T&S BRASS AND BRONZE WORKS, INC.
2 Saddleback Cove / P.O. Box 1088
Travelers Rest, SC 29690
Travelers Rest, SC: 800-476-4103 • Simi Valley, CA: 800-423-0150 • Fax: 864-834-3518 • www.tsbrass.com
This Space for Architect/Engineer Approval
Model No.
EC-3100-7XF1THG
Item No.
2 1/2"
63mm
Job Name
Model Specified_____________________ Quantity______
2 1/4"
57mm
Customer/Wholesaler______________________________
Contractor_______________________________________
Architect/Engineer_________________________________
__________________________Date_________
3 5/8" x 4 3/16" x 2" Deep
[92mm x 106mm x 51mm]
Water Resistant Control Module Box (Grey)
w/ Internal Flow Control Setting Switches
127X-V10
Rigid Gooseneck w/
AC or DC Operated w/ (4) AA Batteries
Hardwire Capable Using Terminals on Back
VR 1.0 GPM
Female Aerator
1/2" NPSM x 1/4" NPSM
18" [457mm] Flexible
Stainless Steel Hose
13 1/4"
337mm
7 11/16"
24" [610mm]
7 5/16"
185mm
195mm
Sensor Cable
2 1/4
57mm
Maximum
Removable
Thickness
Strainer
EC-HYDROGEN
Hydro-Generator
Power Supply.
No AA Batteries or
AC Adapter Needed
to Supply Power to
Faucet
EC-TMV
Thermostatic
Temperature
Mixing Valve w/
Check Valves
Product Specifications:
Optional 100-240 VAC Adapter w/
71" [1800mm] Power Cord. (Included)
(Remove Rubber Plugs on Module
and Cable to Connect)
(2) 3/8" Compression x 1/2" NPSM
18" [457mm] Flexible Stainless Steel
Supply Hose
Chrome Plated Brass Electronic Faucet: Deck Mount, Rigid Gooseneck
w/ VR 1.0 GPM Aerator, AC/DC Control Module w/ Internal Flow Control
Setting Switches, Thermostatic Temperature Control Mixing Valve w/ Integral
Check Valves, Hydro-Generator & 18" Flexible Stainless Steel Supply Hoses
Drawn:
KJG
Checked:
JRM
Approved:
JHB
Date:
12/10/19
1/8" [3mm]
Anti-Rotation Pin.
Remove Pin if
Desired.
(See Mounting
Hole Detail)
Mounting Hole
Product Compliance:
ASME A112.18.1 / CSA B125.1
NSF 61 - Section 9
NSF 372 (Low Lead Content)
ANSI A117.1 (ADA)
UL 1951
ASSE 1070 (TMV)
Scale:
1:8
Details
1 1/8"
29mm
5/32" [4mm]
Sheet:
1 5/32"
29mm
of
12
T&S BRASS AND BRONZE WORKS, INC.
2 Saddleback Cove / P.O. Box 1088
Travelers Rest, SC 29690
Travelers Rest, SC: 800-476-4103 • Simi Valley, CA: 800-423-0150 • Fax: 864-834-3518 • www.tsbrass.com
ITEM
NO.
1 127X-V10 Rigid Gooseneck w/ VR 1.0 GPM Aerator
2 001043-45 Washer
3 B-0199-07-F10 VR 1.0 GPM Aerator, 3/8" NPSM Male w/ Key
4 044A 3/8" to Aerator Adapter
1
5 B-0199-06-F10 VR 1.0 GPM Aerator, 55/64-27 UN Female w/ Key
6 017195-45 Angled Sensor w/ Cable
2
3
4
5
7 015425-45 Vandal Resistant Key
8 5EF-0005 Supply Hose, 9/16-24 Female x 1/2" NPSM
9 EC-HYDROGEN HydroGenerator Power Supply
10 017506-45 1/2" NPSM Swivel Coupling
11 EC-FILTER Replacement Filter
12 016297-45 Inlet Hose, Faucet, 1/2" NPSM-F x 1/4" NPSM-F
13 016647-45 ChekPoint Electronic Module (Grey)
14 5EF-0002 A/C Transformer
15 EC-TMV Thermostatic Mixing Valve
SALES NO. DESCRIPTION
Model No.
EC-3100-7XF1THG
Item No.
13
12
11
6
9
A Maximum of (8) ChekPoint Faucets can
be Hardwire Connected and Powered by
EC-HARDWIRE ChekPoint Hardwire AC
Transformer. (Sold Separately)
10
14
Label for Flow Control Switch Settings
is Located on Inside of Back Cover.
7
8
15
Flow Control Switches are Located
Inside Module Housing in Black Box
Next to Battery Compartment.
*Switches are Set to DEFAULT Position:
- Auto Time Out = 15 Seconds
- Shut Off Delay = 1 Second
- Auto Flush = OFF
Remove (4) Screws and Back Cover to
Access Switches.
*Available Water Flow Control Selections:
- Auto Time Out: 15 sec, 30 sec, 45 sec, 60 sec, 3 min, 20 min
- Shut Off Delay: 1 sec, 10 sec, 15 sec, 30 sec
- Auto Flush (30 Seconds After Every 12 Inactive Hours): ON or OFF
Product Specifications:
Chrome Plated Brass Electronic Faucet: Deck Mount, Rigid Gooseneck
w/ VR 1.0 GPM Aerator, AC/DC Control Module w/ Internal Flow Control
Setting Switches, Thermostatic Temperature Control Mixing Valve w/ Integral
Check Valves, Hydro-Generator & 18" Flexible Stainless Steel Supply Hoses
Drawn: Approved:
KJG
Checked:
JRM
Date:
12/10/19 Scale:
Product Compliance:
ASME A112.18.1 / CSA B125.1
NSF 61 - Section 9
NSF 372 (Low Lead Content)
ANSI A117.1 (ADA)
UL 1951
ASSE 1070 (TMV)
NTS
of
2
Sheet:JHB
2