turck NIC...-M30 Series, NICPM30-8P8-0, 3-RSC12T, NICP-M30-IOL2P8X-H1141, NICSM30-IOL2P8-0 Instructions For Use Manual

...
Your Global Automation Partner
Instructions for Use
NIC…-M30
Inductive Coupler
2
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com
3
Contents
1 About these Instructions 5
1.1 Target groups 5
1.2 Explanation of Symbols Used 5
1.3 Other documents 5
1.4 Feedback about these instructions 5
2 Notes on the Product 6
2.1 Product identification 6
2.2 Scope of delivery 6
2.3 Legal requirements 6
2.3.1 Device classification according to SRD EN 300 440 6
2.4 Manufacturer and Service 7
3 For Your Safety 8
3.1 Intended use 8
3.2 General safety notes 8
4 Product Description 9
4.1 Device overview 9
4.1.1 Indication elements 9
4.2 Properties and features 9
4.3 Operating principle 9
4.4 Functions and operating modes 10
4.4.1 Transfer of 2 standard PNP signals 10
4.4.2 IO-Link mode 10
4.4.3 Transfer of 8 standard PNP signals 11
4.4.4 Foreign object detection – FOD 11
4.5 Technical accessories 12
5 Mounting 13
5.1 Power with angle offset 13
5.2 Power with lateral offset 14
5.3 Distance between primary side and secondary side 14
6 Connecting 15
6.1 Transfer of 2 standard PNP signals (digital inputs) 15
6.2 IO-Link mode 15
6.3 Transfer of 8 standard PNP signals 16
7 Commissioning 17
7.1 IO-Link mode 17
8 Operation 18
8.1 LEDs 18
8.2 Foreign object detection (FOD) 18
9 Troubleshooting 19
10 Maintenance 20
11 Repair 20
11.1 Returning Devices 20
Contents
4
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com
12 Decommissioning 20
13 Disposal 20
14 Technical Data 21
14.1 Technical data of the primary side 21
14.2 Technical data of the secondary side 21
14.3 Technical data of inductive transfer system 22
14.4 Design 22
15 Appendix: EU Declaration of Conformity 23
5
1 About these Instructions
These operating instructions describe the structure, functions and the use of the product and will help you to operate the product as intended. Read these instructions carefully before using the product. This is to avoid possible damage to persons, property or the device. Retain the in­structions for future use during the service life of the product. If the product is passed on, pass on these instructions as well.
1.1 Target groups
This document is written for specially trained personnel , and must be read carefully by anyone who is responsible for the mounting, commissioning, operation, maintenance, disassembly or disposal of the device.
1.2 Explanation of Symbols Used
The following symbols are used in these instructions:
DANGER
DANGER indicates a dangerous situation with high risk of death or severe injury if not avoided.
WARNING
WARNING indicates a dangerous situation with medium risk of death or severe in­jury if not avoided.
CAUTION
CAUTION indicates a dangerous situation of medium risk which may result in minor or moderate injury if not avoided.
NOTICE
NOTICE indicates a situation which may lead to property damage if not avoided.
NOTE
NOTE indicates tips, recommendations and useful information on specific actions and facts. The notes simplify your work and help you to avoid additional work.
u
CALL TO ACTION
This symbol denotes actions that the user must carry out.
a
RESULTS OF ACTION
This symbol denotes relevant results of actions.
1.3 Other documents
n Data sheet n Declaration of Conformity n IO-Link devices commissioning manual
1.4 Feedback about these instructions
We make every effort to ensure that these instructions are as informative and as clear as pos­sible. If you have any suggestions for improving the design or if some information is missing in the document, please send your suggestions to techdoc@turck.com.
Notes on the Product
6
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com
2 Notes on the Product
2.1 Product identification
NIC P – M30 – IOL 2P8X H1141
NIC
Functional Principle
Functional principle NIC Non-flush inductive coupler
IOL
Technology
Technology
IOL IO-Link
P
Component
Component P Primary side (Emitter) S Secondary side (Reciever)
M30
Design
Design M30 M30 × 1.5 threaded barrel
2 P 8 X
Electrical Version
Indication X LED
Voltage range 8 24 VDC, short-circuit proof
Output mode P PNP
Number of channels 2 2 channels 8 8 channels
H1141
Electrical Connection
Electrical connection H1141 Integrated connector,
M12 × 1, 4-pin
0.3-RKC4.4T Pigtail: 0.3 m cable with female connec­tor, M12 × 1, 4-pin
0.3-RSC12T Pigtail: 0.3 m cable with male connector, M12 × 1, 12-pin
2.2 Scope of delivery
n Primary side or secondary side n 2 M30 nuts for mounting
2.3 Legal requirements
The device is subject to the following EC directives:
n 2014/53/EU (RED Directive) n 2011/65/EU (RoHS II Directive)
2.3.1 Device classification according to SRD EN 300 440
The device complies with the following classifications according to ETSI EN 300 440:
n Receiver category 3 n Generic short range device
7
2.4 Manufacturer and Service
Hans Turck GmbH & Co. KG Witzlebenstraße 7 45472 Muelheim an der Ruhr Germany
Turck supports you with your projects, from initial analysis to the commissioning of your applic­ation. The Turck product database contains software tools for programming, configuration or commissioning, data sheets and CAD files in numerous export formats. You can access the product database at the following address: www.turck.de/products For further inquiries in Germany contact the Sales and Service Team on:
n Sales: +49 208 4952-380 n Technology: +49 208 4952-390
Outside Germany, please contact your local Turck representative.
For Your Safety
8
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com
3 For Your Safety
The product is designed according to state-of-the-art technology. However, residual risks still exist. Observe the following warnings and safety notices to prevent damage to persons and property. Turck accepts no liability for damage caused by failure to observe these warning and safety notices.
3.1 Intended use
These devices are designed solely for use in industrial areas. Inductive couplers are used for the contactless and bidirectional transfer of power and data via an air interface (max. 7mm) in industrial automation applications. The devices consist of a primary side and a secondary side. The primary side supplies power to the secondary side via an air interface. The secondary side supplies in turn data from the connected sensors as well as sensors and actuators connected in IO-Link mode. The devices may only be used as described in these instructions. Any other use is not in accord­ance with the intended use. Turck accepts no liability for any resulting damage.
3.2 General safety notes
n The device only meets the EMC requirements for industrial areas and is not suitable for use
in residential areas.
n The device may only be assembled, installed, operated, parameterized and maintained by
professionally-trained personnel.
n The device may only be used in accordance with applicable national and international regu-
lations, standards and laws.
n Do not place any metal objects such as screw drivers in the electrical field between the
primary and secondary side.
9
4 Product Description
The devices have a cylindrical housing style with an M30×1.5 male thread. An M12 connector (male) directly on the housing is used to connect the NICP-M30-IOL2P8X-H1141 primary side. The NICP-M30-8P8-0,3-RSC12T primary side and the NICS-M30-IOL2P8-0,3-RKC4.4T secondary side are provided with a 0.3 m connection cable with an M12 male connector (pigtail).
4.1 Device overview
36/5
62
77
M30 x 1.5
16.5
M12 x 1
LED
36/5
71.5
76.4
4
M30 x 1.5
16.5
44.6
ø 15
M12 x 1
36/5
71.5
76.4
4
M30 x 1.5
16.5
44.6
ø 15
M12 x 1
Fig.1: Primary side NICP-M30­IOL2P8X-H1141
Fig.2: Primary side NICP­M30-8P8-0,3-RSC12T
Fig.3: Secondary side NICS­M30-IOL2P8-0,3-RKC4.4T
4.1.1 Indication elements
The NICP-M30-IOL2P8X-H1141 primary side is provided with an LED for status indication.
4.2 Properties and features
n Threaded barrel, M30 × 1.5 n Chrome-plated brass n DC 4-wire, 24 VDC
4.3 Operating principle
Inductive couplers transfer power based on the principle of inductive coupling power transfer – ICPT. The oscillation frequency is 200kHz. Data is transferred on a carrier frequency of 2.4GHz.
C/Q
DO
DC
C/Q
DI
DC
2,4 GHz
ICPT
Signal processing
Near field
DC/AC converter
Power
Signal processing
Near field
AC/DC converter
Power
Primary side Secondary side
Fig.4: Block diagram
Inductive couplers consist of a primary side and a secondary side. The devices are used for the contactless and bidirectional transfer of power and data via an air interface (max. 7mm) in in­dustrial environments. The primary side supplies power to the secondary side via an air inter­face. The secondary side supplies in turn data from the connected sensors as well as sensors and actuators connected in IO-Link mode.
Product Description
10
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com
4.4 Functions and operating modes
The inductive couplers can be used to transfer 2 or 8 standard PNP signals or can be run in IO­Link mode. Different primary sides of the inductive coupler must be used depending on the op­erating mode.
4.4.1 Transfer of 2 standard PNP signals
To transfer 2 standard PNP signals, the devices NICP-M30-IOL2P8X-H1141 (primary) and NICS­M30-IOL2P8-0,3-RKC4.4T (secondary) are required. The secondary side with a connected VB2­FSM4.4-2FKM4 junction system (Ident no. 6930560) transfers 2 standard PNP signals to the primary side. The junction system is not required if sensors with 2 PNP outputs (e.g. power clamps) are used.
Fig.5: Setup example for the transfer of 2 standard PNP signals
4.4.2 IO-Link mode
The devices NICP-M30-IOL2P8X-H1141 (primary) and NICS-M30-IOL2P8-0,3-RKC4.4T (second­ary) are required for IO-Link mode. IO-Link mode provides a bidirectional IO-Link communica­tion between an IO-Link master and an IO-Link device via the air interface.
Fig.6: Setup example for IO-Link communication
11
4.4.3 Transfer of 8 standard PNP signals
The following devices are required for the transfer of 8 standard PNP signals:
n NICP-M30-8P8-0,3-RSC12T (primary side) n NICS-M30-IOL2P8-0,3-RKC4.4T (secondary side) n TBIL-M1-16DIP (I/O hub for IO-Link)
If the secondary side is connected to a TBIL-M1-16DIP I/O hub for IO-Link, up to 8 standard PNP signals can be transferred via the inductive coupler. For this a PNP sensor is connected to the ports of the TBIL-M1-16DIP on channel A. The PNP signals of the sensors on the primary side can be connected to a digital input card via the plug connector on the device.
Fig.7: Setup example for the transfer of 8 standard PNP signals
4.4.4 Foreign object detection – FOD
The FOD function (Foreign Object Detection) detects metallic foreign objects between the primary and secondary side. The power supply of the device is switched off if the FOD detects foreign objects.
Product Description
12
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com
4.5 Technical accessories
Ident No. Type Description
6814017 TBEN-L5-8IOL Compact multiprotocol I/O module for Ethernet, 8 IO-
Link master channels, 4 universal digital PNP channels, 2 A, channel diagnostics
6814024 TBEN-S2-4IOL Compact multiprotocol I/O module for Ethernet, 4IO-
Link master channels, 4 universal digital PNP channels,
0.5 A, channel diagnostics
6814102 TBIL-M1-16DXP I/O hub for IO-Link, 16 universal digital PNP channels
(only in connection with primary side NICP-M30­IOL2P8X-H1141)
6814100 TBIL-M1-16DIP I/O hub for IO-Link, 16 digital PNP inputs
6814101 TBIL-M1-8DOP I/O hub for IO-Link, 8 digital outputs (only in connection
with primary side NICP-M30-IOL2P8X-H1141)
6827386 BL67-4IOL IO-Link 1.1 master for BL67 modular fieldbus system, 4
IO-Link ports and 4 programmable PNP ports
6827385 BL20-E-4IOL IO-Link 1.1 master for BL20 modular fieldbus system, 4
IO-Link ports and 4 programmable PNP ports
6825482 USB-2-IOL-0002 IO-Link 1.1 adapter with integrated USB interface,
1-channel operation in IOL or SIO mode
6625503 RKC4.4T-2/TXL Connection cable, M12 female connector, straight, 4-pin,
cable length: 2 m, sheathing material: PUR, black
6625339 RKC12T-2/TXL Connection cable, M12 female connector, straight, 12-
pin, cable length: 2 m, sheathing material: PUR, black
6625608 RKC4.4T-2-
RSC4.4T/TXL
Connection cable, M12 female connector, straight 4-pin, cable length 2 m, M12 plug connector, straight, 4-pin sheathing material PUR, black
6932705 RKC12T-2-
CS19.121/TXL
Connection cable, M12 female connector, straight 12­pin, cable length 2 m, M23 plug connector, straight, 19­pin, for direct connection to BL67 base module with M23 plug connector
13
5 Mounting
The maximum tightening torque of the housing nuts is 40 Nm.
Check whether the housing material and the degree of protection is sufficient for your
application in terms of resistance, vibration resistance and cleaning (see chapter 14, Technical Data.
Align the front faces of the primary and secondary side to each other. Observe here the
tables “Power with angle offset”, “Power with lateral offset” and “Distance between primary and secondary side”.
Fit the device at the intended mounting location. Observe the minimum mounting dis-
tances.
D
S
T
N
Fig.8: Mounting distances
Distance
T 60 mm
N 26.5 mm
S 30 mm
D 60 mm
5.1 Power with angle offset
α
D
Fig.9: Angle offset
Distance D Angle α Power
2 mm 7.5° 12 W
4 mm 15° 12 W
5 mm 20° 12 W
7 mm 25° 12 W
8 mm 30° 1 W
Mounting
14
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com
5.2 Power with lateral offset
M
D
Fig.10: Lateral offset between primary side (right) and secondary side (left)
Distance D Offset M Power
0 mm 5 mm 12 W
2 mm 5 mm 12 W
4 mm 5 mm 12 W
5 mm 3 mm 12 W
7 mm 2 mm 12 W
8 mm 1 mm 1 W
5.3 Distance between primary side and secondary side
D
Fig.11: Distance between primary side (right) and secondary side (left)
Distance D Power
0 mm 12 W
2 mm 12 W
4 mm 12 W
6 mm 12 W
7 mm 12 W
8 mm 1 W
15
6 Connecting
6.1 Transfer of 2 standard PNP signals (digital inputs)
Connect sensors (e.g. to a VB2-FSM4.4-2FKM4 2-port junction system). Connect NICS-M30-IOL2P8-0,3-RKC4.4T on the secondary side to a sensor as per the pin
layout.
Connect the primary side NICP-M30-IOL2P8X-H1141 to a controller or a fieldbus device
via an M12 connection cable (e.g. RKC4.4T-2/TXL) as per the pin layout.
4 BK
1 BN3 BU
2 WH
1 24 VDC +
2 Output 2
3 GND – 4 Output 1
Fig.12: Pin layout, primary side Fig.13: Wiring diagram, primary side
4 BK
1 BN 3 BU
2 WH
1 24 VDC +
2 Input 2
3 GND – 4 Input 1
Fig.14: Pin layout, secondary side Fig.15: Wiring diagram, secondary side
6.2 IO-Link mode
NOTE
In IO-Link mode contact 2 cannot be used as a digital input or output.
Connect the secondary side NICS-M30-IOL2P8-0,3-RKC4.4T to an IO-Link device as per the
pin layout.
Connect the primary side NICP-M30-IOL2P8X-H1141 to an IO-Link master via an M12 con-
nection cable (e.g. RKC4T.T-2/TXL) as per the pin layout.
4 BK
1 BN3 BU
2 WH
1 24 VDC +
2 n.c.
3 GND – 4 Output 1 & C/Q (IO-Link)
Fig.16: Pin layout, primary side Fig.17: Wiring diagram, primary side
4 BK
1 BN 3 BU
2 WH
1 24 VDC +
2 n.c.
3 GND – 4 Input 1 & C/Q (IO-Link)
Fig.18: Pin layout, secondary side Fig.19: Wiring diagram, secondary side
Connecting
16
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com
6.3 Transfer of 8 standard PNP signals
NOTICE
2 NICP-M30-8P8-0.3-RSC12T devices on a digital input module
Damage to devices due to overcurrent
Never connect 2 NICP-M30-8P8-0.3-RSC12T devices in parallel to a digital input
module.
Connect sensors to the respective ports of the I/O hub for IO-Link TBIL-M1-16DIP (Ident
no. 6814100). Use here channel A (Pin 4).
Connect the secondary side NICS-M30-IOL2P8-0,3-RKC4.4 to the TBIL-M1-16DIP IO-Link
hub as per the pin layout.
Connect the primary side NICP-M30-8P8-0,3-RSC12T to a fieldbus device or to a controller
with the corresponding PNP inputs as per the pin layout. To connect to a BL67 fieldbus station (e.g. BL67-16DI-P) use the RKC12T-2-CS19.121/TXL connection cable.
2 BU
1 BN
8 GY
9 RD
7 BK
6 YE
5 PK
4 GN
3 WH
10 VT
12 RDBU
11 GYPK
1 24 VDC +
2 GND
3 Output 1 4 Output 2 5 Output 3 6 Output 4 7 Output 5
8 Output 6
9 Output 7 10 Output 8 11 FOD 12 Signal NOK
Fig.20: Pin layout, primary side Fig.21: Wiring diagram, primary side
NOTE
When transferring 8 standard PNP signals, pin 2 cannot be used as a digital input.
4 BK
1 BN 3 BU
2 WH
1 24 VDC +
2 n.c.
3 GND
4 Input 1 & C/Q (IO-Link)
Fig.22: Pin layout, secondary side Fig.23: Wiring diagram, secondary side
17
7 Commissioning
The device is ready for power transfer after the power supply is connected and switched on and after a power up delay of 160ms. The delay for the data transmission is typically 750 ms, but can take longer in individual cases. The length of the delay, for example, may depend on the following factors:
n Connected devices on the secondary side n Set cycle time in the IO-Link master
7.1 IO-Link mode
Set the cycle time on the IO-Link master (min. 10ms). a The IO-Link device is operated at double the cycle time. a The inductive coupler is operational.
Operation
18
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com
8 Operation
On the primary side several components of the secondary side with the same configuration can also be operated (so-called Dynamic Pairing). With the power supply on the primary side a star­tup delay of 10ms must be expected.
8.1 LEDs
LED indication Meaning
Lit Data and power supply transfer error-free
Flashing (10 Hz) Secondary side missing, no communication between
primary and secondary side
Flashing (1 Hz) FOD function active
8.2 Foreign object detection (FOD)
The device is provided with an FOD function (Foreign Object Detection). The FOD detects metal foreign objects in the active area between the primary and secondary side. The device then automatically switches off the power supply. The FOD status is indicated as follows:
Device FOD active
NICP-M30-IOL2P8X-H1141 LED flashes at a frequency of 1Hz.
NICP-M30-8P8X-0,3-RSC12T FOD status pin is set.
As soon as the device no longer detects any metal, the system returns automatically to the op­erational state.
19
9 Troubleshooting
If the device does not function as expected, first check whether ambient interference is present. If there is no ambient interference present, check the connections of the device for faults. If there are no faults, there is a device malfunction. In this case, decommission the device and replace it with a new device of the same type.
Maintenance
20
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com
10 Maintenance
Ensure that the plug connections and cables are always in good condition. The devices are maintenance-free, clean dry if required. The active area between the primary side and the secondary side must be cleared occasionally of any metal contamination (e.g. chips) in order to improve operation.
11 Repair
The device must not be repaired by the user. The device must be decommissioned if it is faulty. Observe our return acceptance conditions when returning the device to Turck.
11.1 Returning Devices
Returns can only be accepted if a declaration of decontamination is enclosed with the device. The declaration can be downloaded from
https://www.turck.de/en/retoure-service-6079.php
and must be completely filled in, and affixed securely and weather-proof to the outside of the packaging.
12 Decommissioning
Remove the connection cable from the power supply and/or processing units. Disconnect the connection cable from the primary side. Disconnect the connection cable from the secondary side. Undo the connections of the device or if necessary the mounting aid for the mounting
area.
Undo if necessary the connection of the device to the mounting aid.
13 Disposal
The devices must be disposed of correctly and must not be included in normal household garbage.
21
14 Technical Data
14.1 Technical data of the primary side
Technical data NICP-M30-IOL2P8X-H1141 NICP-M30-8P8-0,3-RSC12T
Operating voltage 24VDC ± 10 % 24VDC ± 10 %
Operating current 750 mA 750 mA
Nominal distance 0…7 mm 0…7 mm
Ambient temperature -20…+55 °C -20…+55 °C
Output function 4-wire PNP and IO-Link 12-wire PNP
Degree of protection IP67 and IP68 IP67 and IP68
Electrical connection M12 connector, 4-pin Connection cable, 0.3m, with
M12 connector, 12-pin
IP68 means: IP67 + following tests:
n 24 hrs. continuous storage at -25 °C n 24 hrs. continuous storage at +70 °C n 7 day continuous storage in water at a depth of 1 m n 10 temperature shock changes from -25 °C to +70 °C, time per temperature value: 1hour
14.2 Technical data of the secondary side
Technical data NICS-M30-IOL2P8-0,3-RKC4.4T
Output voltage 24VDC ± 10 %
Output function 4-wire PNP and IO-Link
Ambient temperature -20…+55°C
Degree of protection IP67 and IP68
Output current 500 mA
Peak current output 2400 mA for 0.1 ms
10 A for 0.02 ms
Electrical connection Connection cable, 0.3m, with M12 connector,
4-pin
Min. input voltage for High level 8 V
Max. input voltage for Low level 5 V
Input current <4.5 mA
IP68 means: IP67 + following tests:
n 24 hrs. continuous storage at -25 °C n 24 hrs. continuous storage at +70 °C n 7 day continuous storage in water at a depth of 1 m n 10 temperature shock changes from -25 °C to +70 °C, time per temperature value: 1hour
Appendix: Technical Data
22
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com
14.3 Technical data of inductive transfer system
Technical data Inductive transfer system
Standby time 160 ms
Standby power, coupled 4 W
Standby power, not coupled 1 W
IO-Link communication COM2/IO-Link 1.1.1, 38.4kBaud
Rotation 1250 rpm
Short-circuit protection Yes
Reverse polarity protection Yes
14.4 Design
Technical data
Housing material Metal, CuZn, chrome-plated
Material of active face Plastic, PA 12-GF30
23
15 Appendix: EU Declaration of Conformity
Over 30 subsidiaries and over
60 representations worldwide!
www.turck.com
100003896 | 2018/11
100003896