Turck BI5U-EM18M-AD4X Data Sheet

Inductive sensor BI5U-EM18M-AD4X
Type designation BI5U-EM18M-AD4X
Ident-No. 4405205
M18 × 1 threaded barrel
Stainless steel, 1.4301
Factor 1 for all metals
Resistant to magnetic fields
DC 2-wire, 10…65 VDC
NO contact
Cable connection
Wiring Diagram
Rated switching distance Sn 5 mm
Mounting conditions Flush Secured operating distance Repeat accuracy Temperature drift
Hysteresis 3…20 % Ambient temperature -25…+70 °C
Operating voltage 10…65 VDC Residual ripple DC rated operational current Residual current Isolation test voltage Short-circuit protection yes/ Cyclic Voltage drop at I Smallest operating current I Switching frequency 0.01 kHz
Design Threaded barrel,M18 × 1 Dimensions 64 mm Housing material Stainless steel, V2A (1.4301) Active area material Plastic, PBT End cap Plastic, EPTR Max. tightening torque housing nut 25 Nm Electrical connection Cable Cable quality 5.2mm, LifYY, PVC, 2 Cable cross section
Vibration resistance 55 Hz (1 mm) Shock resistance 30 g (11 ms) Protection class IP68 MTTF 874 years acc. to SN 29500 (Ed. 99) 40 °C Packaging unit 1
e
m
ð (0,81 x Sn) mm ð 2 % of full scale ð ± 10 % ð ± 15 %, ð -25 °C v ï +70 °C
ð 10 % U
ss
ð 100 mA ð 0.8 mA ð 0.5 kV
ð 5 V ï 3 mA
2 x 0.34 mm
2
Functional principle
Inductive sensors detect metal objects con­tactless and wear-free. Due to the patented multi-coil system, uprox®+ sensors have dis­tinct advantages compared to conventional sensors. They excel in largest switching dis­tances, maximum flexibility and operational reliability as well as efficient standardization.
Switching state LED,Yellow
Edition • Rev. A • 2018-04-20T17:45:30+02:00
1 / 3 TURCK Inc.
Inductive sensor BI5U-EM18M-AD4X
Distance D 2 x B
Distance W 3 x Sn
Distance T 3 x B
Distance S 1.5 x B
Distance G 6 x Sn
Diameter active area B Ø 18 mm
All flush mountable uprox®+ threaded barrel types are
also recessed mountable. Safe operation is ensured if
the sensor is screwed in by half a turn.
The use of isolating switching amplifiers is possible, be-
cause uprox®+ 2-wire DC sensors operate with 8 VDC
low voltage (limited load current 50mA).
The sensors can be operated with the Turck remote I/
O fieldbus system BL20. If the sensors are combined
with a BL20-4DI-NAMUR slice, events of wire-break or
short-circuit can be detected immediately.
Edition • Rev. A • 2018-04-20T17:45:30+02:00
2 / 3 TURCK Inc.
Loading...
+ 1 hidden pages