Turck BI20-G47-AZ3X Data Sheet

Inductive sensor BI20-G47-AZ3X
Type designation BI20-G47-AZ3X
Ident-No. 13088
Rated switching distance Sn 20 mm Mounting conditions Flush Secured operating distance Correction factors St37 = 1; Al = 0.3; stainless steel = 0.7; Ms = 0.4 Repeat accuracy Temperature drift Hysteresis 3…15 % Ambient temperature -25…+70 °C
ð (0,81 x Sn) mm
ð 2 % of full scale ð ± 10 %
Threaded barrel, PG36
Chrome-plated brass
AC 2-wire, 20…250 VAC
DC 2-wire, 10…300 VDC
NO contact
Cable connection
Wiring Diagram
Functional principle
Inductive sensors detect metal objects con­tactless and wear-free. For this, they use a high-frequency electromagnetic AC field that interacts with the target. Inductive sensors generate this field via an RLC circuit with a ferrite coil.
Operating voltage 20…250VAC Operating voltage 10…300 VDC AC rated operational current DC rated operational current Frequency Residual current Isolation test voltage Surge current Voltage drop at I Output function 2-wire, NO contact Smallest operating current I Switching frequency 0.02 kHz
Design Threaded barrel,G47 Dimensions 70 mm Housing material Metal, CuZn, Chrome-plated Active area material Plastic, PA12-GF30 End cap Plastic, PA66-GF25 Max. tightening torque housing nut 90 Nm Electrical connection Cables Cable quality 5.2mm, LifYY, PVC, 2 Cable cross section
Vibration resistance 55 Hz (1 mm) Shock resistance 30 g (11 ms) Protection class IP67 MTTF 2283 years acc. to SN 29500 (Ed. 99) 40 °C
Switching state LED,Red
e
m
ð 400 mA ð 300 mA ï 50…ð 60 Hz ð 1.7 mA ð 1.5 kV ð 8 A (ð 10 ms max. 5 Hz) ð 6 V
ï 3 mA
3 x 0.75 mm
2
Edition • Rev. C • 2018-04-27T17:08:39+02:00
1 / 3 TURCK Inc.
Inductive sensor BI20-G47-AZ3X
Distance D 2 x B
Distance W 3 x Sn
Distance T 3 x B
Distance S 1.5 x B
Distance G 6 x Sn
Diameter active area B Ø 47 mm
Edition • Rev. C • 2018-04-27T17:08:39+02:00
2 / 3 TURCK Inc.
Loading...