TSI Incorporated VelociCalc 8345, VelociCalc 8346, VelociCalc 8347, VelociCalc 8347A Operation And Service Manual

Ventilation Testing/Balancing
Model 8345/8346/8347/8347A
VELOCICALC®
Air Velocity Meters
1980277, Revision E
November 2002
Model 8345/8346/8347/8347A
VELOCICALC
Air Velocity Meters
®
Operation and Service Manual
1980277, Revision E
November 2002
U.S. INTERNATIONAL
Sales and Sales and Customer Service: Customer Service: (800) 874-2811 (001 651) 490-2811 (651) 490-2811 Fax:
Fax:
(651) 490-3824 (001 651) 490-3824
SHIP/MAIL TO: E-mail address:
TSI Incorporated answers@tsi.com 500 Cardigan Road Website: Shoreview, MN 55126-3996 USA www.tsi.com
Copyright TSI Incorporated / August 2000–2002 / All rights reserved.
Address
TSI Incorporated / 500 Cardigan Road / Shoreview, MN 55126 / USA
Fax No.
(651) 490-3824
LIMITATION OF WARRANTY AND LIABILITY. Seller warrants the goods sold hereunder, under normal use and service as described in the operator's manual, shall be free from defects in workmanship and material for twenty-four (24) months, or the length of time specified in the operator's manual, from the date of shipment to the customer. This warranty period is inclusive of any statutory warranty. This limited warranty is subject to the following exclusions:
a. Hot-wire or hot-film sensors used with research anemometers, and
certain other components when indicated in specifications, are warranted for 90 days from the date of shipment.
b. Parts repaired or replaced as a result of repair services are
warranted to be free from defects in workmanship and material, under normal use, for 90 days from the date of shipment.
c. Seller does not provide any warranty on finished goods
manufactured by others or on any fuses, batteries or other consumable materials. Only the original manufacturer's warranty applies.
d. Unless specifically authorized in a separate writing by Seller,
Seller makes no warranty with respect to, and shall have no liability in connection with, goods which are incorporated into other products or equipment, or which are modified by any person other than Seller.
The foregoing is IN LIEU OF all other warranties and is subject to the LIMITATIONS stated herein. NO OTHER EXPRESS OR IMPLIED
WARRANTY OF FITNESS FOR PARTICULAR PURPOSE OR MERCHANTABILITY IS MADE.
TO THE EXTENT PERMITTED BY LAW, THE EXCLUSIVE REMEDY OF THE USER OR BUYER, AND THE LIMIT OF SELLER'S LIABILITY FOR ANY AND ALL LOSSES, INJURIES, OR DAMAGES CONCERNING THE GOODS (INCLUDING CLAIMS
BASED ON CONTRACT, NEGLIGENCE, TORT, STRICT LIABILITY OR OTHERWISE) SHALL BE THE RETURN OF GOODS TO SELLER AND THE REFUND OF THE PURCHASE PRICE, OR, AT THE OPTION OF SELLER, THE REPAIR OR REPLACEMENT OF THE GOODS. IN NO EVENT SHALL SELLER BE LIABLE FOR ANY SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES. SELLER SHALL NOT BE RESPONSIBLE FOR INSTALLATION, DISMANTLING OR REINSTALLATION COSTS OR CHARGES. No Action, regardless of form, may be brought against Seller more than 12 months after a cause of action has accrued. The goods returned under warranty to Seller's factory shall be at Buyer's risk of loss, and will be returned, if at all, at Seller's risk of loss.
Buyer and all users are deemed to have accepted this LIMITATION OF WARRANTY AND LIABILITY, which contains the complete and exclusive limited warranty of Seller. This LIMITATION OF WARRANTY AND LIABILITY may not be amended, modified or its terms waived, except by writing signed by an Officer of Seller.
Service Policy
Knowing that inoperative or defective instruments are as detrimental to TSI as they are to our customers, our service policy is designed to give prompt attention to any problems. If any malfunction is discovered, please contact your nearest sales office or representative, or call TSI's Customer Service department at (800) 874-2811 (USA) and (1) 651-490­2811 (International).

CONTENTS

Chapters
1. Unpacking and Parts Identification ......1
Parts Identification ....................................2
2. Setting-Up................................................ 5
Supplying Power to the V
Installing the Batteries ............................5
Using the Optional AC Adapter ..............5
Auto Power Off Feature .......................... 6
Selecting the Display Units ....................... 6
Using The Telescoping Probe ..................7
Extending The Probe .............................. 7
Retracting The Probe.............................. 7
Articulating Probe (Model 8346/8347A).... 8
3. Operation ................................................. 9
Overview ...................................................9
Keypad Functions ..................................... 9
ON/OFF Key ............................................. 9
Measuring Velocity ................................. 10
Measuring Temperature .........................10
Flow Rate Function................................. 11
Entering Shape and Size...................... 11
Humidity Function (Model 8347/8347A) . 12
Entering Barometric Pressure ..............12
Time Constant Function.......................... 13
ELOCICALC......... 5
Using the Clear, Sample and Statistics
Functions ................................................14
Sample Function................................... 14
Statistics Function................................. 15
Clear Function ......................................16
Printer Port..............................................16
4. Maintenance .......................................... 19
Probe Tip ................................................19
Recalibration ........................................... 19
Cases...................................................... 20
Storage ...................................................20
5. Troubleshooting.................................... 21
Appendixes
A Specifications ........................................25
B DIP Switch Settings ............................... 29
C Standard Velocity vs. Actual Velocity..31
Chapter 1
Unpacking and Parts Identification
Carefully unpack the instrument and accessories from the shipping container. Check the individual parts against the list of components in Table 1. If any are missing or damaged, notify TSI or your local distributor immediately.
Table 1. List of Components Qty Item Description Part/model
1 Model 8345 VELOCICALC or
Model 8346 V Model 8347 V Model 8347A V
1 Carrying Case (8345/46) or
Carrying Case (8347/47A) 4 AA Alkaline batteries 1208013 1 AC Adapter (Optional)
115 V, NEMA-5
230 V, European CEE 7/16
230 V, Great Britain
240 V, Australian 1 Operation and Service Manual 1980277
ELOCICALC or ELOCICALC or
ELOCICALC
8345 8346 8347 8347A 1319125 1319114
2613033 2613078 800169 2613105
1

Parts Identification

1
2
3
1. Keypad
2. Display
3. Printer Interface Port
4. Battery Access Cover
4
2
Chapter 1
Chapter 2
Setting-Up

Supplying Power to the VELOCICALC

The V
ELOCICALC can be powered in one of two
ways: four size AA batteries or the optional AC adapter.
Installing the Batteries
Insert four AA batteries as indicated by the diagram located on the inside of the battery compartment. TSI ships the unit with alkaline batteries. The V operate with either alkaline or NiCd rechargeable batteries. Carbon-zinc batteries are not recommended because of the danger of battery acid leakage. The typical battery life for alkaline batteries at 20°C at 150 ft/min is 10 hours.
Using the Optional AC Adapter
The optional AC adapter allows you to power
ELOCICALC from a wall outlet. When
the V using the AC adapter, the batteries (if installed) will be bypassed. The AC adapter is not a battery charger.
ELOCICALC is designed to
5
Auto Power Off Feature
ELOCICALC’s auto power off feature will
The V automatically power the instrument off after a specified time. In velocity mode, the instrument will power off after 15 minutes provided that the velocity is zero and no keys have been pressed during this time. In temperature mode, the instrument will power off after 15 minutes if no keys have been pressed. This feature can be turned off if desired by switching DIP switch #5 to the OFF position. See Appendix B, DIP Switch Settings.
(Note: Any samples taken will not
ELOCICALC automatically powers off.)
V
be lost if the

Selecting the Display Units

The V
ELOCICALC is capable of displaying the
measured values in several different measurement units, as shown in Table 2-2.
Table 2-2. Choices of Measurement Units
Velocity Temperature Flow Rate
ft/min °F ft3/min
m/s °C m3/hr
l/s
6 Chapter 2