T & S Brass & Bronze Works EC-3106 General Manual

T&S BRASS AND BRONZE WORKS, INC.
2 Saddleback Cove / P.O. Box 1088
Travelers Rest, SC 29690
REG. #A2601
ISO #9001
EC-3106
Item No.
Travelers Rest, SC: 800-476-4103
This Space for Architect/Engineer Approval
Job Name
Model Specified_____________________ Quantity______ Customer/Wholesaler______________________________ Contractor_______________________________________ Architect/Engineer_________________________________
__________________________Date_________
Simi Valley, CA: 800-423-0150
3 5/8" x 4 3/16" x 2" Deep [92mm x 106mm x 51mm] Water Resistant Control Module Box (Blue) w/ Internal Flow Control Setting Switches, AC or DC operated w/ (4) AA Batteries
24" [610mm] Sensor Cable
DECK
Fax: 864-834-3518
(Automatic Electronic
Operation Only)
[102mm]
www.tsbrass .com
Single Hole Deck Spout w/ 2.2 GPM [8.3 L/min] Vandal Resistant Aerator and Manual Bypass Operation
4 1/4"
[108mm]
7 5/16"
4"
[186mm]
2" Max.
[50mm]
18" [457mm] Long Flexible St. Steel Hoses
Removable Strainer
100-135 VAC Adapter w/ 144" [3658mm] Long Power Cord. (Remove Rubber Plugs on Module and Cable to Connect)
Furnished w/ (2) 3/8" Compression x 1/2" NPSM x 18" [457mm] Long
Temperature Mixing Valve
Flexible Stainless Steel Supply Hose
with Integral Check Valves
Supply Stops by OthersNOTE:
Product Specifications:
Chrome Plated Brass Electronic Faucet: Single Hole Deck Spout w/ VR A erator & Manual Bypass, A C /DC Control Module w/ Internal Flow Control Setting Switches, Temperature Control Mixing Valve, 18" Long Supply Stop Flexible Connector Hoses
Rough-in: 1 1/4" [32mm]
Approved
Date:
GEF
Scale:
CheckedDrawn
DMH
1:6
JHB
9/16/10
Sheet:
of
1
2
T&S BRASS AND BRONZE WORKS, INC.
2 Saddleback Cove / P.O. Box 1088
Travelers Rest, SC 29690
REG. #A2601
ISO #9001
EC-3106
Item No.
Travelers Rest, SC: 800-476-4103
6 5
Simi Valley, CA: 800-423-0150
ITEM
NO.
SALES
NUMBER
1 017493-45 2 5EF-0002
3 5EF-0006 4 5EF-0005 5 B-0199-09 6 015425-45
Fax: 864-834-3518
www.tsbrass .com
DESCRIPTION
ChekPoint Module (Blue) w/ Bypass Tee A/C Transformer Manual Mixing Valve Supply Hose, 9/16-24 Female X 1/2" NPSM VR Aerator w/ Key Vandal Resistant Key
1
3
2
Label for Flow Control Switch Settings
4
is located on Inside of Back Cover. Flow Control Switches are located
inside Module Housing in Black Box next to Battery Compartment. *Switches are set to DEFAULT position: Auto Time Out = 10 seconds Shut Off Delay = 1 second Auto Flush = OFF
Remove (4) screws and back cover to access switches.
*Available Water Flow Control Selections: (6) Auto Time Out Selections - 10 sec, 25 sec, 45 sec, 60 sec, 3 min, 20 min (4) Shut Off Delay Selections - 1 sec, 2 sec, 4 sec, 10 sec Auto Flush for 30 Seconds After Every 12 Inactive Hours - ON or OFF
Product Specifications:
Chrome Plated Brass Electronic Faucet: Single Hole Deck Spout w/ VR A erator & Manual Bypass, A C /DC Control Module w/ Internal Flow Control Setting Switches, Temperature Control
Drawn
GEF
Scale:
Mixing Valve, 18" Long Supply Stop Flexible Connector Hoses
Checked
Approved
DMH JHB
Date:
NTS
9/16/10
Sheet:
of
2
2