Turck BI5-EM18WDTC-Y1X Data Sheet

Inductive sensor With extended temperature range BI5-EM18WDTC-Y1X
Type designation BI5-EM18WDTC-Y1X
Ident-No. 4012061
Rated switching distance Sn 5 mm Mounting conditions Flush Secured operating distance Correction factors St37 = 1; Al = 0.3; stainless steel = 0.7; Ms = 0.4 Repeat accuracy Temperature drift
Hysteresis 1…10 % Ambient temperature -40…+100 °C
ð (0,81 x Sn) mm
ð 2 % of full scale ð ± 10 % ð ± 20 %, ð -25 °C , ï +70 °C
For explosion hazardous areas see instruction leaflet
ATEX category II 1 G, Ex-zone 0 for tem-
peratures up to +80 °C
ATEX category II 2 G. Ex-zone 1
ATEX category II 1 D, Ex-zone 20 for
temperatures from -25 °C up to +70 °C
SIL2 (Low Demand Mode) acc. to IEC
61508, PL c acc. to ISO 13849-1 at HFT0
SIL3 (All Demand Mode) acc. to IEC
61508, PL e acc. to ISO 13849-1 with re­dundant configuration HTF1
Threaded barrel, M18 x 1
Stainless steel, 1.4404
For temperatures of -40 °C…+100 °C
High protection class IP69K, for harsh
environments
Special double-lip seal
Protection against all common acid and
alkaline cleaning agents
For the food industry
DC 2-wire, nom. 8.2 VDC
Output acc. to DIN EN 60947-5-6 (NA-
MUR)
Terminal chamber
Wiring Diagram
Output function 2-wire, NAMUR
Switching frequency 1 kHz Voltage Nom. 8.2 VDC Non-actuated current consumption Actuated current consumption
Approval acc. to KEMA 02 ATEX 1090X
Design Threaded barrel,M18 × 1
Dimensions 71 mm Housing material Stainless steel, V4A (1.4404) Terminal chamber cover material plastic, Ultem Terminal chamber housing material plastic, LCP-GF30 Active area material Plastic, LCP Admissible pressure on front cap Max. tightening torque housing nut 25 Nm Electrical connection Terminal chamber, Removable cage clamp terminals
Clamping ability
Vibration resistance 55 Hz (1 mm) Shock resistance 30 g (11 ms) Protection class IP68 / IP69K MTTF 6198 years acc. to SN 29500 (Ed. 99) 40 °C Packaging unit 1
Switching state LED,Yellow
ï 2.1 mA ð 1.2 mA
ð 15 bar
suited for M16 x 1.5 cable glands
2
ð 1.5 mm
Functional principle
Inductive sensors detect metal objects con­tactless and wear-free. For this purpose they use a high-frequency electromagnetic AC field that interacts with the target. The sensors hosting a ferrite core coil generate the AC field through an LC resonant circuit.
Special versions are available for ambient temperatures between -60°C and +250°C.
Edition • 2018-07-09T17:27:33+02:00
1 / 4 TURCK Inc.
Inductive sensor With extended temperature range BI5-EM18WDTC-Y1X
Distance D 2 x B
Distance W 3 x Sn
Distance T 3 x B
Distance S 1.5 x B
Distance G 6 x Sn
Diameter active area B Ø 18 mm
Edition • 2018-07-09T17:27:33+02:00
2 / 4 TURCK Inc.
Loading...