Turbo Air TCB-5R Operator’s Manual

CAUTION!
PLEASE KEEP POWER
SWITCH ON BEFORE
OPERATING THIS EQUIPMENT
Turbo Air Speed up the Pace of Innovation
Display Cases Bakery Cases Installation and Operation Manual
COMBINATION CASE
TCB-5R
www.turboairinc.com
CONTENTS
PAGE
SPECIFICATION
INSTALLATION
PACKAGING MATERIAL
LIGHTS
SHELVES
ELECTRICAL INFORMATION
WIRING DIAGRAM
OPERATING INSTRUCTIONS
FRONT CURVED GLASS
MAINTENANCE & CLEANING
TROUBLE SHOOTING
WARRANTY
2
3
4
4
4
5
6
7-8
9
10-11
12
13-15
SPECIFICATIONS
MODEL COMP H.P V/Hz REFRIGERANT AMPS WEIGHT
TCB-5R 1/3 115V/60Hz R-134A 9 1004
2
INSTALLATION
INSPECTION FOR DAMAGE
Customer is responsible for checking for damage. First inspect crate as soon as it arrives. Prior to signing if crate is damaged make sure you note that on bill of lading.
If after uncrating there is concealed damage and crate was in good condition you must call Customer Service at Turbo Air. Concealed damage must be reported within 24 hours of receiving unit. Bill of lading will be requested faxed to claim department. Pictures may be requested of unit and crating.
LOCATION OF BAKERY CASE
Installation Clearance :
86 inch at the top, 20 inch at the rear and 12 inch at the cash inside.
CAUTION : Damage to case and glass can result if pushed on. Do not push curved glass, end glass, doors or door frames.
Do not place Bakery Case in the following locations ; near source of heat, excessive air movement, open doors, and direct sunlight.
Move the Bakery Case to the final location before removing shipping skid.
Condenser is in back of Bakery Case. Do not block inlet.
LEVELING OF BAKERY CASE
Four leveling legs are provided for leveling Bakery Case. Use a leveler to make sure unit is leveled on all four corners.
If unit is not leveled drainage of water will not drain properly and doors will not close properly. Leveling legs can be adjusted accordingly.
3
PACKAGING MATERIAL
Remove all tape that holds life up glass and doors in place. Some residue will be left and this can be removed with glass cleaner.
Remove all plastic ties that hold shelves and brackets for shelves.
LIGHTS
Make sure lights are in their lamp holders. Also make sure plugs for lamp holders are completely plugged in. If they are loose it may cause lamp holder to burn.
SHELVES
To install shelves in desired position front glass must be open and rear doors removed.
Remove doors by lifting upwards and then out of bottom track one at a time. Put doors in a safe location. Lift front glass upwards till fully open.
Where shelf height is desired install the shelf support in shelf standard slot (see drawing).
Install shelves on rear shelf support as shown. Curved part of shelf must be toward front of case if not air flow will be blocked. Snap shelf into retainer clip on the shelf support, this keeps shel from moving (see drawing).
After installing all shelves close front glass and reinstall doors.
4
ELECTRICAL INFORMATION
BAKERY CASE MUST BE GROUNDED
Only a licensed electrician must install all electrical on Bakery Case.
All electrical must be done in accordance with applicable electrical standards.
A dedicated breaker is to be used for each Bakery Case.
Electrical must be grounded upon installation
An access hole is provided thru base of case for running electrical up through floor. Also a hole is provided in the back of unit to run electrical. Unit is designed to be hardwired by electrician. Electrical data is located next to electrical junction box. (see drawing)
The Bakery Case comes with a power cord. Cord is 9.8 feet long. The plug is a .
Improper electrical connections can result in serve injury or death. Do not operate Bakery Case with panels or grill removed.
There are two back panels.
Right side panel has light switch, power switch, thermostat, and thermometer. Also compressor service ports, electrical condensate drain pan, fuses, and main board are accessible.
Left side panel allows access to electrical connection box, ballast, and also allows condenser unit to be pulled out.
Front panel is removable to have access to fans.
5