VELOCICALC®
AIR VELOCITY METERS
MODELS 9515, 9535,
9535-A, 9545 AND 9545-A
The dependable TSI VelociCalc® Air Velocity Meters measure air velocity
and temperature. Models are available to calculate ow rate, perform
statistical calculations, and measure humidity with dew point and wet
bulb temperature conversions.
The Model 9515 is an economical choice for a digital air velocity
meter, without compromising accuracy or precision. Professionals
nd them to be the ideal tool for face velocity measurements in
fume hoods, spray booths, or ventilation system checks.
The Models 9535 and 9545 Air Velocity Meters simultaneously
measure and data log several ventilation parameters using a
single probe with multiple sensors. Both models measure velocity,
temperature and calculate ow.
The Model 9545 also measures relative humidity, and calculates
dew point and wet bulb temperature.
Applications
+ HVAC system performance
+ Commissioning
+ Plant maintenance
+ Critical environment certication
+ Duct traverses
Features and Benets
+ Accurate air velocity
measurement
+ Easy to read display
+ Simple to operate
+ Calibration certicate included
Models 9535, 9535-A, 9545 and 9545-A
+ Simultaneously measure temperature and velocity
+ Displays up to three measurements simultaneously
+ Calculates volumetric ow and actual/standard velocity
+ Data log 12,700+ samples and 100 test IDs
+ LogDat2TM downloading software included
+ Articulated probe versions available (9535-A and 9545-A)
+ Measures humidity (Model 9545 and 9545-A)
Model 9545
UNDERSTANDING, ACCELERATED
SPECIFICATIONS
VELOCICALC® AIR VELOCITY METERS
MODELS 9515, 9535, 9535A, 9545 AND 9545A
Velocity
Range (9515) 0 to 4,000 ft/min (0 to 20 m/s)
Range (9535 and 9545) 0 to 6,000 ft/min (0 to 30 m/s)
Accuracy (9515)
1&2
±5% of reading or ±5 ft/min
(±0.025 m/s), whichever
is greater
Accuracy (9535 and 9545)
1&2
±3% of reading or ±3 ft/min
(±0.015 m/s), whichever
is greater
Resolution 1 ft/min (0.01 m/s)
Duct Size (9535 and 9545)
Dimensions
1 to 250 inches in increments of
0.1 in. (
1 to 635 cm in increments
of 0.1 cm
)
Volumetric Flow Rate (9535 and 9545)
Range Actual range is a function of
velocity and duct size
Temperature
Range (9515, 9535 and 9535-A) 0 to 200 °F (-18 to 93°C)
Range (9545 and 9545-A) 14 to 140°F (-10 to 60°C)
Accuracy3 ±0.5°F (±0.3°C)
Resolution 0.1°F (0.1°C)
Relative Humidity (9545 only)
Range 5 to 95% RH
Accuracy4 ±3% RH
Range 0.1% RH
Instrument Temperature Range
Operating (Electronics) 40 to 113°F (5 to 45°C)
Models 9515 and 9535
Operating (Probe) 0 to 200°F (-18 to 93°C)
Model 9545 Operating (Probe) 14 to 140°F (-10 to 60°C)
Storage -4 to 140°F (-20 to 60°C)
Data Storage Capabilities (9535 and 9545)
Range 12,700+ samples and
100 test IDs
Logging Interval (9535 and 9545)
1 second to 1 hour
Time Constant (9535 and 9545)
User selectable
External Meter Dimensions
3.3 in. x 7.0 in. x 1.8 in. (8.4 cm x 17.8 cm x 4.4 cm)
Meter Weight with Batteries
0.6 lbs. (0.27 kg)
Meter Probe Dimensions
Probe Length 40 in. (101.6 cm)
Probe Diameter of Tip 0.28 in. (7.0 mm)
Probe Diameter of Base 0.51 in. (13.0 mm)
Articulating Probe Dimensions
Articulating Section Length 7.8 in. (19.7 cm)
Diameter of Articulating Knuckle 0.38 in. (9.5 mm)
Power Requirements
Four AA-size batteries or AC adapter
9515
Velocity range 0 to 4000 ft/min
(0 to 20.00 m/s)
Velocity range 0 to 6000 ft/min
(0 to 30.00 m/s)
Temperature
Flow
Humidity, wet bulb, dew point
Probe
Variable time constant
Manual data logging
Auto save data logging
Statistics
Review data
LogDat2™
downloading software
Certicate of Calibration
1
Temperature compensated over an air temperature range of 40 to 150°F (5 to 65°C).
2
The accuracy statement begins at 30 ft/min through 4000 ft/min. (0.15 m/s through
20 m/s) for the Model 9515, and 30 ft/min through 6,000 ft/min (0.15 m/s through
30 m/s) for Models 9535 and 9545.
3
Accuracy with instrument case at 77°F (25°C), add uncertainty of 0.05°F/°F
(0.03°C/°C) for change in instrument temperature.
4
Accuracy with probe at 77°F (25°C). Add uncertainty of 0.1% RH/°F (0.2% RH/°C)
for change in probe temperature. Includes 1% hysteresis.
Specications are subject to change without notice.
TSI, the TSI logo and VelociCalc are registered trademarks, and
LogDat2 is a trademark of TSI Incorporated.
+
+ + +
Straight
+ + +
9535,
9535-A
+ +
+ +
Straight or
-A articulated
+ +
+ +
+ +
+ +
+ +
9545,
9545-A
+
Straight or
-A articulated
+
UNDERSTANDING, ACCELERATED
TSI Incorporated
USA Tel: +1 800 874 2811
UK Tel: +44 149 4 459200
France Tel: +33 4 91 11 87 64
Germany Tel: +49 241 523030
Printed in U.S.A.
P/N 2980569 Rev D ©2012 TSI Incorporated
- Visit our website www.tsi.com for more information.
India Tel: +91 80 67877200
China Tel: +86 10 8251 6588