Thermoanemometer
Probe Models
Range Accuracy Resolution Probe Dimensions
962
0 to 9,999 ft/min (0 to 50 m/s)
0 to 200°F (-18 to 93°C)
±3% of reading or ±3 ft/min
(±0.015 m/s), whichever is greater
4&5
±0.5°F (±0.3°C)
6
1 ft/min (0.01 m/s)
0.1°F (0.1°C)
Length 40 in. (101.6 cm)
Tip dia. 0.28 in. (7.0 mm)
Base dia. 0.51 in. (13.0 mm)
Articulating Section Length 6 in. (15.2 cm)
Articulating Knuckle dia. 0.38 in. (9.5 mm)
966
0 to 9,999 ft/min (0 to 50 m/s)
14 to 140°F (-10 to 60°C)
0 to 95% RH
±3% of reading or ±3 ft/min
(±0.015 m/s), whichever is greater
4&5
±0.5°F (±0.3°C)
6
±3% RH
7
1 ft/min (0.01 m/s)
0.1°F (0.1°C)
0.1% RH
Length 40 in. (101.6 cm)
Tip dia. 0.28 in. (7.0 mm)
Base dia. 0.51 in. (13.0 mm)
Articulating Section Length 6 in. (15.2 cm)
Articulating Knuckle dia. 0.38 in. (9.5 mm)
960
0 to 9,999 ft/min (0 to 50 m/s)
0 to 200°F (-18 to 93°C)
±3% of reading or ±3 ft/min
(±0.015 m/s), whichever is greater
4&5
±0.5°F (±0.3°C)
6
1 ft/min (0.01 m/s)
0.1°F (0.1°C)
Length 40 in. (101.6 cm)
Tip dia. 0.28 in. (7.0 mm)
Base dia. 0.51 in. (13.0 mm)
964
0 to 9,999 ft/min (0 to 50 m/s)
14 to 140°F (-10 to 60°C)
0 to 95% RH
±3% of reading or ±3 ft/min
(±0.015 m/s), whichever is greater
4&5
±0.5°F (±0.3°C)
6
±3% RH
7
1 ft/min (0.01 m/s)
0.1°F (0.1°C)
0.1% RH
Length 40 in. (101.6 cm)
Tip dia. 0.28 in. (7.0 mm)
Base dia. 0.51 in. (13.0 mm)
Rotating Vane Probe Models Range Accuracy Resolution Probe Dimensions
995
50 to 6,000 ft/min (0.25 to 30 m/s)
32 to 140°F (0 to 60°C)
±1% of reading ±4 ft/min (±0.02 m/s)
±2.0°F (±1.0°C)
1 ft/min (0.01 m/s)
0.1°F (0.1°C)
Diameter 4 in. (100mm)
496
100 to 3,000 ft/min (0.50 to 15.00 m/s)
32 to 140°F (0 to 60°C)
±3% of reading ±4 ft/min (±0.02 m/s)
±2.0°F (±1.0°C)
1 ft/min (0.01 m/s)
0.1°F (0.1°C)
Diameter 1.5 in. (35mm)
IAQ Probe Models Range Accuracy Resolution Probe Dimensions
980
0 to 5000 ppm CO
2
0 to 95% RH
14 to 140°F (-10 to 60°C)
±3% of reading or ±50 ppm,
whichever is greater
9
CO
2
±3% RH
7
±0.5°F (±0.3°C)
6
1 ppm CO
2
0.1% RH
0.1°F (0.1°C)
Length 7.0 in. (17.8 cm)
Diameter 0.75 in. (1.9 cm)
982
0 to 500 ppm CO
0 to 5000 ppm CO
2
0 to 95% RH
14 to 140°F (-10 to 60°C)
±3% of reading or ±3 ppm,
whichever is greater8CO
±3% of reading or ±50 ppm,
whichever is greater9CO
2
±3% RH
7
±0.5°F (±0.3°C)
6
0.1 ppm CO
1 ppm CO
2
0.1% RH
0.1°F (0.1°C)
Length 7.0 in. (17.8 cm)
Diameter 0.75 in. (1.9 cm)
Thermocuple Probe Models Range Accuracy Resolution Probe Dimensions
792
-40 to 1200°F (-40 to 650°C)
±0.1% of reading +2°F
(±0.056% of reading +1.1°C)
0.1°F (0.1°C) Length 6 in. (15.0 cm) Diameter
794
-40 to 1200°F (-40 to 650°C)
±0.1% of reading +2°F
(±0.056% of reading +1.1°C)
0.1°F (0.1°C) Length 6 in. (15.0 cm) Diameter
4
Temperature compensated over an air temperature range of 40 to 150°F (5 to 65°C).
5
The accuracy statement begins at 30 ft/min through 9,999 ft/min (0.15 m/s through 50 m/s).
6
Accuracy with instrument case at 77°F (25°C), add uncertainty of 0.05°F/°F (0.03°C/°C) for
change in instrument temperature.
7
Accuracy with probe at 77°F (25°C). Add uncertainty of 0.1% RH/°F (0.2% RH/°C) for change
in probe temperature. Includes 1% hysteresis.
8
At 77°F (25°C). Add uncertainty of ±0.2%/°F (0.36%/°C) for change in temperature.
9
At calibration temperature. Add uncertainty of ±0.28%/°F (0.5%/°C) for change in temperature.
Specifications are subject to change without notice.
Probe Specifications
Models 960, 962, 964, 966, 995, 496, 980, 982, 792 and 794