TSI EDGE 5 User Manual

THE EDGE 5
PERSONAL NOISE DOSIMETER
Features and Benets
+ Compact, 3-ounce (85 grams) unit mounts easily to the shoulder + Large display with easy-to-use interface provides crucial
information at a glance
+ Choose from three independent dosimeters that can simultaneously
measure against separate industry standards, all in one compact unit
+ MSHA, SIRA (ATEX), CSA (US/Canada) and Simtars (iECEx)
Intrinsic Safety Approvals
DESIGNED FOR EXCEPTIONAL
EASE OF USE
LED Dose Indicator
+ LED indicator can be programmed
to ash when dose level has been exceeded
+ Helps safety manager and employees
easily identify who has reached their daily maximum noise dose exposure
Three Independent Dosimeters
+ Edge 5 enables simultaneous
measurement against as many as three industry standards (ex: OSHA PEL, OSHA HC, ACGIH)
+ Saves time and cost by reducing the
need for multiple sampling surveys
Display with Lockout Ability
+ Easy-to-read design enables
workers to monitor their own noise exposure. If desired, unit can be set to inhibit display for easier testing and verication
+ Provides safety professionals the
options needed to achieve compliance
OTHER FEATURES
with hearing protection standards
Ecient Setup
+ Infrared communication port
to EdgeDock provides quick USB connection to the Detection Management Software
+ Helps safety professional easily
setup one or more Edge dosimeters
Contoured Shoulder Mount
+ Ergonomically designed and
comfortable; weighs just 3 oz
+ Lightweight and unobtrusive
design assures comfort
Intrinsic Safety Approvals
+ The Edge 5 carries intrinsic
safety approvals from MSHA, SIRA (ATEX), CSA (US and Canada) and Simtars (IECEx)
+ Monitoring can be safely performed in
potentially hazardous environments where devices must be certied
Acoustical AC-300 Calibrator
The Acoustical AC-300 Calibrator is specically designed for eld calibration of Quest sound level meters and noise dosimeters across a wide range of temperature, humidity and pressure conditions.
Features and Benets
+ Produces two signals, 250 Hz or 1,000 Hz at a sound pressure
level of 114 dB
+ Simply insert the microphone of your instrument, select the correct
signal from the one-button keypad, and calibrate
+ Conforms to the requirements of IEC 60942 (2003-01) for sound
calibrators and ANSI S1.40-2006 (R2011): Specications and Verication Procedures for Sound Calibrators
Conforms to Standards
+ Enables condent use in a wide range of
applications and conditions
+ Meets the requirements of IEC 60942 (2003)
for sound calibrators and ANSI S1.40-2006 (R2011) for sound calibrators
One-Button Simplicity
+ Single On/O/Function key assures ease
of use
+ Makes calibrations fast and trouble-free
Detection Management Software
Designed for dosimetry, sound level measurements, heat stress assessments and environmental monitoring, this advanced software helps occupational health and safety professionals:
+ Congure instrumentation and save pre-congured setups + Retrieve, download, share, and save instrument data + Create charts, tables, and reports to intuitively interpret
your measurements
+ Export and share recorded results
Designed for Ecient Operation
+ Low battery icon indicates when
replacement is needed, to help prevent service interruption
+ Auto-OFF function powers down 4 minutes
after last key press, reducing power drain and maximizing battery life (approximately 18 hours)
The software integrates with TSI Quest Detection Solutions data logging instruments and will help you improve operating eciency
SPECIFICATIONS
THE EDGE PERSONAL NOISE DOSIMETER
Functional Requirements Include
Microphone 1/4 inch prepolarized condenser (electret)
eld replaceable threaded microphone
Measuring Range 70dB - 140dB Windscreen Rugged foam permanently attached to a
threaded mount for maximum protection
Dosimeter
The Edge 5 has three independent dosimeters. Independent
Thresholds Selectable from 70dB to 90dB or none Independent
Exchange Rates 3dB, 4dB or 5dB for each dosimeter Independent
Criterion Levels From 70dB to 90dB in 1dB increments
Measurement Settings
RMS Range 70dB to 140dB Peak Range 110dB to 143dB RMS Time Response Fast or Slow RMS Weighting A, C Peak Weighting A, C, Z
(Peak is independent of the RMS dosimeter settings)
Displayed Data / Values
+ L
or LEQ + Current Date
AVG
+ Exposure + L
C-A
+ SPL + Max Level + Min Level + SEL (L
)
EP
+ Dose + Threshold (TH) + TWA + Peak Level + Upper Limit (UL) + Run Time + Identity Field + Projected Dose
(assigns a custom name to The Edge)
Displayed Status Indicators
+ Battery + Memory + Run/Pause + Overload Indication + Dose Exposure Indicator
(Multicolored LED, user selectable)
Docking Station: Single and Five Bay Versions
Communications Via the EdgeDock and USB to PC Typical Recharge 2 to 4 hours Complete Instrument Fits neatly into EdgeDock without
removing mounting device
Power / Electrical Characteristics
Battery Lithium Polymer (Flat cell) Battery Life 40 hours nominal
without LED activated
Battery Charge Quick charge in EdgeDock in 2 to 4 hours.
Daily data download with simultaneous battery charging recommended for maximum eciency
Memory Capacity 180 hours Communications Short haul serial Infrared (SIR)
via the EdgeDock
Standards
ANSI S1.25 Personal Noise Dosimeters IEC61252 Personal Sound Exposure Meters Intrinsic Safety + EN 60079-0:2013, EN 60079-11:2012,
EN 60079-26:2014 + IECEx certication number: SIM 08.0012 + ATEX Directive 2014/34/EU for use in
Potentially Explosive Atmosphere certication
number: Sira 09ATEX2269 + CSA International (US and Canada)
certicate number: 2283414 + MSHA Approval number: 18-A100008-0
Physical Characteristics
Weight 3 ounces (85 grams) Size 3.5” long x 2.1” wide x .82” thick
(88mm x 53mm x 21mm),
Case Material Engineered Polymer IP Rated 65 Keypad 4 keys – Up Arrow, Down Arrow,
Run/Stop, On/O/Enter
Display 128x64 LCD RoHS Compliant Lockable Windscreen Alligator Clothing Clip / Suspender Clasp
Environmental Characteristics
Operating Temperature Range 14 °F to 122 °F (-10 °C to 50 °C)
Storage Temperature Range -13 °F to 140 °F (-25 °C to 60 °C)
Humidity Range 0 to 95% Non-Condensing
Additional Features
Device Setup Easy, quick setup via DMS software in Chinese,
Czech, English, French, German, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Russian, Spanish, Swedish, and Turkish
Data Logging L
or LEQ, Max, Peak and Overload Indication at
AVG
one minute intervals
Calibration times displayed Lock out security function (multilevel)
TSI Incorporated
USA Tel: +1 800 874 2811 UK Tel: +44 149 4 459200 France Tel: +33 1 41 19 21 99
- Visit our website www.tsi.com for more information.
India Tel: +91 80 67877200 China Tel: +86 10 8219 7688 Singapore Tel: +65 6595 6388
Germany Tel: +49 241 523030
Printed in U.S.A.P/N 5002161 Rev C ©2020 TSI Incorporated
Specications are subject to change without notice.
Quest is a trademark, and TSI and the TSI logo are registered trademarks of TSI Incorporated.