USER MANUAL
LITE II
650/850 VA
UNINTERRUPTIBLE POWER SUPPLY
UPS
![](/html/20/20cf/20cf625070031b20501bde09cc309b6b1d9ce9ad0662d68ae4fdb8a7a56efec4/bg2.png)
Compact size, light weight.
Microprocessor control guarantees high reliability.
Equipped with Boost and Buck AVR.
Green Power Function for energy saving.
DC Start Function. (Cold Start)
Provides AC Overload protection.
This UPS is specially designed for Personal Computers with
multi-functions. lts light weight, compact design perfect fits to the
limited working environment. The line of UPS is equipped with boost
and buck AVR to stabilize input voltage range. lt is also built-in with DC
start function. This function enables the UPS to be started up without AC
power supplied. The main features of UPS are listed below:
INTRODUCTION
1. Smart On/Off Button
2. AC Mode: Green Lighting
Battery Mode: Orange Flashing
Fault: Red Lighting
3. AC Input
4. Output Receptacles
5. Circuit Breaker
Front Panel Back Panel
Lite II 650
Lite II 850
1
3
4
5
2
![](/html/20/20cf/20cf625070031b20501bde09cc309b6b1d9ce9ad0662d68ae4fdb8a7a56efec4/bg3.png)
Smart On/Off Button Technology
(Alarm Silence Function)
Press the smart button for minimum 1 second to turn the UPS unit on. If
mains is cut off when UPS is working, UPS starts working in battery
mode and gives audible alarm. If you press smart button once, UPS
audible alarm stops (Alarm Silence Function).
If the smart button is pressed once again, the alarm starts again.
After UPS alarm is silenced, when
battery capacity drops to a critical level
the audible alarm starts automatically
again and cannot be silenced. Press the
smart button until the LED turn into red
then remove your finger to shut down
the UPS unit.
2. Charging
This unit is shipped from the factory with its internal battery
fully charged, however, some charge may be lost during
shipping and the battery should be recharged prior to use.
Turn on the UPS, Plug the unit into an appropriate power
supply and allow the UPS to charge fully by leaving it
plugged in for at least 6 hours with no load (no electrical
devices such as computers, monitors, etc.) connected.
Green LED flashes while UPS charging.
1. Inspection
Remove the UPS from its packaging and inspect it for
damage that may have occurred during shipping. If any
damage is discovered, repack the unit and return it to
the place of purchase.
Smart
On/O
Button
SMART BUTTON TECHNOLOGY ALARM SILENCE FUNCTION