Turck BI3-M08E-AP6X Data Sheet

Inductive sensor With increased switching distance BI3-M08E-AP6X
Type designation BI3-M08E-AP6X
Ident-No. 4602906
Rated switching distance Sn 3 mm Mounting conditions Flush Secured operating distance Correction factors St37 = 1; Al = 0.3; stainless steel = 0.7; Ms = 0.4 Repeat accuracy Temperature drift Hysteresis 3…15 % Ambient temperature -25…+70 °C
ð (0,81 x Sn) mm
ð 2 % of full scale ð ± 10 %
Threaded barrel, M8 x 1
Nickel-plated brass
Large sensing range
DC 3-wire, 10…30 VDC
NO contact, PNP output
Cable connection
Wiring Diagram
Functional principle
Inductive sensors detect metal objects con­tactless and wear-free. For this, they use a high-frequency electromagnetic AC field that interacts with the target. Inductive sensors generate this field via an RLC circuit with a ferrite coil.
Operating voltage 10…30 VDC Residual ripple DC rated operational current No-load current I Residual current Isolation test voltage Short-circuit protection yes/ Cyclic Voltage drop at I Wire breakage/Reverse polarity protection yes/ Complete Output function 3-wire, NO contact, PNP Switching frequency 2.8 kHz
Design Threaded barrel,M8 × 1 Dimensions 42.1 mm Housing material Metal, CuZn, Nickel-plated Active area material Plastic, PP-GF20 End cap Plastic, PP-GF20 Max. tightening torque housing nut 7 Nm Electrical connection Cable Cable quality 3mm, Gray, Lif9Y-11Y, PUR, 2
Cable cross section
Vibration resistance 55 Hz (1 mm) Shock resistance 30 g (11 ms) Protection class IP67 MTTF 2283 years acc. to SN 29500 (Ed. 99) 40 °C Packaging unit 1
0
e
ð 10 % U
ss
ð 150 mA ð 15 mA ð 0.1 mA ð 0.5 kV
ð 1.8 V
Suited for E-ChainSystems® acc. to manufacturers declaration H1063M
3 x 0.14 mm
2
Switching state LED,Yellow
Edition • 2018-04-24T15:59:18+02:00
1 / 3 TURCK Inc.
Inductive sensor With increased switching distance BI3-M08E-AP6X
Distance D 2 x B
Distance W 3 x Sn
Distance T 3 x B
Distance S 1.5 x B
Distance G 6 x Sn
Diameter active area B Ø 8 mm
Flush installation in brass, aluminium and stainless
steel with the supplied nuts is possible without restric-
tions.
If installed flush in steel, a phase of 45° and min. depth
of 1.7 mm (dimension X) must be observed.
Edition • 2018-04-24T15:59:18+02:00
2 / 3 TURCK Inc.
Loading...