Turbo Air TCDD-36-2-H Installation Manual

Turbo Air Speeds up the Pace of Innovation
Direct Cooling Type Deli / Bakery Cases Installation and Operation Manual
Please read this manual completely before attempting to install or operate this equipment.
TCDD-36-2-H TCDD-48-2-H TCDD-72-2-H TCDD-96-4-H
TCDD-36-2-L TCDD-48-2-L TCDD-72-2-L TCDD-96-4-L
www.turboairinc.com
CONTENTS
PAGE
INTRODUCTION
SPECIFICATIONS
INSTALLATION
Damage inspection
Location of display
Leveling of display
OPERATING INSTRUCTIONS
Power switch Light switch Temperature control Thermometer Placing the product
MAINTENANCE & CLEANING
Condenser coil
TROUBLESHOOTING
Merchandiser not functioning Merchandiser is warm Lights are not working
3
4
5
6
7
8
WIRING DIAGRAM
WARRANTY
9
10 - 12
INTRODUCTION
This owner’s manual has important information. Please read the entire manual before installing your new Turbo Air Open Display Merchandiser. For specific questions not answered on this manual, please call:
CUSTOMER SERVICE DEPARTMENT
TURBO AIR
4184 E. Conant St.
Long Beach, CA 90808
1-800-381-7770
Please write down the model and serial number of your merchandiser for future references:
MODEL NUMBER
SERIAL NUMBER
WARNING
Keep this manual in a safe place for your reference.
Failure to read this manual in its entirety can result in misuse of the equip­ment, which may cause personal injury or equipment failure.
WARNING! Your Display Merchandiser must be connected to a dedicated outlet for proper operation.
SPECIFICATIONS
Model
Dimension
(W x D x H) in.
TCDD-36-2-H
36.5 x 30 x 50.2
Electricity
Full Load Amperes
Compressor
Refrigerant
Lighting
Defrost
Net Weight
Model TCDD-36-2-L
Dimension
(W x D x H) in.
36.5 x 30 x 41.9
6.1A
9.6W X 3
411 lbs.
TCDD-48-2-H
48.5 x 30 x 50.2
120V/1PH/60HZ
6.1A
HK6A1C2U CAJ4476Y
R-134A
13.2W X 3
Timed off defrost
467 lbs.
TCDD-48-2-L
48.5 x 30 x 41.9
TCDD-72-2-H
72.5 x 30 x 50.2
11A
20.4W X 3 13.2W X 6
639 lbs.
TCDD-72-2-L
72.5 x 30 x 41.9
TCDD-96-4-H
96.5 x 30 x 50.2
TCDD-96-4-L
96.5 x 30 x 41.9
11A
802 lbs.
Electricity
Full Load Amperes
Compressor
Refrigerant
Lighting
Defrost
Net Weight
6.1A
9.6W X 2
359 lbs.
120V/1PH/60HZ
6.1A
HK6A1C2U CAJ4476Y
R-134A
13.2W X 2
Timed off defrost
421 lbs.
11A
20.4W X 2 13.2W X 4
525 lbs.
11A
710 lbs.
Loading...