TSI Instruments 9565 Series, VELOCICALC 9565 Series Operation And Service Manual

ENERGY AND COMFORT
Ventilation Testing
VELOCICALC
®
Air Velocity Meter
Model 9565 Series
Copyright
TSI Incorporated / 2011 / All rights reserved.
Address
TSI Incorporated / 500 Cardigan Road / Shoreview, MN 55126 / USA
Fax No.
(651) 490-3824
LIMITATION OF WARRANTY AND LIABILITY (effective July 2000)
Seller warrants the goods sold hereunder, under normal use and service as described in the operator's manual, shall be free from defects in workmanship and material for twenty-four (24) months, or the length of time specified in the operator's manual, from the date of shipment to the customer. This warranty period is inclusive of any statutory warranty. This limited warranty is subject to the following exclusions: a. Hot-wire or hot-film sensors used with research anemometers, and certain other
components when indicated in specifications, are warranted for 90 days from the date of shipment.
b. Parts repaired or replaced as a result of repair services are warranted to be free from
defects in workmanship and material, under normal use, for 90 days from the date of shipment.
c. Seller does not provide any warranty on finished goods manufactured by others or on any
fuses, batteries or other consumable materials. Only the original manufacturer's warranty applies.
d. Unless specifically authorized in a separate writing by Seller, Seller makes no warranty
with respect to, and shall have no liability in connection with, goods which are incorporated into other products or equipment, or which are modified by any pe rson other than Seller.
The foregoing is IN LIEU OF all other warranties and is subject to the LIMITATIONS stated herein. NO OTHER EXPRESS OR IMPLIED WARRANTY OF FITNESS FOR PARTICULAR PURPOSE OR MERCHANTABILITY IS MADE.
TO THE EXTENT PERMITTED BY LAW, THE EXCLUSIVE REMEDY OF THE USER OR BUYER, AND THE LIMIT OF SELLER'S LIABILITY FOR ANY AND ALL LOSSES, INJURIES, OR DAMAGES CONCERNING THE GOODS (INCLUDING CLAIMS BASED ON CONTRACT, NEGLIGENCE, TORT, STRICT LIABILITY OR OTHERWISE) SHALL BE THE RETURN OF GOODS TO SELLER AND THE REFUND OF THE PURCHASE PRICE, OR, AT THE OPTION OF SELLER, THE REPAIR OR REPLACEMENT OF THE GOODS. IN NO EVENT SHALL SELLER BE LIABLE FOR ANY SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES. SELLER SHALL NOT BE RESPONSIBLE FOR INSTALLATION, DISMANTLING OR REINSTALLATION COSTS OR CHARGES. No Action, regardless of form, may be brought against Seller more than 12 months after a cause of action has accrued. The goods returned under warranty to Seller's factory shall be at Buyer's risk of loss, and will be returned, if at all, at Seller's risk of loss.
Buyer and all users are deemed to have accepted this LIMITATION OF WARRANTY AND LIABILITY, which contains the complete and exclusive limited warranty of Seller. This LIMITATION OF WARRANTY AND LIABILITY may not be amended, modified or its terms waived, except by writing signed by an Officer of Seller.
Service Policy
Knowing that inoperative or defective instruments are as detrimental to TSI as they are to our customers, our service policy is designed to give prompt attention to any problems. If any malfunction is discovered, please contact your nearest sales office or representative, or call Customer Service department at (800) 874-2811 (USA) or (1) 651-490-2811 (International).

CONTENTS

CHAPTER 1 UNPACKING AND PARTS IDENTIFICATION ............. 1
CHAPTER 2 SETTING-UP ................................................................. 3
Supplying Power to the Model 9565 Series .................................... 3
Installing the Batteries ............................................................... 3
DIP Switch Settings ................................................................... 3
Do not attempt to charge alkaline batteries. .............................. 4
Using the AC Adapter ................................................................ 4
Connecting Ventilation or IAQ Probes ............................................ 4
Using the Telescoping Thermoanemometer Prob es ...................... 5
Extending The Probe ................................................................. 5
Retracting The Probe ................................................................ 5
Do not use the instrument or probes near hazardous
voltage sources since serious injury could result. ................. 5
Using the Pressure Ports (9565-P) ................................................. 5
Connecting the Static Pressure Probe ...................................... 6
Connecting an Optional Pitot Probe or Airflow
(straight pitot) Probe .............................................................. 6
Do not use the instrument or probes near hazardo us
voltage sources since serious injury could result. ................. 7
Thermocouple Ports ....................................................................... 8
Connecting the Thermocouples ................................................ 8
Connecting the Optional Bluetooth Portable Printer Device ........... 9
Connecting to a Computer .............................................................. 9
CHAPTER 3 OPERATION ............................................................... 11
Keypad Functions ......................................................................... 11
Common Terms ............................................................................ 12
Menus ........................................................................................... 13
ZERO PRESSURE ............................................................................. 13
DISPLAY SETUP ............................................................................... 13
SETTINGS ....................................................................................... 14
FLOW SET UP .................................................................................. 14
VOC SETUP ..................................................................................... 15
ACTUAL/STANDARD SETUP .............................................................. 16
DATA LOGGING ............................................................................... 17
Measurements ......................................................................... 17
Log Mode/Log Settings ............................................................ 17
Choose Test ............................................................................ 22
Name Test ............................................................................... 23
View Data ................................................................................ 24
View Stats ................................................................................ 24
View Samples .......................................................................... 25
iii
Print Test .................................................................................. 26
Delete Data .............................................................................. 26
% Memory ................................................................................ 28
ZERO CO ......................................................................................... 28
APPLICATIONS ................................................................................. 29
CALIBRATION .................................................................................. 30
DISCOVER BLUETOOTH .................................................................... 30
Printing Data Using the Portable Printer ....................................... 31
TRAKPRO™ Data Analysis Software ............................................. 31
LogDat2™ Downloading Software ................................................ 31
CHAPTER 4 MAINTENANCE .......................................................... 33
Recalibration ................................................................................. 33
Cases ............................................................................................ 33
Storage .......................................................................................... 33
CHAPTER 5 TROUBLESHOOTING ................................................ 35
APPENDIX A SPECIFICATIONS ..................................................... 37
APPENDIX B OPTIONAL PLUG-IN PROBES ................................ 41
These Application Notes can be found under TSI ’s w eb site:
http://www.tsi.com
TSI-106
Traversing a Duct to Determine Average Air Velocity or Volume
TSI-107 Using the VELOCICALC
®
Meter to Measure Pressure
TSI-109 Converting Standard Velocity to Actual Velocity TSI-114 Use of K-Factors with the VELOCICALC
®
Meter
TSI-124 Heat Flow Calculations TSI-138 Percent Outdoor Air Calculation and Its Use TSI-141 Turbulence Intensit y Measurements TSI-142
Draft Rate: A Determining Factor in the Quantification of
Human Comfort TSI-147 Photo-Ionization Detection (PID) Technology TSI-150 Using Bluetooth® Communications
iv
Loading...