TSI Alnor EBT731, EBT730 Specifications

Page 1
EBT BALOMETER®
CAPTURE HOOD
MODEL EBT731
The EBT731 Balometer™ Capture Hood is a multipurpose electronic air balancing instrument used for taking accurate, direct air volume measurements at diusers and grilles. The corresponding detachable micromanometer can be used with an array of optional probes to
enable various measurement applications. Compatible with LogDat Mobile Remote Reader Software and capture hood stand, the EBT731 maximizes worker productivity and eciency—saving you valuable time on the jobsite for ultimate protability.
Model EBT731-STA Bundle shown.
Applications:
+ Test and balance contractors
+ Commissioning agents
+ Facilities managers
+ Health and safety specialists
+ Ventilation system installers
Features and Benets
+ Ergonomic, lightweight design enables easy one-person operation
on the job
+ Back pressure compensation ensures accurate readings at high
ow rates
+ Detachable digital micromanometer provides additional
measurement capability
+ Multiple hood size options enable measurement of dierent
outlet dimensions
+ Compatible LogDat Mobile Remote Reader and Data Logger Software
option simplies documenting of results and emailing of reports
+ Capture hood stand eliminates the need for ladders (reaching
diusers up to 15 ft. (4.5 m)
UNDERSTANDING, ACCELERATED
Page 2
DETACHABLE
MICROMANOMETER
MODEL EBT730
AIR VOLUME INSTRUMENTS
As standard, the EBT731 Balometer Capture Hood includes a detachable EBT730 micromanometer— one of the most advanced, versatile, and easy to use micromanometers on the market today. The EBT730 features an auto-zeroing pressure sensor that increases measurement resolution and accuracy as well as integrates an intuitive menu structure to facilitate simple operation.
Features and Benets
+ Accurate measurement of pressure, velocity and ow complies with
industry standards
+ Auto-zeroing pressure sensor reduces user-steps and saves time
+ Automatic density correction increases reading accuracy
+ Large, backlit graphic display oers easy-to-use interface
– Up to ve simultaneous measurements
– On-screen messages and instructions
– Multi-language capability
Model EBT730 (Micromanometer shown with standard and optional accessories)
+ Intuitive menu structure for easy operation
+ Integrated Log-Tchebyche duct traverse mapping application simplies
calculations
+ Bluetooth bi-directional communication eases data transfer and permits
use of LogDat Mobile Remote Reader and Data Logger Software for
Android devices
+ Optional pitot, air ow (straight pitot), temperature/relative humidity,
velocity matrix, or plug and play thermoanemometer probes enables
use in multiple applications
Plug and play thermoanemometer probes enables use in multiple applications.
3
2
Page 3
SPECIFICATIONS
MICROMANOMETER MODEL EBT730 AND CAPTURE HOOD MODEL EBT731
Velocity Range
Pitot probes 0.125 to 78 m/s (25 to 15,500 ft/min)
Air ow probe 0.125 to 12.5 m/s (25 to 2,500 ft/min)
Velocity matrix 0.125 to 12.5 m/s (25 to 2,500 ft/min)
Accuracy
±3% of reading ±0.04 m/s (±7 ft/min) at velocities >0.25 m/s (50 ft/min)
Units m/s, ft/min
Resolution 0.01 m/s (1 ft/min)
Pressure
Dierential pressure
±3735 Pa (±15 in. H maximum safe operating pressure
O); 37.5 kPa (150 in. H2O),
2
Absolute pressure 356 to 1016 mm Hg (15 to 40 in. Hg)
Accuracy
Units
Resolution
±2% of reading ±0.025 Pa H and dierential; ±2% of reading absolute in. H
O, in. Hg, Pa, hPa, kPa, mm Hg, cm Hg,
2
O, cm H2O
mm H
2
0.001 Pa H mm Hg (0.01 in. Hg) absolute
O (0.00001 in.) static and dierential; 1
2
O (±0.0001 in.) static
2
Volume
Range
Accuracy
42 to 4250 m capture hood, supply and return ±3% of reading ±12 m
>85 m Units m
Resolution 1 m
3
/h, ft3/min, l/s, m3/min
3
3
/h (25 to 2,500 ft3/min)
3
/h (>50 ft3/min)
/h (1 ft3/min)
3
/h (±7 ft3/min) at ows
Temperature
Sensor in base 4.4 to 60°C (40 to 140°F)
Temperature/RH probe -10 to 60°C (14 to 140°F)
Accuracy ±0.3°C (±0.5°F)
Units °C, °F
Resolution 0.1°C (0.1°F)
RH
Range 5 to 95% RH (temperature/RH probe)
Accuracy ±3% RH
Resolution 0.1% RH
Instrument Temperature Range
Operating 4.4 to 60°C (40 to 140°F)
Stora ge -20 to 71°C (-4 to 160°F)
Statistics
min, max, average and sum
Data Storage
26,500 samples, time and date stamped
Logging Interval
User selectable
Response Time
2 to 8 seconds, dierential pressure sensor
Power Requirements
Four AA-size cells or AC adapter
Physical Characteristics
Dimensions (micromanometer only)
Weight with Batteries
18.8 cm x 11.4 cm x 5.8 cm (7.4 in. x 4.5 in. x 2.3 in.)
PH730 0.5 kg (17 oz.) PH731 3.4 kg (7.4 lb.)
6.35 mm (1/4 in.) OD straight ports with
Pressure Connection
barbed ends for use with 4.76 mm (3/16 in.) ID exible tubing
Model EBT731-B* EBT731 EBT731-STA EBT730
Description
Basic 2 ft x 2ft (610 mm x 610 mm) EBT Balometer Capture Hood Kit
Standard 2 ft x 2ft (610 mm x 610 mm) EBT Balometer Capture Hood Kit
Bundled 2 ft x 2ft (610 mm x 610 mm) EBT Balometer Capture Hood Kit
Micromanometer
Capture hood base, poles, frame and fabric + + +
Micromanometer + + + + (4) support poles + (6) support poles + +
(4) AA alkaline batteries +
(4) AA rechargeable NiMH batteries + + +
(2) battery holders + + + +
Multi-country AC power adaptor + + +
46 cm (18 in.) pitot probe + + +
5.0 m (16 ft.) tubing + + +
(2) static pressure probes + + +
Neck strap + + +
Capture hood stand +
Android Tablet loaded with LogDat Mobile +
Wheeled carrying case + + +
Handheld carrying case +
LogDat CH downloading software with cable + + + +
User manual + + + + Calibration certicate, pressure: 5-points (dierential),
3-points (barometric), 3-points (temperature) Calibration certicate, ow: 7-points (supply), 7-points (return)
+ + + +
+ + +
*Not available in North America
Kit
Use the stand and tablet app to do single-person balancing of a system
3
Page 4
SPECIFICATIONS
EBT BALOMETER® MODEL EBT731 DETACHABLE MICROMANOMETER MODEL EBT730
Recommended Optional Accessories Probes
Hood Kits
801097 (standard) 2 ft. x 2 ft. (610 mm x 610 mm)
801200 1 ft. x 4 ft. (305 mm x 1220 mm)
801216 2 ft. x 3 ft. (610 mm x 915 mm)
801201 2 ft. x 4 ft. (610 mm x 1220 mm)
801202 1 ft. x 5 ft. (305 mm x 1525 mm)
801203 3 ft. x 3 ft. (915 mm x 915 mm)
801206
801207
801209
801210
1 ft. x 4 ft. (305 mm x 1,220 mm) and 2 ft. x 4 ft. (610 mm x 1,220 mm) 1 ft. x 5 ft. (305 mm x 1,525 mm) and 3 ft. x 3 ft. (915 mm x 915 mm)
16 in. x 16 in. (406 mm x 406 mm)
5.25 in. x 4 ft. (133 mm x 1220 mm)
801211 28 in. x 28 in. (710 mm x 710 mm)
801212
80215
28 in. x 50 in. (710 mm x 1270 mm)
1 ft. x 3 ft. (305 mm x 915 mm)
801204 (BSC*) 8 in. x 22 in. (205 mm x 560 mm)
801205 (BSC*)
* The BSC hood kits are used to certify Class II bio-safety cabinets by taking direct in-ow
measurements for NSF compliance.
10 in. x 22 in. (255 mm x 560 mm)
Duct Plugs
634650002
3/8 in. (9.5 mm) diameter - 1000 pieces
634650003 3/8 in. (9.5 mm) diameter - 5000 pieces
Printer
8934
Wireless Bluetooth printer
LogDat™ Mobile Software
LogDat Mobile
Remote reader and data logger Android App available via Google Play
Software
Capture Hood Stand
CH-Stand
Extends up to 15 ft. (4.5 m with EBT731 attached) to take readings from ceiling diuser without the use of a ladder. Capture hood is secured onto quad bracket and two extension pole sections can be raised to desired height and locked in place. Hood stand uses wheels for ease of movement and portability.
EBT731 Bundle
EBT731-STA Bundle
Includes: EBT 731 Capture Hood, Capture Hood Stand, Smart Tablet* loaded with LogDat
*TSI has the discretion to change the brand and model of tablet at any time.
Mobile App and instruction videos.
Airow Probe 800187
Straight air ow probe, 18 in. (46 cm). Used to perform a duct traverse and to measure face velocity measurements. Ideal for small diameter ductwork.
Temperature and Humidity Probe 800220
Telescopic temperature and humidity probe, extends 9-39 in. (230-990 mm). Used for measuring inside of duct work. Can be inserted into a standard 5/16 in. (8 mm) diameter hole typically use for pitot traverses with the ability to calculate wet bulb and dewpoint temperatures.
Thermoanemometer Air Velocity Probes Models 960, 962, 964, and 966
Available in straight or articulating construction, and with or without a relative humidity sensor. Models with a relative humidity sensor can also calculate wet bulb and dewpoint temperature.
Velocity Matrix 801090
16 point Telescopic Velocity Matrix. Used for measuring face velocities of HEPA lters, chemical fume hood, laminar ow benches, lter banks, kitchen exhausts and other applications where a large surface area needs to be measured. Grid covers 1 ft. velocity while minimizing the eects of
2
(0.09 m2) and averages the air
turbulence to produce a stale reading.
Pitot Probes
634634000 5/16-12 in. (8 mm – 30 cm) diameter
634634001*
634634002
5/16-18 in. (8 mm – 46 cm) diameter
5/16-24 in. (8 mm – 61 cm) diameter
634634003 5/16-36 in. (8 mm – 91 cm) diameter
634634005
5/16-60 in. (8 mm – 152 cm) diameter
*included in specic bundles. Please refer to model matrix on page 3.
Specications subject to change without notice. TSI, the TSI logo, Alnor, LogDat and Balometer are trademarks of TSI Incorporated. Android and Google Play are trademarks of Google Inc.
UNDERSTANDING, ACCELERATED
TSI Incorporated
USA Tel: +1 800 874 2811 UK Tel: +44 149 4 459200 France Tel: +33 1 41 19 21 99
- Visit our website www.tsi.com for more information.
India Tel: +91 80 67877200 China Tel: +86 10 8219 7688 Singapore Tel: +65 6595 6388
Germany Tel: +49 241 523030
P/N 5001434 Rev H ©2019 TSI Incorporated
Loading...