DESCRIPTION
TUBE-TECH ME 1B
mid equalizer
The
TUBE-TECH program equalizer ME 1A
amplifier to restore the loss from the filter.
The filter has a low frequency peak section with 5 selective frequencies, a mid frequency dip
section with 11 selective frequencies, and a high frequency peak section with 5 selective
frequencies.
The filter is placed directly after the input transformer, therefore eliminating noise from the
amplifier when boosting either low- or high frequencies.
The amplifier consists of two tubes (valves) in push-pull configuration (one ECC 83 as the
pre-amp, and one ECC 82 as the output stage), and an output transformer.
Both input and output are balanced (600) and fully floating.
The in/out key switches the equalization in and out without clicks and changes in level, while the
amplifier remain in the signal path.
contains a passive filter and a tube (valve) based
(040319)
LYDKRAFT ApS
Mose Allé 20, DK 2610 Rødovre
Denmark
![](/html/d7/d76d/d76d149ca86fa61e85f463c9172295e937b192af33160222ce34264cca3bf813/bg2.png)
CONTROLS:
LOW FREQUENCY
SECTION:
The low frequency section consists of a
LOW FREQUENCY
switch located to the left.
PEAK
control and a
PEAK: The
LOW
FREQUENCY: The
MID FREQUENCY
SECTION:
DIP: The
MID
FREQUENCY: The
PEAK
control is continuously variable from 0 dB to +10 dB.
It is of the bell type.
LOW FREQUENCY
switch determines at which
frequency the maximum peaking is obtained.
There is a choice of 5 frequencies:
0.2, 0.3, 0.5, 0.7 and 1 kHz.
The mid frequency section consists of a
MID FREQUENCY
-control is continuously variable from 0 dB to -10 dB.
DIP
switch located to the left.
DIP
It is of the bell type.
MID FREQUENCY
switch determines at which
frequency the maximum peaking is obtained.
There is a choice of 11 frequencies:
0.2, 0.3, 0.5, 0.7, 1, 1.5, 2, 3, 4, 5 and 7 kHz.
control and a
(050504)
HIGH FREQUENCY
SECTION:
PEAK: The
HIGH
FREQUENCY: The
IN/OUT:
The high frequency section consists of a
HIGH FREQUENCY
PEAK
-control is continuously variable from 0 dB to +8 dB.
switch located to the left.
PEAK
control and a
It is of the bell type.
HIGH FREQUENCY
switch determines at which
frequency the maximum peaking is obtained.
There is a choice of 5 frequencies:
1.5, 2, 3, 4 and 5 kHz.
The in/out key switches the filter in and out of the signal path.
The amplifier remains in the circuit.
(040319)