Turck BI5-EM18-Y1X-H1141 Data Sheet

Inductive sensor BI5-EM18-Y1X-H1141
ATEX category II 1 G, Ex zone 0
ATEX category II 1 D, Ex zone 20
SIL2 (Low Demand Mode) acc. to IEC
61508, PL c acc. to ISO 13849-1 at HFT0
SIL3 (All Demand Mode) acc. to IEC
61508, PL e acc. to ISO 13849-1 with re­dundant configuration HFT1
Threaded barrel, M18 x 1
Stainless steel, 1.4301
DC 2-wire, nom. 8.2 VDC
Output acc. to DIN EN 60947-5-6 (NA-
MUR)
M12 x 1 male connector
Type designation BI5-EM18-Y1X-H1141
Ident-No. 4015202
Rated switching distance Sn 5 mm Mounting conditions Flush Secured operating distance Correction factors St37 = 1; Al = 0.3; stainless steel = 0.7; Ms = 0.4 Repeat accuracy Temperature drift Hysteresis 1…10 % Ambient temperature -25…+70 °C
Output function 2-wire, NAMUR Switching frequency 1 kHz Voltage Nom. 8.2 VDC Non-actuated current consumption Actuated current consumption
Approval acc. to KEMA 02 ATEX 1090X
Design Threaded barrel,M18 × 1
Dimensions 52 mm Housing material Stainless steel, V2A (1.4301) Active area material Plastic, PA12-GF30 Max. tightening torque housing nut 25 Nm Electrical connection Connectors, M12 × 1 Vibration resistance 55 Hz (1 mm) Shock resistance 30 g (11 ms) MTTF 6198 years acc. to SN 29500 (Ed. 99) 40 °C Packaging unit 1
ð (0,81 x Sn) mm
ð 2 % of full scale ð ± 10 %
ï 2.1 mA ð 1.2 mA
Wiring Diagram
Functional principle
Inductive sensors detect metal objects con­tactless and wear-free. For this, they use a high-frequency electromagnetic AC field that interacts with the target. Inductive sensors generate this field via an RLC circuit with a ferrite coil.
Switching state LED,Yellow
Edition • 2018-07-09T17:45:40+02:00
1 / 4 TURCK Inc.
Inductive sensor BI5-EM18-Y1X-H1141
Distance D 2 x B
Distance W 3 x Sn
Distance T 3 x B
Distance S 1.5 x B
Distance G 6 x Sn
Diameter active area B Ø 18 mm
Edition • 2018-07-09T17:45:40+02:00
2 / 4 TURCK Inc.
Loading...
+ 2 hidden pages