
TUNCMATIK REGULINE SERIES AUTOMATIC VOLTAGE REGULATOR
Models: REGULINE 2000 / REGULINE 3000
Principle of Operation
Automatic Voltage Regulators regulate voltage fluctuations on the mains
and supply connected loads with stable voltage. Low voltages as well as
high voltages can be harmful for sensitive loads.
Voltage Regulators monitor line voltage continuously and with
adjustable transformer regulates the load supply voltage.
Technical Features
¥ CPU Controlled Automatic Voltage Regulation
¥ Wide Voltage Range
¥ Compact Design
¥ Voltage Display
¥ Short Circuit and Over Load Protection
¥ Low / High Voltage Protection
¥ High Temperature Protection
¥ Wide Range of Usage (Sensitive electronic equipment for voltage
fluctuation)
REGULINE 2000 / REGULINE 3000
Front Panel Description
¥ On/Off Button:
Turns On and Off the regulator. Regulator turns on output after 6 sec
delay time.
¥ Voltage display:
Shows input or output voltage when Input/output voltage selection
button is pressed.
Green section on display shows approximately 180-250V range and red
section shows 110-280V range.
¥ Input/Output Voltage Selection Button:
It allows to select input or output voltage on voltage display.
¥ Low/High Voltage Warning LEDs:
According to the selection is done by Input/Output Voltage Selection
Button, if input or output voltage is low the red LED turn on, and if
voltage is high the green LED turn on. If voltage is in acceptable range
LED’s turn off.

Front Panel Back Panel
Voltage Display
Input/Output
Low Voltage Warning
High Voltage Warning
Voltage
LED (Red)
LED (Green)
(On/Off) Button
TECHNICAL SPECIFICATIONS
REGULINE 2000 / REGULINE 3000 - Relay Type
MODEL
CAPACITY
INPUT
Voltage
Voltage range
Frequency
Fuse
OUTPUT
Voltage range
Protection
INDICATORS
High voltage mode (Boost)
Low voltage mode (Buck)
DIMENSIONS AND WEIGHT
Dimensions D x W x H (mm)
Net Weight (kg)
ENVIRONMENTAL
Humidity
Noise level
* 1000W= Power consumed by 10 pcs 100W bulb
** 1500W= Power consumed by 15 pcs 100W bulb
REGULINE 2000 REGULINE 3000
2000 VA
* **
1000 W
10 A 16 A
Short circuit, Over temperature, Output voltage, Over load protection
4.85 5.48
0-95% RH @ 0-40˚C (non-condensing)
220 VAC
140-260 VAC
50 Hz / 60 HZ
220 V ± %10
Red LED
Yellow LED
270 x 144 x 150
Less than <40 dB
3000 VA
1500 W
AC
Output
AC
Input
Circuit
Breaker

Operating Regulator
While the regulator is turned off, connect the power plug to a grounded
wall outlet. Connect your equipment power cables to the grounded
outlet on the back panel of REGULINE 2000 / REGULINE 3000 .
Turn on and Turn off Regulator
To turn on the regulator when it is off, press once on the On/Off button.
To turn off the regulator when it is on, press once on the On/Off button.
Displaying Regulator Input/Output Voltage
If Input/output voltage selection button is not pressed, voltage display
shows output voltage. If button is pressed voltage display shows input
voltage.
All models are single phase.
Response and transfer time is less than 0.5 sec. Waveform is sinusoidal
and does not contain harmonics.
Output delay time is in the range of 6 sec.
Output voltage high protection level is 260V.
If input voltage is between 140-260V regulator can give %100
output power.
Maximum output power varies by the power drawn by load.
Always place your regulator where;
- ventilation is good,
- there is no direct sunlight or nearby heat sources,
- children cannot reach,
- away from water, humidity and oil,
- there is no flammable material,
- there is no risk of falling down.

WARNINGS
¥ Do not overload the regulator above the maximum output power. (See
Technical Specifications Table)
¥ Make sure the total power of connected load does not exceed the
regulator power.
For example; electrical heater, ovens can take excessive power. For this
kind of equipment select suitable regulator power. In order to choose
appropriate power, check Technical Specifications Table in user manual
or ask your authorized sales representative.
¥ Equipment with a compressor motor can take very high currents
during start up. If you connect this type of equipment to the regulator
please consider its start up current. All connected equipment’s total
start up currents should not exceed the regulators maximum rated
current.
¥ All equipment to be connected to the regulator should have the same
voltage and frequency rating with regulator and mains. The mains
voltage supplying the regulator should be in the regulators input voltage
range. Do not connect washing machines rated higher than regulators.
¥ Consider CRT TV power two times of the nominal power.
¥ There are dangerous voltage levels in Regulator. There are no user
serviceable parts in it. Do not open it.
¥ Regulator can only be connected with 2-pole, 3-wire grounded outlets.
Do not attempt to connect it with different type of outlets. There is risk of
electrical shock.
¥ In case of emergency to turn off the unit, press Off button and
disconnect the power cord from the source.
¥ Make sure no liquid or foreign objects enter in the regulator.
¥ Do not leave containers with liquid and drinks on or around the
regulator.
¥ This regulator is designed to be used in a controlled (controlled
temperature, indoor, no conductive dust and material) environmental
condition.
¥ In order to avoid overheating make sure ventilation holes are not
covered, do not place the regulator in direct sunlight or nearby heat
sources.
¥ Before cleaning, turn off the regulator and disconnect the power cord.
Do not use liquid or spray cleaners for cleaning.

Üretici & İthalatcı / Manufacturer & Importer:
Tunçmatik Elektrik Malzemeleri Sanayi ve Ticaret A.Ş.
Yenişehir Mah. İmar İskan Blokları Cad. No: 1BU
34779 Ataşehir, İstanbul, Turkey
T : +90.216.314.51.51
F : +90.216.420.35.29
info@tuncmatik.com