data
Vibration resistance 55Hz (1 mm)
Shock resistance 30g (11 ms)
Protection class IP67
MTTF 6198years acc. to SN 29500 (Ed. 99) 40
°C
Mounting on the following profiles
Cylindrical design
E
Switching state LED,Yellow
Included in delivery KLP80
Accessories
IMC-DI-22EX-PNO/24VDC 7560003
2-channel isolating switching amplifier
with M12x1 males, for peripheral use,
IP67, zones 2/22, input circuits II(1)
Ex ia, PNP transistor output NO
KLP 80-VA 69654
Mounting on round cylinders; cylinder
diameter 25…80mm; material: Metal
A2 1.4301 (AISI 304); two tie bolts
(material: Metal CuZn, alternatively
metal A2 1.4301 / AISI 304) cylinder
screw M3 x 20; (DIN 912-A20)
KLP 25 MONTAGESET 69653
Mounting on round cylinders; cylinder
diameter 8…25mm; material: Metal
CuZn; two tie bolts (material: Metal
CuZn), cylinder screw M3 x 20
KLP 200-VA 6965302
Mounting on round cylinders; cylinder
diameter 80…200mm material: Metal
A2 1.4301 (AISI 304); two tie bolts
(material: Metal CuZn, alternatively
metal A2 1.4301 / AISI 304) cylinder
screw M3 x 20; (DIN 912-A20)
TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com
BIM-PST-Y1X-0.2-RS4.21T W/KLP80 | 12/03/2020 06-34 | technical changes reserved
2|3

Operating Instructions
Intended use
This device fulfills the directive 2014/34/EC and is suited for use in explosion hazardous areas according to EN
60079-0:2012 + A11 and EN 60079-11:2012.Further it is suited for use in safety-related systems, including SIL2 as per IEC
61508.In order to ensure correct operation to the intended purpose it is required to observe the national regulations and
directives.
For use in explosion hazardous areas conform to classification
II 2 G and II 1 D (Group II, Category 2 G, electrical equipment for gaseous atmospheres and category 1 D, electrical equipment for
dust atmospheres).
Marking (see device or technical data sheet)
É II 2 G and Ex ia IIC T6 Gb and É II 1 D Ex ia IIIC T95 °C Da acc. to EN 60079-0, -11
Local admissible ambient temperature
-25…+70 °C
Installation/Commissioning
These devices may only be installed, connected and operated by trained and qualified staff. Qualified staff must have
knowledge of protection classes, directives and regulations concerning electrical equipment designed for use in
explosion hazardous areas.Please verify that the classification and the marking on the device comply with the actual
application conditions.
This device is only suited for connection to approved Exi circuits according to EN 60079-0 and EN 60079-11. Please
observe the maximum admissible electrical values.After connection to other circuits the sensor may no longer be
used in Exi installations. When interconnected to (associated) electrical equipment, it is required to perform the "Proof
of intrinsic safety" (EN60079-14).Attention! When used in safety systems, all content of the security manual must be
observed.
Installation and mounting instructions
Avoid static charging of cables and plastic devices. Please only clean the device with a damp cloth. Do not install the
device in a dust flow and avoid build-up of dust deposits on the device.If the devices and the cable could be subject to
mechanical damage, they must be protected accordingly. They must also be shielded against strong electro-magnetic
fields.The pin configuration and the electrical specifications can be taken from the device marking or the technical data
sheet.
Service/Maintenance
Repairs are not possible. The approval expires if the device is repaired or modified by a person other than the
manufacturer. The most important data from the approval are listed.
BIM-PST-Y1X-0.2-RS4.21T W/KLP80 | 12/03/2020 06-34 | technical changes reserved
TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com
3|3