INSTALLING THE 854050/854051
INTO ENVIRONMENTAL ENCLOSURE
This guide will help you quickly attach the 10 m
connection cable included with the Lufft WS300 (TSI
P/N 854050)/ Lufft WS500 (TSI P/N 854051) to the
DustTrak™ Environmental Monitor.
QUICK START GUIDE
METROLOGY STATION
Unpacking the (854050 /
854051) Metrology Station
1. Unpack and verify that all the items listed in the
following table are present.
2. Contact TSI immediately if items are missing or
broken.
Tools Needed for Installation
_______________
TSI and TSI logo are registered trademarks of TSI Incorporated. DustTrak is a trademark of TSI Incorporated.
Thiamis is a trademark of Netronix Inc.

Disconnect power from the instrument. The instrument
SHOULD NOT have power during this installation
procedure.
1. Remove the hole plug in the enclosure and install
the cable gland and jam nut.
2. One end of the 10 m connection cable for the
metrology station has been stripped back and ends
added for connections inside the enclosure.
3. Insert the wire end
of the cable through
the gland. Tighten
(hand tight) the
gland around the
cable to prevent
leakage.
4. Insert the
red and
black wires
into the
connector as
shown.
5. Attach RS-485/SDI-12
Communication Wires
to green connector as
shown. A small flat
blade screw driver can
be used to tighten the
connector to the
wires.
6. Insert the green
connector into
the Thiamis
1000 Node
RS-485 socket.
7. Install the connector as shown to the DIN rail inside
the enclosure.
Installation
-2-

8. Attach the other end of the cable to weather
station. Tighten (hand tight) with a 14-mm open
ended wrench (see figure to right).
9. See the weather station manual for mounting
instructions and specifications.
10. Reapply power to the instrument.
11. Environet can be used to pair the weather station
to the Thiamis 1000.
a. Click Add Sensor in the device configuration.
b. Select Lufft from the pull-down menu and
click Save.
-3-

USA Tel: +1 800 680-1220
UK Tel: +44 149 4 459200
France Tel: +33 1 41 19 21 99
Germany Tel: +49 241 523030
India Tel: +91 80 67877200
China Tel: +86 10 8219 7688
Singapore Tel: +65 6595 6388
TSI Incorporated – Visit our website www.tsi.com for more information.
P/N 6008414 Rev. B ©2018 TSI Incorporated Printed in U.S.A.