REGULATED DC POWER SUPPLIES
Regulated DC Power Supplies
PDS SERIES
With compliments
Helmut Singer Elektronik
www.helmut-singer.de info@helmut-singer.de
fon +49 241 155 315 fax +49 241 152 066
Feldchen 16-24 D-52070 Aachen Germany
20V / 18A, Digital meter
PDS20-18
20V / 36A, Digital meter
PDS20-36
36V / 10A, Digital meter
PDS36-10
36V / 20A, Digital meter
PDS36-20
60V / 6A, Digital meter
PDS60-6
60V / 12A, Digital meter
PDS60-12
120V / 6A, Digital meter
PDS120-6
Available from:
OUTLINE
The PDS Series are CE-certified Regulated DC Power
Supply units which comply with Power Supply
Harmonics Current Regulations IEC1000-3-2, and a
power factor of 95% (typical) is cleared. These models
feature high reliability and various types of protection,
and can be used as a power supply for reliability tests,
endurance tests, aging and other electronics parts
tests.
By employing a unique switching and dropper circuit
systems, the output noise is maintained at a minimized
level.The input AC voltage is possible from 90 to 246
volts without any modification. Furthermore, these
models are designed in a smaller size and a lighter
weight compared to conventional models.
Thurlby Thandar Instruments Ltd. Glebe Road, Huntingdon, Cambs.
PE29 7DR U.K. Tel: 01480 412451 e-mail: sales@tti-test.com
Web: www.tt i -t est.com or www.tti.co.uk
PDS20-18
PDS36-10
PDS60-6
PDS60-12
PDS120-6
RS-232C
OPTION
PDS20-36
PDS36-20
76

REGULATED DC POWER SUPPLIES
PDS SER ES
REGULATED DC POWER SUPPLIES
PDS SERIES
FEATURES
Complies with Power Supply Harmonics Current Regulation,
and a Power Factor of 95% (typical)
The PDS Series comply with Power Supply Harmonics Current
Regulations (IEC1000-3-2) as well as "Home Appliance and
General-Purpose Products Harmonics Suppression Control
Guidelines", and never affect the AC supply due to cur rent
harmonics. Fur thermore with a built-in active smoothing filter, a
resulting power factor of 95% (typical) is cleared.
Satisfying CE Mark Certification Requirements
These models satisfy Low-Voltage Standards (IEC1010) and EMC
Standards Requirements.
Series/Parallel Operation
When these models are connected in series, the resulting output
voltage is increased. And when they are connected in parallel, the
resulting output current is increased. For more convenience,
when a master-slave system is used, either a series drive or a
parallel drive operation can be perfor med by a single unit in order
to control the output of all of the other units.
(A master-slave system is possible with up to 3 units in parallel
mode, and up to 2 units in series mode.)
Voltage/Current Simultaneous Digital Display
The bright and easy-to-see displays with 7-segment red LEDs are
designed to display the voltage and current values digitally at the
same time.
Compact, Lightweight Design
When compared with the conventional PD-A Series, the weight is
reduced to 1/2 to 1/3. It can more easily be carried from door to
door than before.
Various Protection Functions
For protection, various protection functions are provided including
OVP (over-voltage protection), OHP (over-heating protection) and
OCP (over-current protection). When a pr otection circuit is
engaged, the power switch is automatically turned of f.
Board-Type Options for External Control
External control is possible using optional board interface. Since a
board can be mounted inside the unit, no extra mounting space is
required. For external control, thr ee types of options ar e available
-- analog (voltage/resistor), GP-IB and RS-232C.
Worldwide AC Voltage Input Design
A wide range of AC power voltages can be input between 90 V and
246 V. Each model is ready to accept worldwide power sources
without switching over the voltage selector.
Voltage/Current Preset (3 points)
The frequently used output values for voltage and current can be
stored in the memory for up to 3 points for each value. The preset
values can be recalled with a touch of a button, making possible
the switching of the output value more quickly.
Single-Dial Control Design
Designed with easy operation in mind, the operation conditions
can be set at a press of the push button switch, while all the setup
values can be changed using the rotar y encoder control.
Especially for output voltage and current, high accuracy control is
possible in 10 mV and 10 mA steps respectively. Further mor e, the
variable speed of the control knob can be switched between
SLOW and FAST.
Key Lock Function
A key lock function is provided to fix the setup values for
inhibiting the operation on the front control panel. This is
convenient when long-term energization is required. Also, it is not
necessar y to have to worr y about mis-operation by others if you
leave it on your desk while the experiment is continuing.
With compliments
Helmut Singer Elektronik
www.helmut-singer.de info@helmut-singer.de
fon +49 241 155 315 fax +49 241 152 066
Feldchen 16-24 D-52070 Aachen Germany
Optional Accessories
GP-IB Interface Card : IF-30GP
RS-232C Interface Card : IF-30RS
Analog Card : IF-30AN
Rack Mount Adapter : RK-605E (EIA size)
77

REGULATED DC POWER SUPPLIES
SPECIFICATIONS
Model PDS20-18 PDS20-36
Output
Output voltage range (V) 0 - 20 0 - 20
Output current range (A) 0 - 18 0 - 36
Rated output power (W) 360 720
Output terminal Front & Rear Rear
Voltage regulation characteristics
Line regulation 0.005% +1 mV (for ± 10% source voltage fluctuation)
Load regulation 0.005% +2 mV (for 0 to 100% fluctuation)
Ripple /noise, p-p (By 20MHz Scope) 30 mVp-p
Ripple /noise, rms (5 Hz to 1 MHz) 1 mVrms 1.5 mVrms
Transient response (typ.) 100μsec
Temperature coefficient (typ.) ± 100 ppm/°C
Rise time Full load / no load 100msec / 100msec
Fall time Full load / no load 150msec / 1000msec
Current regulation characteristics
Line regulation 5mA 10mA
Load regulation 5mA
Ripple noise, rms (5 Hz to 1 MHz) 10mA 10mA
Temperature coefficient ± 100ppm/°C
Display
Voltage display, accuracy
Current display, accuracy
In constant voltage/ current operation CV LED on/ CC LED on
Output signals
Alarm signal output Open collector, active Low Operation functions
Operation function
OVP key Displays OVP circuit operating voltage on front
KEYLOCK (LOCAL) key Locks keys and knobs (except POWER switch).
PRESET 1 - 3 keys Used with MEM key to memorize three output
MEM key Used with PRESET keys to memorize three output
FAST/SLOW key Changes output voltage and current setting speed.
ON/OFF control Enabled with input contact signals.
POWER switch shut-down Enabled with input contact signals.
Output voltage remote sensing Compensates for 1 V voltage drop on single side.
Protection
Over voltage protection (OVP) POWER switch off at setting value
Over current protection (OCP) POWER switch of f at setting value
Overheat protection (OHP) POWER switch off at setting value
Soft OVP (OVD) Set from external controller in remote control mode.
Environmental request
Operating temperature / humidity range 0 to 40 °C / 30 to 80 % RH
Stocking temperature / humidity range –20 to 70 °C / 20 to 80 % RH
To-GND voltage ± 250 VDC
Cooling method Fr ont air intake type forced air cooling with
Power source
Input voltage AC 90 to AC 246V, 50/60 Hz without setting change.
Power factor (typ) 95%
Power consumption (typ) 560 W 1100 W
Power efficiency (typ) 65% 65%
Dimensions / Weight
Dimensions
Maximum dimensions
Weight (approx.) 6.3 kg 7.2 kg
Options
Analog I/O board V/I controlled by external voltage or resistance.
GP-IB interface board V/I set/read, Output ON/OFF, AC shout down.
RS-232C interfaceboard V/I set/read, Output ON/OFF, AC shout down.
Output capacity extension Parallel connection control : Master-slave system,
(W ¥ H ¥ D) mm 210 × 124 × 405
(23±5°C) 3 1/2 digits LED, 0.1% rdg ± 2 digits, 10mV accuracy
(23±5°C) 3 1/2 digits LED, 0.5% rdg ± 2 digits, 10mA accuracy
(W ¥ H ¥ D) mm 210 × 141 × 465.5
78

REGULATED DC POWER SUPPLIES
PDS SER ES
REGULATED DC POWER SUPPLIES
PDS SERIES
PDS36-10 PDS36-20 PDS60-6 PDS60-12 PDS120-6
0 - 36 0 - 36 0 - 60 0 - 60 0 - 120
0 - 10 0 - 20 0 - 6 0 - 12 0 - 6
360 720 360 720 720
Front & Rear Rear Front Front Front
1 mVrms 2 mVrms
1mA 5mA 1mA 5mA 1mA
5mA 10mA 5mA 10mA 5mA
(5ms one pulse)
panel, which is variable between 10 and 110% of F.S.
Also removes remote control.
voltages and currents.
voltages and currents.
POWER switch off when soft OVP is active.
fan motor Insulation resistance
520 W 1050 W 520 W 1050 W 1050 W
70% 70% 72% 72% 72%
6.3 kg 7.2 kg 6.3 kg 7.2 kg 7.2 kg
up to 3 units / Series connection control: Master-slave system, up to 2 units
79
210 × 124 × 405
210 × 141 × 425.5
Available from:
Measurably better value
Thurlby Thandar Instruments Ltd. Glebe Road, Huntingdon, Cambs. PE29 7DR U.K.
Tel: 01480 412451, Fax: 01480 450409, e-mail: sales@tt i-test.com
Web: www.tt i-test.com or www.t ti.co.uk