Inductive sensor
With increased switching distance
BI3-M08E-AN6X
Type designation BI3-M08E-AN6X
Ident-No. 4602907
Ident. no. 4602907
Rated switching distance Sn 3 mm
Mounting conditions Flush
Secured operating distance
Correction factors St37 = 1; Al = 0.3; stainless steel = 0.7; Ms = 0.4
Repeat accuracy
Temperature drift
Hysteresis 3…15 %
Ambient temperature -25…+70 °C
ð (0,81 x Sn) mm
ð 2 % of full scale
ð ± 10 %
■ Threaded barrel, M8 x 1
■ Nickel-plated brass
■ Large sensing range
■ DC 3-wire, 10…30 VDC
■ NO contact, NPN output
■ Cable connection
Wiring Diagram
Functional principle
Inductive sensors detect metal objects contactless and wear-free. For this, they use a
high-frequency electromagnetic AC field that
interacts with the target. Inductive sensors
generate this field via an RLC circuit with a
ferrite coil.
Operating voltage 10…30 VDC
Residual ripple
DC rated operational current
No-load current I
Residual current
Isolation test voltage
Short-circuit protection yes/ Cyclic
Voltage drop at I
Wire breakage/Reverse polarity protection yes/ Complete
Output function 3-wire, NO contact, NPN
Switching frequency 2.8 kHz
Design Threaded barrel,M8 × 1
Dimensions 42.1 mm
Housing material Metal, CuZn, Nickel-plated
Active area material Plastic, PP-GF20
End cap Plastic, PP-GF20
Max. tightening torque housing nut 7 Nm
Electrical connection Cables
Cable quality 3mm, Gray, Lif9Y-11Y, PUR, 2
Cable cross section
Vibration resistance 55 Hz (1 mm)
Shock resistance 30 g (11 ms)
MTTF 2283 years acc. to SN 29500 (Ed. 99) 40 °C
Packaging unit 1
Switching state LED,Yellow
0
e
ð 10 % U
ss
ð 150 mA
ð 15 mA
ð 0.1 mA
ð 0.5 kV
ð 1.8 V
Suited for E-ChainSystems® acc. to manufacturers
declaration H1063M
3 x 0.14 mm
2
Edition • 2018-07-12T17:54:30+02:00
1 / 3 TURCK Inc.
Inductive sensor
With increased switching distance
BI3-M08E-AN6X
Distance D 2 x B
Distance W 3 x Sn
Distance T 3 x B
Distance S 1.5 x B
Distance G 6 x Sn
Diameter active area B Ø 8 mm
Flush installation in brass, aluminium and stainless
steel with the supplied nuts is possible without restric-
tions.
If installed flush in steel, a phase of 45° and min. depth
of 1.7 mm (dimension X) must be observed.
Edition • 2018-07-12T17:54:30+02:00
2 / 3 TURCK Inc.