1. SPECIFICATIONS
2. SERIAL NUMBER
3. INSTALLATION
4. CLEANING & POWER CORD
5. BASIC OPERATION
6. TROUBLESHOOTING
7. WARRANTY
....................................................................................
.....................................................................................
...................................................................................
.......................................................................................
................................................................
................................................................................
...........................................................................
SPECIFICATIONS
MODEL COMP H.P V/HZ REFRIGERANT AMP TMKC-34S 1/3 115/60Hz R134a 5.50 TMKC-49S 1/2 115/60Hz R134a 7.00
2
2
3
4
5
6
7~9
TMKC-58S 1/2 115/60Hz R134a 7.00 TMKC-34D 1/3 115/60Hz R134a 5.50 TMKC-49D 1/2 115/60Hz R134a 7.00 TMKC-58D 1/2 115/60Hz R134a 7.00
SERIAL NUMBER
The serial number is located on the rating label which is on interior left side wall. Please retain the unit’s serial number for service purpose.
2
INSTALLATION
1. GOOD AIR CIRCULATION
- Please make sure to avoid any partition or objects that may stop the air flow
- Please make sure there is enough space for air circulation to the rear of the
unit. Recommended space between the rear of the unit to the wall is at least 5 inches
2. PLACE ABOVE STRONG FOUNDATION
- Please make sure that the floor where the unit will be placed can support
the total weight plus any other contents that it may hold
3. DO NOT PLACE NEAR HEAT
- Please make sure to avoid hot corners and locations near stoves
- High ambient temperature will significantly reduce cooling efficiency
4. INDOOR USAGE ONLY
- This unit is designed and tested for indoor use only
- Outdoor usage will void its warranty
5. STABILIZATION
- Turn leg levelers counter-clockwise in order to level the unit properly
6. LEVELING
- Please make sure that the unit levels from the front to the back and side to side
7. UNIT NEEDS TO BE PLUGGED TO A DEDICATED OUTLET
8. PLACE BLACK CONDENSATE PAN FROM THE BACK OR FRONT. MAKE SURE PADS ARE INSTALLED UPWARDS AND A DRAIN HOSE IS IN PAN
3
CLEANING
1. CLEANING STAINLESS STEEL INTERIOR AND EXTERIOR
: Damage to stainless steel finish due to improper use of cleaning products or
non- recommended products is NOT covered under this product's warranty.
• Do
- Use warm, soapy water and a soft, clean cloth or sponge
- Rinse surfaces with clean, warm water and dry immediately to avoid water spots
• DO NOT USE
- Abrasive or harsh cleaners
- Ammonia
- Chlorine bleach
- Concentrated detergents or solvents
- Metal or plastic-textured scouring pads
- Vinegar-based products
- Citrus-based cleaners
2. CLEANING THE CONDENSER FINS
- To maintain proper refrigeration performance, the condenser coil must be free of dust, dirt, and grease This will require periodic cleaning. condenser fins should be cleaned at least every three months (90 days) or as needed
3. CLEAN THE GASKET
- The door gasket should be cleaned frequently to maintain proper sealing
4. CHECK AFTER CLEANING
- Check the unit again for safety
- Check that the unit is operating properly
POWER CORD
1. POWER CORD
- Please make sure that the power cord is connected to the proper voltage
- The power cord must be connected to a protected circuit with the correct voltage and amperage
- Turn ʻoffʼ the power switch before disconnecting the power cord, whenever performing maintenance functions or cleaning the refrigerated cabinet
- Compressor warranties are void if compressor burns out due to improper voltage
2. RE-STARTING
- If disconnected, wait for 5 minutes before re-starting
4