T&S BRASS AND BRONZE WORKS, INC.
2 Saddleback Cove / P.O. Box 1088
Travelers Rest, SC 29690
REG. #A2601
ISO #9001
Model No.
016647-45
Item No.
Travelers Rest, SC: 800-476-4103
This Space for Architect/Engineer Approval
Job Name__________________________Date_________
Model Specified_____________________ Quantity______
Customer/Wholesaler______________________________
Contractor_______________________________________
Architect/Engineer_________________________________
Simi Valley, CA: 800-423-0150
Water Resistant
Faucet Sensor
Cable Connection
(Remove Rubber Cap
to Connect Cable)
1/2 NPSM Male
Outlet
Removable
Strainer
Mixed Water Elbow
Fitting with
Integral Strainer
Fax: 864-834-3518
www.tsbrass.com
Battery Storage
Compartment Access
Cover
1 1/16"
[27mm]
2"
[51mm]
1/2 NPSM Female 360
Swivel Coupling Nut
3 5/8" x 4 3/16" x 2" Deep
Control Module Box. (Blue),
AC or DC Operated w/ (4)
AA Batteries
Water Resistant
Transformer Cable
Connection Port
(Remove Rubber Plug
to Connect Cable)
Product Specifications:
ChekPoint Sensor Faucet Control Module
with Internal Flow Control Setting Switches
(Blue Module Housing)
3 3/8"
[86mm]
2"
[51mm]
ON/OFF Button
Drawn Checked
GEF
Scale:
DMH
NTS
Approved
JHB
Date:
08/23/10
Sheet:
1
of
2
T&S BRASS AND BRONZE WORKS, INC.
2 Saddleback Cove / P.O. Box 1088
Travelers Rest, SC 29690
REG. #A2601
ISO #9001
Model No.
016647-45
Item No.
Travelers Rest, SC: 800-476-4103
Label for Flow Control Switch Settings
is Located on Inside of Back Cover.
Simi Valley, CA: 800-423-0150
Fax: 864-834-3518
www.tsbrass.com
*Available Water Flow Control Selections:
(6) Auto Time Out Selections - 10 sec, 25 sec, 45 sec, 60 sec, 3 min, 20 min
(4) Shut Off Delay Selections - 1 sec, 2 sec, 4 sec, 10 sec
Auto Flush for 30 Seconds After Every 12 Inactive Hours - ON or OFF
Product Specifications:
ChekPoint Sensor Faucet Control Module
with Interna l Flo w Control Setting Switches
(Blue Module Housing)
Flow Control Switches are located
inside Module Housing in Black Box
next to Battery Compartment.
*Switches are set to DEFAULT position:
Auto Time Out = 10 seconds
Shut Off Delay = 1 second
Auto Flush = OFF
Remove (4) screws and back cover to
access switches.
Drawn
GEF
Scale:
Checked
DMH
NTS
Approved
JHB
Date:
08/23/10
Sheet:
of
2
2