T&S Brass 016647-45BL User Manual

T&S BRASS AND BRONZE WORKS, INC.
2 Saddleback Cove / P.O. Box 1088
Travelers Rest, SC 29690
Model No.
016647-45BL
Item No.
Travelers Rest, SC: 800-476-4103 • Simi Valley, CA: 800-423-0150 • Fax: 864-834-3518 • www.tsbrass.com
This Space for Architect/Engineer Approval
Job Name__________________________Date_________
Model Specified_____________________ Quantity______ Customer/Wholesaler______________________________ Contractor_______________________________________ Architect/Engineer_________________________________
Water Resistant
Faucet Sensor
Cable Connection
(Remove Rubber Cap
to Connect Cable)
Battery Storage Compartment Access Cover
1/2 NPSM Male Outlet
1 1/16"
Red Cross Decal Identifies Medical Control Module
[27mm]
Removable Strainer
Mixed Water Elbow Fitting with Integral Strainer
1/2 NPSM Female 360 Swivel Coupling Nut
3 5/8" x 4 3/16" x 2" Deep Control Module Box. (Blue), AC or DC Operated w/ (4) AA Batteries. Hardwire Capable using Terminals on Back
Water Resistant Transformer Cable Connection Port (Remove Rubber Plug to Connect Cable)
3 3/8"
[86mm]
2"
[51mm]
2"
[51mm]
ON/OFF Button
Product Specifications:
ChekPoint Sensor Faucet Medical Control Module with Internal Flow Control Setting Switches (Blue Module Housing)
Drawn
GEF
Scale:
1:2
Checked
Approved
JHB
Date:
11/29/12
of
1Sheet:
2
T&S BRASS AND BRONZE WORKS, INC.
2 Saddleback Cove / P.O. Box 1088
Travelers Rest, SC 29690
Model No.
016647-45BL
Item No.
Travelers Rest, SC: 800-476-4103 • Simi Valley, CA: 800-423-0150 • Fax: 864-834-3518 • www.tsbrass.com
Label for Flow Control Switch Settings is Located on Inside of Back Cover.
EC-FILTER
*Available Water Flow Control Selections: (6) Auto Time Out Selections - 15 sec, 30 sec, 45 sec, 60 sec, 3 min, 20 min (4) Shut Off Delay Selections - 1 sec, 10 sec, 15 sec, 30 sec Auto Flush for 30 Seconds After Every 12 Inactive Hours - ON or OFF
Product Specifications:
ChekPoint Sensor Faucet Medical Control Module with Internal Flow Control Setting Switches (Blue Module Housing)
Flow Control Switches are located inside Module Housing in Black Box next to Battery Compartment. *Switches are set to position: Auto Time Out = 20 Minutes Shut Off Delay = 1 second Auto Flush = OFF
Remove (4) screws and back cover to access switches.
Drawn
GEF JHB
Scale:
Checked
NTS
Approved
Date:
11/29/12
2Sheet:
of
2
Loading...