4.0 Scale and Reference Level Setup
The MPA1-BD allows the displayed scale and digital reference level to
be
set from the front panel. The unit may display either an EBU Digital
or
PPM scale and the reference level for the AES inputs may be set
from
-15dBFS to
-24dBFS.
To enter the setup mode, the phase button must be held
down
continuously for about 7 seconds. After this time, the phase indicator
will
change to an orange colour, the meters will change to a static display
and
the loudspeakers will
mute.
At this time the meters will display the current setup of the unit. If no
change is desired, a brief press on the phase button will return the unit
to
normal
operation.
Once in the setup mode, the input selector switch chooses between
four
options which will be displayed on the left
meter:
•
EBU Digital with Peak Hold
(default)
•
EBU Digital without Peak
Hold
•
PPM with Peak
Hold
•
PPM without Peak
Hold
The meter type is indicated by the orange level indicator being adjacent
to
the respective scale reference. The peak hold is indicated by a red bar
at
the top of the
display.
The right hand display indicates the AES reference level in dBFS. This
is
indicated by the orange marker being adjacent to the EBU scale
marker
for
the relevant level. The reference level may be changed by moving
the
volume control. The available reference levels
are:
•
-15dBFS
•
-18dBFS
(default)
•
-20dBFS
•
-22dBFS
•
-24dBFS
Note that the lack of a scale line at -15dB means that the -15dBFS case
is
indicated at -16dB on the front panel
scale.
Once a suitable setup has been found, the selection may be stored
by
once more holding the phase button down for approximately 7
seconds,
after which the unit will return to normal
operation.
The MPA-1BD may also be returned to factory default settings by
pressing
and holding the phase button for greater than 30
seconds.