Trycom Technology TRP-C38 User Manual

TRP-C38
User’s Manual
Ethernet To 8-Port RS232 Server
Printed MAR. 2007 Rev 1.0
Trycom Technology Co., Ltd
1F, No.2-11, Sihu street, Yingge Township, Taipei, Taiwan ROC
Tel: 886-2-86781191, Fax: 886-2-86781172
Web: www.trycom.com.tw
Copyright
Copyright Notice: The information in this manual is subject to change without prior notice in order to improve reliability , design and function and dosed not represent a commitment on the part of the manufacturer. No part of this manual may be reproduced, copied, or transmitted in any form without the prior written permission of manufacturer. Acknowledgment Products mentioned in this manual are mentioned for identification purpose only. Products manes appearing in this manual may or may not be registered trademarks or copyright of their respective companies.
cele mai sensibile
Electric Film S.R.L. Aleea Scarisoara 3, Apt.42 Cluj Napoca, Cluj 400445 www.electricfilm.eu
VÂNZĂRI 0364 710319 electricfilm.eu@gmail.com SUPORT TEHNIC 0788 250583
ECHIPAMENTE PENTRU AUTOMATIZĂRI
1 Introduction…………………………………………………………………….………….…….…….3 1-1Feature…………..………………………………………………………………….…….…….…….3 1-2 Specification………………………………………………………………………..…….…………3 2 Hardware Descriptions…………………………………………………………….…….…….…… 4 2-1 Panel Layout…………………..……..……………………………………………….……..………4 2-2 Serial Connection……………………………………………………………………………..……5 2-3 Power Connection……………………..…………………………………………………………...5 2-4 Ethernet Connection……………………..………………………………………………………...5
2-5 Reset Button.......……………………………..…………………………………………………..…5
2-6 Dip Switches.....…………………………………………………………………………………..…5
2-7 DB9 Pin Configurations….…………………………………………………………….……….…6
3 Default Settings……………………………………………………………………………….……....6
4 Install TRP-C38 Hardware………………………………………………………….. …….………...7 4-1 RS485 Wiring……..…………………………………………………………………..……………..7 4-2 RS422 Wiring…………..……………………………………………………………..……………..7 4-3 RS232 ………………..………………………………………………………………..……………..7
4-4 RJ-45 Wiring………..………………………………………………………………….………....…8
5 Install “TRP-C3X Manager” Utility……………………………………………………..…………..8 6 Updating a TRP-C38 Existing Installation……………………………………………………….10 7 How to configure TRP-C38….…………………………………………………………….………..11 7-1 Using TRP-C3X Manager………………………………………..……………………………….11 7-1-1 Searching LAN for TRP-C38………………………………………………………………..…11 7-1-2 Configuring Server Properties………………………………………………………………..12 7-2 Using Console Mode………………………………………………………..…………………….18 7-2-1 Console Mode Hardware Wiring…………………………………………………..………….18 7-2-2 Console Mode Software Install……………………………………………..………… ……...18 7-3 Using Telnet……………………………………………………………………………….……….20 7-4 Using Web Server………………..………………………………………………………………..22 8 Virtual-Com…………………………………………………………………………………………...22 8-1 Installing Virtual COM Port………………………………………………………………………23 8-2 Configuring Virtual COM Port…………………………………………….……………………..24 8-3 Uninstalling the Virtual COM Port……………………………………………………………...27 8-4 Removing the Virtual COM port with Manager Software…..……….………………………27 8-5 Removing the Virtual COM Port using Device Manager……………………………………27 9 Application……………………………………………………………………………………………28 9-1 Direct IP Mode……………………………………………………………………………………..28 9-2 Virtual COM Mode…………….…………………………………………………………………..28 9-3 Paired Mode…..……………………………………………………………………………………29 9-4 Heart Beat…..………………………………………………………………………………………29 10 Using TRPCOM Utility For Connect RS232/422/485 Device………………………………..30 11 RS232/422 Loop Test……………………………………………………………………………...31
12 Troubleshooting……………………………………………………………………………….......32
cele mai sensibile
Electric Film S.R.L. Aleea Scarisoara 3, Apt.42 Cluj Napoca, Cluj 400445 www.electricfilm.eu
VÂNZĂRI 0364 710319 electricfilm.eu@gmail.com SUPORT TEHNIC 0788 250583
ECHIPAMENTE PENTRU AUTOMATIZĂRI
2
1. Introduction
TRP-C38, a compact, 8-port serial device, is designed to instantly convert data from RS232 interfaces to a 10/100Mbps Ethernet network running at the TCP/IP protocol. By using a standard COM port and existing network infrastructure the device allow you to link together serial peripherals that are distant from one another from Windows, Linux and Unix without the need to install any specific cabling or modify existing software and industry standard DIN rail design enables fast and professional installation. The TRP-C38 operates in “Direct IP Mode”, “Virtual COM Mode”, and “Paired Mode”. It has two synchronous DB-9 serial ports, both equip 10/100 Mbps Ethernet RJ-45 connection. The Ethernet port will auto-select 10BaseT or 100BaseTX. TRP-C38 also offers a Heart Beat feature to ensure a reliable communicating connection.
1-1. Features
¾ Supports RS-232 serial interface ¾ In Server mode supports individual client sessions for security. ¾ Virtual COM drivers for Windows NT/98/ME/2000/XP ¾ Fully compatible with Ethernet and TCP/IP protocol. ¾ Supports 10/100 Mbps Ethernet ¾ Supported baud rate up to 230.4 Kbps. ¾ Power/Link/COMA ~COMH Flow mode LED indicator. ¾ Support intranet and internet system setting function. ¾ Support screw terminal and standard external DC power adaptor. ¾ Power input requirement from DC +10V to +48V.
1-2. Specification.
z Power Input Voltage: DC +10V to +30V z Serial Memory: output: 16K bytes per port
Input: 8K byte per port
z LAN: 10/100 Mbps Auto-detecting – 10/100Base T. z Serial Interfaces: RS-232 - TX, RX, RTS, CTS, DTR, DSR, DCD, GND z Data Rate: 110 bps to 230.4 k bps z Parity: none, even, odd, mark, space z Data Bits: 5, 6, 7 or 8 z Stop Bits: 1, 1.5 or 2 z Protocol: TCP, IP, ARP, DHCP, Telnet, HTTP, UDP, ICMP z Din-Rail mountable: Yes. z Power supply: Screw terminal, or standard external DC adapter. z Power consumption: 12V/500 mA. z Operating Temperature: 0 to 65 °C. z Storage Temperature: -20 to 65 °C. z Humidity: 0 – 90% Non-Condensing. z Approvals: CE, FCC. z Dimensions: 120*210*35 mm. z Weight:638g
cele mai sensibile
Electric Film S.R.L. Aleea Scarisoara 3, Apt.42 Cluj Napoca, Cluj 400445 www.electricfilm.eu
VÂNZĂRI 0364 710319 electricfilm.eu@gmail.com SUPORT TEHNIC 0788 250583
ECHIPAMENTE PENTRU AUTOMATIZĂRI
3
2. Hardware Description
The following information is provided to give the user an understanding of how to connect the TRP-C38 to the LAN and serial device. A review of the switch settings and the functionality of the LED’s are also provided.
2-1. Panel layout
A-TX/RX LED: COM-A RS232 Transiting/Receiving B-TX/RX LED: COM-B RS232 Transiting/Receiving C-TX/RX LED: COM-C RS232 Transiting/Receiving D-TX/RX LED: COM-D RS232 Transiting/Receiving E-TX/RX LED: COM-E RS232 Transiting/Receiving F-TX/RX LED: COM-F RS232 Transiting/Receiving G-TX/RX LED: COM-G RS232 Transiting/Receiving H-TX/RX LED: COM-H RS232 Transiting/Receiving DC Jack: Input from +10V to +15V.
(Pleas use the 5.5*2.1*12mm DC JACK). LINK LED:
Green – 100 Ethernet Connection. Yellow – 10 Ethernet Connection.
PWR LED: System is ready.(Blinking)
cele mai sensibile
Electric Film S.R.L. Aleea Scarisoara 3, Apt.42 Cluj Napoca, Cluj 400445 www.electricfilm.eu
VÂNZĂRI 0364 710319 electricfilm.eu@gmail.com SUPORT TEHNIC 0788 250583
ECHIPAMENTE PENTRU AUTOMATIZĂRI
4
2-2. Serial Connection The TRP-C38 has Four DB-9 male connectors. The serial port is configured as a DTE (data terminal equipment) device. All PC COM ports are DTE ports. A null modem cable is required to make a connection between the COM port on a PC and the TRP-C38 serial port. A straight through cable is required to connect the TRP-C38 serial port to a DCE device.
2-3. Power Connection The TRP-C38 has a two pins terminal block and power jack. Power can apply on either terminal block or the power jack. It accepts 10~48VDC/500mA power supply. When power is apply a red light label as run will flash every one second to indicate the system is up and running.
2-4. Ethernet Connection A straight-through Ethernet cable can be used to connect the serial server to an Ethernet hub, switch, or wall plate. A crossover Ethernet cable can be used to make a connection directly to the NIC (Network Interface Card) on a PC or laptop.
2-5. Reset Button The reset button can be found between the switch and terminal block. To reset the unit manually apply power, insert a small plastic tool, and press lightly depressing switch. Hold for 3 seconds and release. The Link and Run light will go out and turn back on. The TRP-C38 will revert to the last setting.
2-6. Dip Switches A double DIP switch allows the TRP-C38 to be placed into Console/Loop back/Default/Data Mode.
When all these switches are moved into the ON position, theTRP-C38 enters Console Mode, allowing configuration of the TRP-C38 from a PC running a terminal program such as Hyper-terminal. When the TRP-C38 enters Console Mode, the Console Mode screen will appear in the Hyper-terminal program window. The serial port settings must be 8-N-1 at 9600 baud.
When the DIP switches are switched to the ON OFF position, the TRP-C38 will work at Loop back Mode, all data is sent back immediately.
When the DIP switches are switched to the OFF ON position, the TRP-C38 will revert to its factory version firmware no matter what newer firmware has been upgraded.
cele mai sensibile
Electric Film S.R.L. Aleea Scarisoara 3, Apt.42 Cluj Napoca, Cluj 400445 www.electricfilm.eu
VÂNZĂRI 0364 710319 electricfilm.eu@gmail.com SUPORT TEHNIC 0788 250583
ECHIPAMENTE PENTRU AUTOMATIZĂRI
5
When all of the DIP switches are switched back to the OFF position, the TRP-C38 will enter Data Mode (RS-232, RS-422 or RS-485).
2-7. DB9 Pin Configuration
Pin RS-232 1 DCD 2 RXD 3 TXD 4 DTR 5 GND 6 DSR 7 RTS 8 CTS 9 RI
3. Default Settings
Model Number: TRP-C38
Password: Blank DHCP: Disable IP address: 192.168.1.1 Netmask: 255.255.255.0 Gateway : 192.168.1.254 Version & Date: Current firmware version number and date Serial port: 2 Baud rate: 9600 Data/Stop bits: 8-1 Parity: None Flow control: None Protocol: TCP Serial timeout: 0 seconds TCP alive timeout: 0 minutes Connection mode: Server Delimiter HEX 1: 00 Delimiter HEX 2: 00 Force transmit: 0 ms Serial port mode: Console Maximum connection: 1 Remote IP address: 255.255.255.255
cele mai sensibile
Electric Film S.R.L. Aleea Scarisoara 3, Apt.42 Cluj Napoca, Cluj 400445 www.electricfilm.eu
ECHIPAMENTE PENTRU AUTOMATIZĂRI
VÂNZĂRI 0364 710319 electricfilm.eu@gmail.com SUPORT TEHNIC 0788 250583
6
4. Install TRP-C38 Hardware
STEP1: Connect power source with TRP-C38, if power properly supplies the PWR LED will
blinking.
Warning: User can only choose one of 2 power source, external DC-Jack or Screw terminal DC input. Do not use external DC-Jack and screw terminal DC input simultaneously.
STEP2: Connect TRP-C38 with internet port (Ethernet Hub or Switch) by RJ45 LAN cable.
If the cable properly connects the “LINK” LED will light up. Green: 100MB Yellow: 10MB
STEP3: Connect TRP-C38 with RS232 or RS422/485 serial device.
4-1. RS232 Wiring
The RS-232 supports 8 channels plus Signal Ground and is configured as DTE like a computer. Signals are single ended and referenced to Ground. To use handshaking, Flow Control must be set to RTS/CTS during Configuration. Refer to the Pin out table for connections.
4-2. RJ-45 LAN Cable Wiring Diagram
PC To TRP-C38: Please use crossover Ethernet cable. HUB To TRP-C38: Please using straight through cable
cele mai sensibile
Electric Film S.R.L. Aleea Scarisoara 3, Apt.42 Cluj Napoca, Cluj 400445 www.electricfilm.eu
VÂNZĂRI 0364 710319 electricfilm.eu@gmail.com SUPORT TEHNIC 0788 250583
ECHIPAMENTE PENTRU AUTOMATIZĂRI
7
5. Install “TRP-C3X Manager” Utility
It is recommended the user install the “TRP-C3X Manager” utility software and do a search for all TRP-C38 connected to the LAN. When this is completed a window will list the devices making them available for configuration.
Configuring the serial server to meet your LAN and application requirement is an easy process with the available setup menu in the “TRP-C3X Manager” software.
5-1. How to install TRP-C3X manager The following procedure installs the “TRP-C3X Manager” software.
STEP1. Inserting TRP-Series CD, in the CD-ROM and select the TRP-C38 Directory.
Run start.exe.
STEP2. The Install Shield Wizard window automatically display and start the setup procedure.
STEP3. Click the “Next” to continue the installation.
cele mai sensibile
Electric Film S.R.L. Aleea Scarisoara 3, Apt.42 Cluj Napoca, Cluj 400445 www.electricfilm.eu
VÂNZĂRI 0364 710319 electricfilm.eu@gmail.com SUPORT TEHNIC 0788 250583
ECHIPAMENTE PENTRU AUTOMATIZĂRI
8
STEP4. In the Choose Destination Location window select “Next” to install the “TRP-C3X Manager” software in the default location. (User may select “Browse” to install into
a selected directory)
The installation progress will be shown until complete.
STEP5. Click “Finish” when the Install Shield Wizard Complete screen appears. When the installation is complete user may access to the Manager software in the program files. If loaded in the default location Go to Start/Programs/Trycom/TRP-C3X Manager to open.
6. Updating an Existing Installation
If an older version of the Manager software is already installed, the Modify, repair or remove the program window will appear when the installation process is initiated. The recommended procedure is to remove all installed components first. Once the software has been removed, install the new software.
cele mai sensibile
Electric Film S.R.L. Aleea Scarisoara 3, Apt.42 Cluj Napoca, Cluj 400445 www.electricfilm.eu
VÂNZĂRI 0364 710319 electricfilm.eu@gmail.com SUPORT TEHNIC 0788 250583
ECHIPAMENTE PENTRU AUTOMATIZĂRI
9
Highlight remove.
7. How to configure TRP-C38
There are 4 ways to access the Server Properties and program the TRP-C38
1. TRP-C3X Manager software, see 7-1.
2. Console mode, see 7-2.
3. Telnet, see 7-3.
4. Web Server, see 7-4.
7-1. Using TRP-C3X Manager Software
The “TRP-C3X Manager” software performs several functions:
A: Searching for TRP-C38 connected to the network B: Displaying and changing the configuration of TRP-C38 C: Installing virtual COM ports on a computer D: Displaying and configuring virtual COM ports E: Uninstalling virtual COM ports on a computer F: Upgrading the TRP-C38 firmware G: Monitoring Port Status H: Saving and Loading Configuration Files
7-1-1.Searching LAN for TRP-C38
Once TRP-C38 is connected to the LAN the TRP-C3X Manager software will search it and display it in a window by name and IP address.
cele mai sensibile
Electric Film S.R.L. Aleea Scarisoara 3, Apt.42 Cluj Napoca, Cluj 400445 www.electricfilm.eu
A. Select “TRP-C3X Manager” Utility in the program file menu. If the default location was
ECHIPAMENTE PENTRU AUTOMATIZĂRI
VÂNZĂRI 0364 710319 electricfilm.eu@gmail.com SUPORT TEHNIC 0788 250583
10
Loading...
+ 22 hidden pages