TSI Alnor AP800 Specifications

Page 1
UNDERSTANDING, ACCELERA
TED
AIRPRO™ MICROMANOMETER INSTRUMENTS
MOBILE APP, FEATURE SETS, AND MICROMANOMETER
AirPro™ Micromanometer Instruments are rugged, compact, congurable and highly accurate measurement devices featuring a Micromanometer (AP800), Mobile Application Software (AP-MOBILE), and Feature Sets (APFS-B, APFS-A and APFS-P).
AirPro Micromanometer Model AP800 measures static and dierential pressures with seamless connection to smart devices, utilizing Bluetooth® Low Energy (BLE). Data is shown on an integrated display on the instrument while simultaneously being communicated wirelessly, in real-time, to the AirPro Mobile Application Software running on your mobile Android or iOS handheld device.
Applications
+ HVAC commissioning and troubleshooting + Testing and balancing + Pitot tube duct traverses + Static pressure measurements + Dierential pressure measurements
Features and Benets
+ Calculates velocity when used with a pitot tube + Auto zeros pressure sensor upon instrument startup + Barbed pressure ports to securely attach tubing + High contrast display eases viewing in dimly lit areas + Measure dierential and static pressures from
-15 to +15 in. H2O (-3735 to +3735 Pa) + Long life rechargeable Li-ion battery reduces cost of ownership + Calibration certicate included
Page 2
AIRPRO MOBILE (MODEL AP-MOBILE)
APPLICATION SOFTWARE
The AirPro Mobile software supports both Android or iOS smart devices and is available in three levels of performance – Basic, Advanced and Professional.
Basic
+ Auto-connect to the instrument + Remotely display instrument measurements + Set target values + View multiple measurements simultaneously + Supports multiple languages + Display measurements in Imperial or metric units
Advanced – Includes Basic Functionality Plus:
+ Connect up to 2 instruments for simultaneous, real-time display
and data logging + Perform ow rate calculations based on user-input duct size or K-factor + Calculate wet bulb and dewpoint temperatures (probe dependent) + Log measurements to smart device + Export data with comments and photos for report generation
Professional - Includes Basic and Advanced Functionality Plus:
+ Connect up to 6 instruments for simultaneous, real-time display
and data logging + Built in duct traverse workow supporting both Equal Area
and log-Tchebyche test methods + Supports an optional SD card for use in long- or short-term
unattended data logging applications
Function
Display Multiple Measurements Simultaneously
Supports Multiple Languages
Congure For Imperial or Metric Units of Measurements
Calculate Pitot Probe Velocity
Standard or Actual Velocity Calculation
Max # of Instruments Connected to AirPro Mobile Simultaneously
Volumetric Flow Rate Calculation (Kf or Pitot Probe)
Statistics
Data Logging
Export Data
Enable Utilization of Instruments SD Card Slot for Data Storage
Graphing
Duct Traverse Application
Online Access to Calibration Certicates
AirPro Feature Sets
Basic
(APFS-B)
X X X
X X X
X X X
X X X
X X X
1 2 6
Advanced
(APFS-A)
Professional
(APFS-P)
X X
X X
X X
X X
X
X
X
X
Page 3
AIRPRO MICROMANOMETER
MODEL AP800 AND ACCESSORIES
Model AP800 Includes:
Instrument, calibration certificate, quick start guide, universal AC/DC
adapter, battery, small carrying case, service and registration cards.
Carrying Case
800535 Large carrying case; capable of holding 2 meters, 2 probes,
3 extensions plus accessories
Static Pressure Probes and Tubing Kit
800533 Static Pressure Probes and Tubing Kit; contains two static
pressure probes and two 4 ft. (1.2 m) lengths of tubing
Pitot Probes
634634000 Pitot probe (5/16” (8 mm) diameter) - 12” (30 cm)
634634001 Pitot probe (5/16” (8 mm) diameter) - 18” (46 cm)
634634002 Pitot probe (5/16” (8 mm) diameter) - 24” (61 cm)
634634003 Pitot probe (5/16” (8 mm) diameter) - 36” (91 cm)
634634005 Pitot probe (5/16” (8 mm) diameter) - 60” (152 cm)
634634004 Telescoping pitot probe - 8” to 38” (20 cm to 96 cm)
Miscellaneous
800530 External battery charger
634650002 Duct plug, 3/8” (9.5 mm) diameter - 1000 pieces
634650003 Duct plug, 3/8” (9.5 mm) diameter - 5000 pieces
Page 4
SPECIFICATIONS
AIRPRO™ MICROMANOMETER INSTRUMENTS
MODEL AP800 AND ACCESSORIES
Static / Dierential Pressure
Range1 -15 to +15 in. H2O
Accuracy ±1% of reading ±0.005 in. H2O
Resolution 0.001 in. H2O (0.1 Pa, 0.01 mm Hg)
Velocity (Pitot Probe)
Range2 250 to 15500 ft/min (1.27 to 78.7 m/s) Accuracy3 ±1.5% at 2000 ft/min (10.16 m/s) Resolution 1 ft/min (0.1 m/s)
Barometric Pressure (AP800)
Range 20.36 to 36.648 in. Hg (517.15 to 930.87 mm Hg)
Accuracy ±2% of reading
Instrument Temperature Range
Operating 40 to 113°F (5 to 45°C) Storage -4 to 140°F (-20 to 60°C)
(-28.0 to +28.0 mm Hg, -3735 to +3735 Pa)
(±0.01 mm Hg, ±1 Pa)
Display interface
Organic light-emitting diode (OLED)
0.4 in. (10 mm) digit height
External Meter Dimensions
2.1 in. x 7.1 in. x 1.6 in. (53 mm x 181 mm x 40 mm)
Meter Weight
Weight with batteries: 0.45 lbs (0.20 kg)
Power Requirements
AirPro Li-ion battery 3500 mAh AC Adapter (TSI part number 800531 only) Input 90 to 240 VAC, 50 to 60 Hz Output 5 VDC, 2A
Battery Life
32+ hours
1
Overpressure range = 7 psi (190 in. H2O, 360 mmHg, 48 kPa).
2
Pressure velocity measurements are not recommended below 1,000 ft/min (5 m/s).
3
Accuracy is a function of converting pressure to velocity. Conversion accuracy improves
when actual pressure values increase.
Specications are subject to change without notice.
Bluetooth is a registered trademark owned by the Bluetooth SIG, Inc.
AirPro is a trademark, and TSI and the TSI logo are registered trademarks of TSI Incorporated.
UNDERSTANDING, ACCELERATED
TSI Incorporated
USA Tel: +1 800 874 2811 UK Tel: +44 149 4 459200 France Tel: +33 1 41 19 21 99 Germany Tel: +49 241 523030
Printed in U.S.A.
P/N 5001805 Rev A ©2017 TSI Incorporated
- Visit our website www.tsi.com for more information.
India Tel: +91 80 67877200 China Tel: +86 10 8219 7688 Singapore Tel: +65 6595 6388