The TUBE-TECH compressor CM 1A is based on an opto-coupler as the gain-reduction
element. This non-semiconductor element has a very low harmonic distortion and none of
the non-linearity problems involved when using most semiconductor elements. Furthermore
there is no long-term degradation of the element thus giving it almost infinite life. This
element is placed after the input-transformer and followed by an all tube-based amplifier with
a gain of - dB to +30 dB.
Thus the signal is not fed through any semiconductor circuitry on its way to the output.
The amplifier consists of two dual triodes in push-pull configuration (one ECC 83 as the
pre-amp and phase splitter, and one ECC 82 as the output stage), and an output
transformer.
Both input and output are balanced (600) and fully floating.
The in/out key switches the compressor in and out without clicks.
The amplifier remains in the signal path.
THE SIDECHAIN:
The side chain is the only part of the compressor that contains semiconductors. They are
used for three reasons: First they do not affect the sound reproduction, second they have a
high slew rate, which is of importance for the performance of the compressor and third they
don't take up much room.
It contains two J-FET quad op-amps, one npn-transistor and one FET-transistor, which
handles the signal for the gain-reduction element.
The compressor contains two time constants circuits:
1. Fixed attack and release times
2. Variable attack and release times
The attack/release select switch makes it possible to use these two circuits separately or
combine their functions.
This gives a feature not normally obtained in other compressors:
In the combined (fix. /man.) state, the attack- and release controls makes it possible to
obtain a complex release-time slope. (See page 4)
(080330 JGP)
LYDKRAFT ApSMose Allé 20, DK 2610 Rødovre
Denmark
Page 2
2
COMPRESSOR INTERCONNECTION:
The Link sockets for interconnection of several compressors are located on the rear panel.
A switch (BUS SELECT) on the front selects which compressors are interconnected, and on
which bus they are connected. If you e.g. have 10 compressors in a rack, you can select
compressor 1,5,7 and 8 on bus 1, and compressor 2,3,6 and 9 on bus 2, leaving compressor
4 and 6 in the off position.
Compressors 1,5,7,8 are now interconnected and all four will perform the exact same
compression. This applies to compressor 2,3,6 and 9 as well. Compressor 4 and 6 are
independent.
The interconnection implies that the unit, which performs the most compression, is
controlling the others.
To choose which one you want to control, select the attack/release time, the threshold and
the ratio on that unit, and turn the threshold fully counter clockwise on the reminding
compressors.
It is of course possible to have all the interconnected compressors control each other
simultaneously.
NB:Remember to set the ratio control and the gain control in the same position on
the "slaves". Otherwise the stereo image could be shifted during compression.
The attack/release-control on the slaves will have no effect.
The input/output capability of the side chain-circuit allows up to ten compressors to be linked
together.
(130920)
LYDKRAFT ApS
Mose Allé 20, DK 2610 Rødovre
Denmark
Page 3
3
CONTROLS:
GAIN: The gain control is used to "make up" for the gain loss, which takes
place when the unit is compressing. It is placed after the gain-reduction
circuit and therefore has no influence on the threshold setting. The
gain-control is continuously variable from off to +30 dB.
RATIO: The ratio control varies the ratio by which the input signal is
compressed.
If the ratio selected is to 2:1, and the input signal increases 10 dB, the
output signal is only increased by 5 db. The ratio control is continuously
variable from 2:1 to 10:1.
THRESHOLD:The threshold is the point where the compressor begins its action. It is
defined as the point where the gain is reduced by 1 dB.
The threshold is continuously variable from +20dBU to -40 dBU.
METER:The LED VU-display switch has two positions:
1. Compression
The VU-display is reading gain reduction. Its rest
position is "0 VU", and the amount of compression is
shown as a decreasing deflection in dB.
2. Output
The VU-meter is reading the level at the output
socket.
"0 VU" is equivalent to +4 dBU.
IN/OUT:This leverswitch switches the compressor in and out of the signal path.
The out position bypasses the compressor section, but the amplifier
remains in the signal path.
ATTACK:The attack control chooses how fast/slow the compressor responds to
an increase in the input signal.
The attack control is continuously variable from 0.5 to 300 milliseconds.
RELEASE:The release control chooses how fast/slow the compressor responds to
a decrease in the input signal.
The release control is continuously variable from 0,05 to 10 seconds.
(071206)
LYDKRAFT ApSMose Allé 20, DK 2610 Rødovre
Denmark
Page 4
4
ATTACK/RELEASE SELECT:This switch selects how the compressor reacts to an increase (attack) or
2. Manual.
Attack time: from 0.5 msec to 300 msec
Release time: from 0.05 sec to 10 sec
3. Fix/man.
This setting combines the release times of fixed and manual
mode. The attack time is as in the fixed mode.
The fix/man mode always has a fast attack, but it is possible to obtain a release time
depending on the input signal, e.g. get a fast release when the peak disappears, then
superseded shortly thereafter by the release time selected by the release control.
From the time the peak disappears, until the selected release time takes over, is dependent
upon the setting of the attack control.
That is, the attack control changes function from a pure attack control, to a control of delay
with the same time range.
The more CW the attack control is turned, the longer time before the release control
takes over.
The more CCW the attack control is turned, the shorter time before the release control
takes over.
This function is valid only if the time of the peak is shorter than the setting of the attack
control.
If the peak of the program is longer than the setting of the attack control, or if the attack
control has reached the full CCW position, it will respond as in the manual mode.
The fix/man mode acts as an automatic release function with a constant fast attack time and
fast release time for short peaks and a longer release times for longer peaks.
This setting is mainly intended for use on program material (overall compression).
BUS SELECT:
Interconnects several compressors on bus 1 or bus 2.
If the compressor is left in the off position, it works entirely
independently.
(071206)
LYDKRAFT ApS
Mose Allé 20, DK 2610 Rødovre
Denmark
Page 5
5
ADJUSTMENT PROCEDURE:
CAUTION:
Before making any adjustment let the unit heat-up at least 15 min.
Observe that the offset-voltage measured at the side chain jack socket, when the
THRESHOLD is off, is not greater than +/- 15 mV DC in both position "fixed" and
"manual".
(Tip is bus 1 and ring is bus 2).
If the voltage exceeds this value, replace either U1 or U2.
THE GRE SHALL BE MARKED BETWEEN 0.800-1.000
ADJUSTMENT OF BASIC GAIN:
1) Apply a signal of 1 kHz, -30,0 dBU into the input of the compressor.
2) Turn the GAIN-control fully clockwise.
3) Set the RATIO-control at 2:1
4) Adjust the pre-set GAIN (located on amp/psu PCB) to an output-reading of 0,0 dBU.
ADJUSTMENT OF COMPRESSION TRACKING:
1) Turn the THRESHOLD-control fully counter-clockwise.
2) Set the RATIO-control at 2:1.
3) Set the BUS-select-switch at 1.
4) Apply a signal of 1 kHz, 0,0 dBU into the input of the compressor.
5) Adjust the GAIN-control to an output-reading of 0,0 dBU.
6) Apply a DC-voltage of +250,0 mV into the side chain jack socket (tip) and observe that
the output level has dropped to -10,0 dB.
7) If this is not the case, adjust the level with P 7, to obtain a drop of exactly -10,0 dB.
(071221)
LYDKRAFT ApSMose Allé 20, DK 2610 Rødovre
Denmark
Page 6
6
ADJUSTMENT OF THE LED DISPLAY READING "VU":
1) Switch the METER-selector to Output.
2) Apply a signal of 1 kHz, 0,0 dBU into the input of the compressor.
3) Adjust the GAIN-control to an output-reading of +4,0 dBU.
4) Adjust P10 to a LED display reading of 0 VU.
The -1 LED shall just turn off and the 0 LED shall just turn on.
ADJUSTMENT OF THE LED DISPLAY READING "COMPRESSION":
1) Turn the THRESHOLD-control fully counter-clockwise.
2) Switch the METER-selector to Comp.
3) Set the RATIO-control at 2:1
4) Apply a signal of 1 kHz, 0,0 dBU into the input of the compressor.
5) Adjust the GAIN-control to an output-reading of 0,0 dBU.
6) Adjust P 9 until the LED display is reading 0 VU.
The -1 LED shall just turn off and the 0 LED shall just turn on.
7) Apply a DC-voltage of +250,0 mV into the side chain jack socket and observe that the
output level has dropped to -10,0 dBU. If this is not the case, adjust the compression
tracking (see above)
8) Adjust P 8 until the LED display is reading -10,0 VU.
The -20 LED shall just turn off and the -10 LED shall just turn on.
9) Remove the DC-voltage from the side chain jack socket.
10) Repeat step 6 - 9.
(130920)
LYDKRAFT ApSMose Allé 20, DK 2610 Rødovre
Denmark
Page 7
7
ADJUSTMENT OF THE RELEASE CONTROL:
1) Set the METER switch in position compression.
2) Set the attack/release SELECT switch in position manual.
3) Apply a signal of 1 kHz, 0,0 dBU into the input of the compressor.
4) Adjust the THRESHOLD-control to a reading of -10 VU of the VU-meter
5) Set the ATTACK-control at fast.
6) Set the RELEASE-control at slow.
7) Switch off the 1 kHz and observe that the VU meter moves to 0 VU in approx. 10 sec.
8) If this is not the case, adjust P 6, to obtain a release time of approximately 10 sec.
(071221)
LYDKRAFT ApSMose Allé 20, DK 2610 Rødovre
Denmark
Page 8
8
TECHNICAL SPECIFICATIONS CM 1A:
Input impedance: 600 Ohms