Unless otherwise stated TSL equipment may be installed at any angle or position within
an operating temperature range of 5° - 30° C .
All TSL equipment conf o rm s to th e EC Low Voltage Directive:
EC Low Voltage Directive (73/23/EEC)(OJ L76 26.3.73)(LVD).
Amendment: (93/68/EEC) (OJ L220 30.8.93).
The earth pin on the IEC mains inlet connector is connected to the metal frame of the
equipment, to 0 volts on the internal DC PSU and to signal ground, unless otherwise
stated. All metal panels are bonded togethe r.
In all cases , the frame of the equipment must be ear thed on installation.
Due consideration for cooling requirements must be given when mounting the equipment.
Ideally 1RU of rack spac e should be left above and below the unit.
Check that the fuse rating is correct for the local power (mains) supply. Replacement
fuses must be of the same rating and type for continued protection against fire risk.
Do not switch on until all connections are made.
WARRANTY, MAINTENANCE AND REPAIR
All TSL equipment is guaranteed for one year from the date of delivery to the customer’s
premises. If the equipment is to be stored for a significant period, please contact TSL
concerning a possible extended warranty period.
Failure during warranty
If any TSL product should fail or become faulty within the warranty period, first please
check the PSU fuses.
All maintenance work must be carried out by trained and competent personnel.
Technical support information
E-Mail ad dress: support@televisionsy stems.ltd.uk
Telephone Support Number for the UK and Europe: +44 (0) 1628 670000
Telephone Support Number for the USA only: 1 877 591 2108
AMU2-8HD+/3G 2 Issue 1
USO RESTRITO
TSL Returns Proc e dure
Please telephone +44(0)1628 676200 (Fax: +44 (0)1682 676299) and ask for Production
Sales who will provide a Returns Number. This will enable us t o track the unit eff ectively
and will provide some information prior to the unit arriving.
For each item, this unique Returns Number must be included with the Fault Report sent
with the unit.
A contact name and telephone number are also required with the Fault Report sent with
the unit.
Fault report detail s req uir e d.
• Company:
• Name:
• Address:
• Contact Name:
• Telephone No:
• Returns Number:
• Symptoms of the fault (to include switch setting positions, inp ut signals etc):
Packing
Please ensure that the unit is well packed as all mechanical damage is chargeable. TSL
recommends that you insure your equipment for transit damage.
The original packaging, when available, should always be used when returning
equipment..
If returned equipment is received in a damaged condition, the damage should be
reported both to TSL and the ca r ri er imm e dia tely.
This handbook covers the AMU2-8HD+ and AMU2-8HD-3G Audio Monitoring Units.
The AMU2-8HD+/3G are full rack 2RU x 310mm deep Audio Monitoring Units with eight
TSL 53 segment bargraphs.
The following features are standard:
• Four AES/EBU inputs.
• Two HD/SDV auto sensing inputs.
• Re clocked output of input.
• Two Stereo analogue inputs.
• Phase reverse switch.
• Out-of-phase error indication.
• Down converted video or SDV output
• Additive output switch selection.
• Composite output.
• Headphone outputs with LS muting.
• Fixed and variable st ereo line outputs of selected pair.
• Four simultaneous line outputs.
• Dolby compatible D and E.
• Metadata display.
• EBU digital, UK PPM and EBU PPM scales available.
• Internal amplifier.
• 1080p50 / 1080p/60 capable (3G units only)
AMU2-8HD+/3G 5 Issue 1
USO RESTRITO
2.0 Front Panel Controls
2.1 Input and Meter Selection Buttons
AES1, 2, 3 & 4 AES input. This isselected by first pressing the AES select
button, then selecting A(1/2),B(3/4), C(5/6 ), D(7/8) respectively
on the LS monitoring panel.
Anal ogue 1 & 2 These inputs are selected by pressing the Phase
Reverse/function button and then the AES/ANLG button on the
input select panel. The signals are displayed on bargraph A
(1/2) and B (3/4).
S/HD (Auto sensing) This is selected by pressing the S/HD button 1 or 2 and then
selecting GP1 to GP4. The de-embedded SDV or HD is then
displayed on the bargraphs A(1/2),B(3/4), C(5/6), D(7/8)
respectively. Selecting e.g.group 1 and 2 together allows all
eight channels to be monitored.
Dolby Encoded Dolby can either be carried on an AES bit stream or
as embedded HD or SD. To select the Dolby function press the
DOLBY button after selecting either AES or S/HD buttons. If a
valid Dolby signal is present the Dolby button will illuminate
steady red. If a Dolby signal is not present or is lost the button
will flash. To select one pair from one group containing two
Dolby signals on each pair, select the group (1, 2, 3 or 4) from
the H/SDV input and then either A, B, C, or D from the input
selector to choose thepair.
Letterbox Shows the composite output as 16:9 aspect ratio on a 4:3
monitor.
Ø Rev (Function) Momentary phase reverse between A1 and A2 outputs.
Brightness To increase the brightness of the ba rgraph disp lay
Press phase reverse and monitoring select A. To decrease the Brightness press phase reverse and monitoring select B.
Reference Marker To turn the reference marker on and off press phase
Reverse and the CUT button.
AMU2-8HD+/3G 6 Issue 1
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.