25
Sequential pump circuit
Pre-requisites:
- Push the switch (13) right down.
- Connect at least one pump to channel 1 and
channel 2. LED (16) has to light up .
- Set button "pulse" to "off".
Please observe:
- In the aquarium, the pumps should be fitted in one
line.
- Use rotary knobs (4b) and (6b) to set the
performance.
Connection of two pumps:
The pumps have to be connected up to sock ets (8)
and (11).
Connection of three and more pumps:
- Connect pump 1 up to the socket (8).
- Connect pump 2 up to socket (9), the next pump
up to socket (10), et cetera .
Time interval:
- Push switch (12) into the time range; contrary to the
print, the following applies for sequential pump operation
(8) on socket (9) in case of the f ollowing switch position:
top: 70 to 650 seconds
middle: 8 to 84 seconds
bottom: 1 to 8 seconds
- Use rotary knob (5) to vary this time range. The
time interval set will double for the f ollowing pumps.
Démarrage successif des pompes
Pré-réglages:
- sélecteur (13) en position basse extrême
- raccordez au moins une pompe sur canal 1 et
2. La LED (16) doit s’allumer
- positionnez le bouton „PULSE“ sur „off“
Remarques:
- les pompes doivent être placées sur un seul
axe
- la puissance se règle sur les boutons (4b) et (6b)
Raccordement de 2 pompes:
Raccordez les pompes sur connecteur (8) et (11)
Raccordement de 3 pompes ou plus:
- raccordez la pompe 1 sur connecteur (8)
- pompe 2 sur connecteur (9), suivante sur (10), etc.
T emps d’intervalles:
- positionnez le sélecteur (12) en fonction de la
base de temps choisie et correspondant à une
différence entre (8) et (9) de:
Position haute: 70 à 650 secondes
Position centrale: 8 à 84 secondes
Position basse: 1 à 8 secondes
- le bouton (5) permet la variation de la base de
temps. P our les pompes suivantes, connecteur
(10) et (11), la base de temps est doublée.