BI1.5-EH6.5K-Y1
Inductive Sensor
Features
Smooth barrel, Ø 6.5 mm
■
Stainless steel, 1.4427 SO
■
DC 2-wire, nom. 8.2 VDC
■
Output acc. to DIN EN 60947-5-6 (NAMUR)
■
Cable connection
■
ATEX category II 1 G, Ex zone 0
■
ATEX category II 1 D, Ex zone 20
■
SIL2 (Low Demand Mode) acc. to IEC
■
61508, PL c acc. to ISO 13849-1 at HFT0
SIL3 (All Demand Mode) acc. to IEC 61508,
■
PL e acc. to ISO 13849-1 with redundant
configuration HFT1
Technical data
Type
ID no. 1004600
Rated switching distance 1.5mm
Mounting conditions Flush
Secured operating distance ≤(0.81×Sn)mm
Correction factors St37 = 1; Al = 0.3; stainless steel = 0.7;
Repeat accuracy ≤2% of full scale
Temperature drift ≤ ± 10 %
Hysteresis 1…10%
Ambient temperature -25…+70°C
Output function 2-wire, NAMUR
Switching frequency 5kHz
Voltage Nom.8.2VDC
Non-actuated current consumption ≥2.1mA
Actuated current consumption ≤1.2mA
Approval acc. to KEMA 02 ATEX 1090X
Internal capacitance (Ci)/inductance (Li) 150 nF/150 µH
Device marking
Design
Dimensions 23.6mm
Housing material Stainless steel, 1.4427 SO
Active area material Plastic, PA12-GF30
End cap Plastic, PP
Electrical connection Cable
Cable quality Ø4mm, Blue, Lif9YYW, PVC, 2m
BI1.5-EH6.5K-Y1
Ms = 0.4
É II 1 G Ex ia IIC T6 Ga/II 1 D Ex ia IIIC
T95 °C Da
(max. Ui = 20 V, Ii = 60 mA, Pi = 80 mW)
Smooth barrel,6.5 mm
Wiring diagram
Functional principle
Inductive sensors detect metal objects
contactless and wear-free. For this, they use a
high-frequency electromagnetic AC field that
interacts with the target. Inductive sensors
generate this field via an RLC circuit with a
ferrite coil.
BI1.5-EH6.5K-Y1 | 22-04-2021 15-50 | Technical modifications reserved
Hans Turck GmbH & Co. KG | 45466 Mülheim an der Ruhr, Germany | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com 1|3

Technical data
Core cross-section
2x0.25mm
2
Vibration resistance 55Hz (1 mm)
Shock resistance 30g (11 ms)
Protection class IP67
MTTF 6198years acc. to SN 29500 (Ed. 99) 40
°C
Mounting instructions
Mounting instructions/Description
Distance D 2 x B
Distance W 3 x Sn
Distance T 3 x B
Distance S 1.5 x B
Distance G 6 x Sn
Diameter active
Ø6.5mm
area B
Hans Turck GmbH & Co. KG | 45466 Mülheim an der Ruhr, Germany | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com 2|3
BI1.5-EH6.5K-Y1 | 22-04-2021 15-50 | Technical modifications reserved

Operating Instructions
Intended use This device fulfills the directive 2014/34/EC and is suit-
ed for use in explosion hazardous areas according to EN
60079-0:2012 + A11 and EN 60079-11:2012.Further it is suited for use in safety-related systems, including SIL2 as per IEC
61508.In order to ensure correct operation to the intended purpose it is required to observe the national regulations and directives.
For use in explosion hazardous areas conform to classification II 1 G and II 1 D (Group II, Category 1 G, electrical equipment
for gaseous atmospheres and category 1 D, electrical equipment for dust atmospheres).
Marking (see device or technical data sheet)
Local admissible ambient temperature -25…+70 °C
Installation/Commissioning These devices may only be installed, connected and oper-
Installation and mounting instructions Avoid static charging of cables and plastic devices. Please
Service/Maintenance Repairs are not possible. The approval expires if the device is
É II 1 G and Ex ia IIC T6 Ga and É II 1 D Ex ia IIIC T95 °C
Da acc. to EN 60079-0, -11
ated by trained and qualified staff. Qualified staff must have
knowledge of protection classes, directives and regulations
concerning electrical equipment designed for use in explosion
hazardous areas.Please verify that the classification and the
marking on the device comply with the actual application conditions.
This device is only suited for connection to approved Exi circuits according to EN 60079-0 and EN 60079-11. Please observe the maximum admissible electrical values.After connection to other circuits the sensor may no longer be used in
Exi installations. When interconnected to (associated) electrical equipment, it is required to perform the "Proof of intrinsic
safety" (EN60079-14).Attention! When used in safety systems,
all content of the security manual must be observed.
only clean the device with a damp cloth. Do not install the
device in a dust flow and avoid build-up of dust deposits on
the device.If the devices and the cable could be subject to
mechanical damage, they must be protected accordingly.
They must also be shielded against strong electro-magnetic
fields.The pin configuration and the electrical specifications
can be taken from the device marking or the technical data
sheet.
repaired or modified by a person other than the manufacturer.
The most important data from the approval are listed.
Hans Turck GmbH & Co. KG | 45466 Mülheim an der Ruhr, Germany | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com 3|3