HYDRONIC MANOMETERS
MODELS HM675, HM685
The HM675 and HM685 Hydronic Manometers are used to balance
hydronic heating and cooling systems, check pump performance and to set
balancing valves. They can measure and display dierential, high side and
low side pressure simultaneously, without having to change hose
connections or instrument valve settings. Each model features a backlit
display and operates on four alkaline or NiMH rechargeable batteries.
Features and Benets
+ Measure and display high side, low side, and dierential
pressure simultaneously
+ Robust, splash-proof case
+ Inputs for two temperature probes
Features and Benets (HM685 only)
+ Calculates ow using valve manufacturers’ Cv (Kv) factors
[up to 100 Cv (Kv) can be entered]
+ Calculates heat ow, impeller diameter and brake power
+ Stores up to 4,000 data points to memory for later recall/download
to a PC using CompuDat™ USB Software and USB interface cable
+
Intuitive menu structure for easy navigation and instrument set up
Applications
+ Test and balance heating and cooling systems
+ Check pump performance
+ Set balancing valves
HM675 kit includes hard carrying case, (2) 6.7 ft x ¼-in.
(2 m x 6 mm) hoses with shut-o valves, (2) B&G readout probes, (2)
P/T gauge adapter probes, and power cord.
HM685 kit includes all items in HM675 kit, plus a temperature probe,
CompuDat USB downloading software, and USB
interface cable.
UNDERSTANDING, ACCELERATED
SPECIFICATIONS
HYDRONIC MANOMETERS
MODELS HM675 AND HM685
Pressure
Dierential Range -300 to 300 psi (-2,068 to 2,068 kPa)
Gauge Range -20 to 300 psi (-138 to 2,068 kPa)
(-40 to 610 in. Hg)
Resolution (best) 0.001 psi (0.01 kPa)
(0.01 in. Hg)
Accuracy1 ±1% of reading plus .072 psi
(0.5 kPa) (0.15 in. Hg)
Units
m H2O, bar
psi, in. H2O, ft H2O, kPa, mm Hg, in. Hg,
Pressure Connection ¼” 37• are tting, Male
Temperature
Operating (electronics) 40 to 113°F (5 to 45°C)
Storage -4 to 140°F (-20 to 60°C)
Liquid Media 32 to 180°F (0 to 82°C)
Probe (immersion) -40 to 250°F (-40 to 121 °C)
Resolution 0.1°F (0.1°C)
Accuracy ±0.5% of reading +1.2°F (0.7 °C)
Units °F, °C
Flow (HM685 Only)
Range2 -22,712 to 22,271 m3/h, -99,999 to
99,999 USGPM (-6,309 to 6,309 l/s)
Resolution (best) 0.0001 USGPM (0.00001 l/s)
Accuracy per pressure accuracy + valve
deviation
Units USGPM, UKGPM, m3/h, l/s, l/m
Time Constant
User selectable (1, 5, 10, 20, and 30 seconds)
Product feature comparison HM675 HM685
Dierential, high side, and low side
pressures displayed simultaneously
Reads in in. H2O, ft H2O, psi, in. Hg, m
H2O, kPa, mm Hg, bar
Performs ow calculations
Downloading software and USB cable
Temperature probe
Hard carrying case
Certicate of Calibration
Unique Calculations menu
for determining:
Brake Power
Heat ow
Calculate Cv/Kv
Pump law impeller diameter
Pump law delta P
Pump law brake power
+ +
+ +
+
+
optional +
+ +
+ +
HM675 HM685
+
+
+
+
+
+
Statistics (HM685 only)
min, max, average, sum up to 4,000 readings
Data Storage (HM685 only)
4,000 combined readings, 100 Test IDs
Logging Interval (HM685 only)
User selectable (1 to 3,600 seconds)
External Meter Dimensions
11.1 in. × 4.7 in. × 3.5 in. (28.2 cm × 11.9 cm × 8.8 cm)
Meter Weight with Batteries
2.65 lbs (1.20 kg)
Power Requirements
Four AA-size cells, or AC adapter
1
Accuracy statement applies from -15 to 250 psi (-103 to 1,724 kPa)
2
The ow reading is a calculated value determined from the measured Dierential
pressure, user entered valve ow coecient (Kv or Cv), and uid specic gravity
Specications subject to change without notice.
UNDERSTANDING, ACCELERATED
TSI Incorporated
USA Tel: +1 800 874 2811
UK Tel: +44 149 4 459200
France Tel: +33 1 41 19 21 99
Germany Tel: +49 241 523030
Printed in U.S.A.
P/N 5001534 Rev C ©2016 TSI Incorporated
- Visit our website www.tsi.com for more information.
India Tel: +91 80 67877200
China Tel: +86 10 8219 7688
Singapore Tel: +65 6595 6388